Harman Stove Company Harman Clarity 828i Installation & Operating Manual Download Page 5

5

Installation

Due  to  high  temperatures,  the  Clarity  828I

Vented Gas Fireplace Insert should be located
out of traffic and away from furniture and drap-
eries.

Children and adults should be alerted to the

hazards  of  high  surface  temperatures  and
should stay away to avoid burns or clothing
ignition.

Young children should  be carefully super-

vised when they are in the same room as the
Clarity 828I Fireplace Insert.

Clothing or other flammable materials should

not be placed on or near the Clarity 828I.

S urveiller  les  enfants.  Garder  les
vêtements,  les  meubles,  l'essence  ou
autres liquides à vapeur inflammables lin
de l'appareil.

Unit to sidewall or
combustible trim .......................... 10" (254  mm)

Unit to mantel and
combustible trim,  unprotected.. 12" (305  mm)

In  addition  to these  clearances,  adequate  acces-

sibility clearance for servicing and proper operation
must be maintained.

Do  not  in  any  way  obstruct  the  combustion  air

inlets that are located on the front of the heater.

If the unit is to be installed on carpeting, vinyl, or

other  combustible  material  other  than  wood  floor-
ing,  the  appliance  shall  be  installed  on  a  metal  or
wood  panel  extending  the  full  width  and  depth  of
the  appliance.

PRELIMINARY  STEPS  TO  PREPARE  FOR
THE INSTALLATION OF THE CLARITY FIRE-
PLACE  INSERT

CLEARANCES

The following clearances to combustibles must be

observed:

Clearance from  unit to sidewall  or combustible
trim

10"

Clearance from top of unit to mantel
and combustible trim, unprotected

12"

10"

W

A

L

L

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Summary of Contents for Harman Clarity 828i

Page 1: ...FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATION INSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILDING DEP...

Page 2: ...ne or other flammable vapors and liquids in the vicinity of this or any other appliance ADVETISSEMENT Quinconque ne re spect pas la lettre les instructions dans le pr sent manuel risque de d clencher...

Page 3: ...ION 11 How to Light the Fire 11 How to Turn Off the Fire 12 MAINTENANCE 12 Removing the Glass 12 Replacing the Gasket 12 Inspecting the Venting 13 Cleaning the Glass 13 Cleaning the Log Set and Firebo...

Page 4: ...ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE S ASSURER QUE LE BR LEUR ET LE COMPARTIMENT DES COMMANDES SONT PROPRES VOIR LES INSTRUCTIONS D INSTALLATION ET D UTILISATION QUI AC...

Page 5: ...o sidewall or combustible trim 10 254 mm Unit to mantel and combustible trim unprotected 12 305 mm In addition to these clearances adequate acces sibility clearance for servicing and proper operation...

Page 6: ...d vent safety switch which will shut down the main burner if the heater is not properly venting The safety switch will automatically reset after the heater has cooled down The switch will continue to...

Page 7: ...the front is disengaged Lift the glass door slightly and remove it from the stove Set the glass door aside in a safe place where it will not be damaged WARNING Do not abuse the glass on the Clarity Fi...

Page 8: ...unds from entering into the gas train apply compounds only to the male pipe threads and only to the first two threads CAUTION TEST ALL JOINTS FOR LEAKS PROPANE NATURAL Inlet Log Positions When Assembl...

Page 9: ...r for the length of the wire RECOMMENDED WIRE GAUGES Maximum Wire Length Gauge 100 14 60 16 40 18 25 20 15 22 INSTALLING THE INSERT BEFORE OPERATING Gas Pressure Requirements Correct gas pressure and...

Page 10: ...re according to the directions on page 11 and allow the heater to burn for approximately 15 minutes The flames will increase in length and become more yellow in color as the unit heats up Three adjust...

Page 11: ...gas control knob slightly and turn it clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in slightly Do not force it 6 Wait five 5 minutes to clear out any gas If yo...

Page 12: ...he latches that secure the door frist remove the two side trim panels Each is held in place by a magnet at the bottom and a magnet at the top Remove the left side trim panel first by pulling the top s...

Page 13: ...ragile a vacuum cleaner may be used on the firebox If at any time the logs cannot be removed or installed without forcing the cause must be found The logs must never be forced Follow this sequence 1 R...

Page 14: ...justers Right Trim Panel Blower Speed Switch Right Wing Top Trim Panel Top Wing Right Wing Right Trim Panel Valve Door Ait Inlet Grill Remove to connect thermostat Cord Channel Optional Sunrise Gold F...

Page 15: ...page 12 2 Disconnect the electrical connections and the gas line fitting from the module 3 Remove the cross log the front logs and the two ember strips following the directions on page 7 4 Pull the mo...

Page 16: ...ON AND IN AC CORDANCE WITH THE CURRENT EDITION OF THE REQUIREMENTS OF THE CAN CGA B141 1 OR CAN CGA B141 2 INSTALLATION CODES LA CONVERSION DOIT ETRE EFFECTU E CONFORM MENT AUX R GLEMENTATION PROVINCI...

Page 17: ...rd so that it disengages lift the front edge up then remove it 8 Remove the center burner 9 Remove the front burner 10 Remove the 1 4 20 fasteners and retainer clip that secure the rear burner then re...

Page 18: ...hen installed must be electrically groundedin accordance with localcodes or in the absence oflocalcodes with thecurrent edition of the NationalElectrical Code ANSI NFPA 70in the United States orthecur...

Page 19: ...ner Tube 3 40 08225 29 Rear Burner Tube 3 40 08226 30 Burner Plate 1 10 08577 31 1 4 20x5 8SelfTap 3 30 1252006216 32 Burner Retainer 2 00 4211 33 1 4 20x1 bolt 3 30 1252010013 34 AirDeflector 1 10 08...

Page 20: ...20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Burner Assembly...

Page 21: ...21 36 35 37 40 43 44 41 42 45 39 51 47 48 49 50 55 52 53 58 59 60 61 62 64 57 46 56 54 38 63 65...

Page 22: ...old Pressure in w c kPa 1 7 0 42 5 9 1 47 Minimum Inlet Pressure in w c kPa 5 0 1 25 11 0 2 74 Maximum Output Btu hr 0 1370 m 27 600 28 400 AFUE seasonal efficiency minimum venting 64 9 67 0 Steady St...

Page 23: ...d Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or bat...