Cleaning  the  Heat  Exchanger

System

1.

 Remove brick panel and flame guide. See Pg 22.

2.

 Remove the ash pan. See Page 19.

3.

 Remove flue baffles located on each side of

the burnpot, see Fig. 49 & 50. The baffle is held in
place by inserting the tab into the slot (located
toward the outside of the firebox) and resting it on
the hook tab located beside the burnpot.

4. 

Pull the pointed end of the baffle slightly front

with one hand while pushing up from below with
the other hand. See Fig. 50.

5.

 W ith the baffle released from the tabs, rotate

the pointed  end toward  the door  opening. Lift
baffle up and out.
The right and left baffle are interchangeable.

6.

 Now remove the heat exchanger baffle plates.

See Fig. 51 & 52. To remove the left plate, slide
the center lock to the right. To remove the right
plate, slide the center lock to the left. (The right
and left plates are interchangeable.)
This will allow access to all of the rear vertical heat
exchanger surfaces.

7.

 W ith all four baffle plates removed, cleaning can

be performed with the arrow end of the scraper.
See Fig. 53.

8. 

Scrape all of the heat exchanger surfaces. (Be

sure to clean any internal ledges where fly ash
could have collected.)

Top Accordian
Heat Exchangers

Rear Firewall
Heat Exchanger

Fig. 49

Fig. 50

Fig. 51

Fig. 52

Fig. 53

Tab

Slot

Maintenance - Heat Exchanger

Center Lock

Center Lock

Hook Tab

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Summary of Contents for Advance Pellet Stove

Page 1: ...AFETY FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATIONINSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILDIN...

Page 2: ...dvance Igniter Automatic Ignition System allow the unit to burna large variety of biomass fuels with varyingash content The Advance feed systemhas a maximum feed rate of 6 lbs per hour and a minumum m...

Page 3: ...lly on 4 can be increased if higher burn rates are necessary The unit s maximum burn rate should not create less than 1 of ash on the burn pot front edge See Fig 2 Page 4 Overfeeding is not a safety c...

Page 4: ...ed rate setting that works well use that setting Remember if your feed rate is too high you may waste fuel 5 This is usually a weekly maintence procedure Cleaning the burn pot with the scraper with a...

Page 5: ...at the fire willnot go out as the roomtemperature goes above the control board setting The unit can only go to low burn and will remain there until it runs out of fuel or until more heat is needed and...

Page 6: ...n With the unit burning in AUTO turn to Stove Mode and putthe fan on H Set the Temperature Dial to 7 Allow the unit to burn for about 30 minutes andcheck ash on frontof burn pot Fig 5 If the ash line...

Page 7: ...e Troubleshooting section for more details A six blink status may be set if the stove is allowed to run out of pellets To reset turn mode selector to OFF then back on to the desired mode If the unit w...

Page 8: ...icing Please take this into account when plac ing the stove Mobile Home Installation AFTER THE INSTALLATION IS COMPLETED Before the first fire is lit check and record the high and low draft reading nu...

Page 9: ...s holding each rear shield Using a 5 16 nut driver or socket loosen the 2 screws about 4 or 5 turns Figure 12 Slide the rear shields straight outward until the ends come out of the rear retaining clip...

Page 10: ...on fan blade change can be made by an authorized Harman Dealer These changes must be done with the use of a draft meter These changes affect the low and high burn rate air to fuel ratios A simple draf...

Page 11: ...25 feet from the unit or in another room are not recommended It is recommended that the room sensor be installed even if only installed on the rear of the unit as a return air sensor The roomsensor i...

Page 12: ...nd is not creating a negative pressure in the house Outside Air Outside air is optional except in mobile homes and where building codes require The benefit of outside air is mainly noticed in small ve...

Page 13: ...his method provides excellent venting for nor mal operation and allows the stove to be installed clos est to the wall One inch from the wall is safe how ever two or three inches allows better access t...

Page 14: ...s in method 6 4 Installing into an existing fireplace chimney US only This method can be used for normal operation This method also provides natural draft in the event of a power failure The damper ar...

Page 15: ...vent pipe fittings Seal pipe joints with silicone in addition to the sealing system used by the manufac turer Pipe size should be increased to 4 using this method 6 Installing into an existing chimne...

Page 16: ...nt pipe 7 Installing through the ceiling vent Through the ceiling vent follow PL vent manufacturer s recommendations when using wall and ceiling pass through Flashing Stormcollar 12 min 3 min 3 min Fi...

Page 17: ...from the horizontal center line of the regulator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J The clearance to a non mechanical air sup ply inlet to the building...

Page 18: ...should be done in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 DO NOT INSTALL IN SLEEPING ROOM WARNING KEEP COMBUSTIBLES AWAY FROM FLUE OUTLET CAUTION CAUTION THE ST...

Page 19: ...ash fines behind the ash pan This space behind the ash pan was designed to allow the fines to fall out of the vertical heat exchangers and collect where they are easily cleaned out rather than going...

Page 20: ...end of the door while in the open position If thedoor is goingto be openedfor anextendedperiod of time it is suggested that it be removed see Fig 36 and set safely aside 3 Inspect the door gasket and...

Page 21: ...hese connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the rear of the feeder body Not coiled inside the burn pot...

Page 22: ...of the burn pot Figure 44 Slide the brick panel into the left corner of the fireboxwith the panel resting on the top edges of theburn pot Rotatetheright sideofthe brick panel through the dooropening...

Page 23: ...rearflue tube Figure 46 Rotate the retainercoverhandle counter clockwise upward as far as it will go approximately90o Figure 47 Hold the intake coverhandle and pull until the side of thecover at ther...

Page 24: ...ng Lift baffle up and out The right and left baffle are interchangeable 6 Now remove the heat exchanger baffle plates See Fig 51 52 To remove the left plate slide the center lock to the right To remov...

Page 25: ...s too low for proper combustion the switch opens cuttin power to the feeder mo tor and the igniter element This switch is connected into the AC high voltage wires therefore the control may show the fe...

Page 26: ...too low 3 Something is restricting fuel flow 4 Feed motor or draft motor has failed 5 Power failure or blown fuse SMOKE IS VISIBLE COMING OUT OF VENT 1 Air fuel ratio is too rich A Feed rate too high...

Page 27: ...nches Fuse Rating 6 amp BTU Range 0 to 48 000 Feed Rate 1 0 lbs hr on minimum 6 lbs hr on maximum Flue Size 3 inch Pellet Vent Pipe Maximum Wattage 480 Watts Start cycle and test Start Cycle Wattage 3...

Page 28: ...28 Advance Wiring Diagram...

Page 29: ...29 Advance Feeder Assembly...

Page 30: ...l 3 00 06641 Front Glass 3 40 08728 Side Glass 2 3 40 08729 Hopper Lid Knob 3 43 02000 View Door Frame 3 43 06613 Gold 4 Black Nickel 5 Grill 3 43 06642 Gold 4 Black Nickel 5 Glass Divider Trim Black...

Page 31: ...but not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filter...

Reviews: