17

Venting

Requirements  for  Terminating  the

Venting

WARNING: Venting  terminals must  not  be re-

cessed into a wall or siding.

NOTE: Only PL vent pipe wall pass-throughs and

fire stops should be used when venting through com-
bustible  materials.

NOTE: Always take into consideration the effect

the prevailing wind direction or other wind currents will
cause with flyash and /or smoke when placing the ter-
mination.

In addition, the following must be observed:

A. The clearance above grade  must be a mini-

mum of  18".

1

B. The clearance to a window or door that may

be opened must be a minimum of 48" to the side, 48"
below  the  window/door,  and  12"  above  the  window/
door.

1

with outside air installed, 18” 

)

C. A 12"  clearance to a permanently closed win-

dow   is   recommended  to  prevent condensation on
the  window.

D. The vertical clearance to a ventilated soffit lo-

cated above the terminal within a horizontal distance
of 2 feet (60 cm) from the center-line of the terminal
must be a minimum of 18".

E. The clearance to an unventilated soffit  must

be a minimum of 12".

F. The clearance to an outside corner is 11" from

center of pipe.

G. The clearance to an inside corner is 12".
H.  A vent must not be installed within 3 feet (90

cm) above a gas meter/regulator assembly when mea-
sured from the horizontal center-line of the regulator.

1

I. The clearance to service regulator vent outlet

must be a minimum of 6 feet.

1

J. The clearance to a non-mechanical air sup-

ply inlet to the building or the combustion air inlet to

any other appliance must be a minimum of 48”.

1

K.  The  clearance  to  a  mechanical  air  supply

inlet must be a minimum of 10 feet.

1

(

with outside air installed, 6 feet 

)

L. The clearance above a paved sidewalk or a

paved driveway located on public property must be
a minimum of  7 feet.

1,2

 

M. The clearance under a veranda, porch, deck

or balcony must be a minimum of 12 inches.

1,3

NOTE:  The clearance to vegetation and other

exterior combustibles such as mulch is 36” as mea-

sured from the center of the outlet or cap. This 36”

radius  continues  to  grade  or  a  minimum  of  7  feet
below the outlet.

1

Certain Canadian and or  Local codes or regu-

lations may require different clearances.

2

A vent shall not terminate directly above a side-

walk  or  paved  driveway  which  is  located  between
two  single   family  dwellings  and  serves  both  dwell-
ings.

3

Only permitted if veranda, porch, deck, or bal-

cony is fully open on a minimum of  2 sides beneath
the floor.

V

A

= Vent terminal

= Air supply inlet

Fixed

Closed

Openable

Openable

Fixed

Closed

I nsid e

Co rn er

De ta il

= Area where  terminal  is not  permitted

NOT E:  Where  passa ge  t hrough  a  w all,  or
partition of combustible construction is desired,
the installation shall conform to CAN/CSA-B365.
(if in  Canada)

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Summary of Contents for Advance Pellet Stove

Page 1: ...AFETY FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATIONINSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILDIN...

Page 2: ...dvance Igniter Automatic Ignition System allow the unit to burna large variety of biomass fuels with varyingash content The Advance feed systemhas a maximum feed rate of 6 lbs per hour and a minumum m...

Page 3: ...lly on 4 can be increased if higher burn rates are necessary The unit s maximum burn rate should not create less than 1 of ash on the burn pot front edge See Fig 2 Page 4 Overfeeding is not a safety c...

Page 4: ...ed rate setting that works well use that setting Remember if your feed rate is too high you may waste fuel 5 This is usually a weekly maintence procedure Cleaning the burn pot with the scraper with a...

Page 5: ...at the fire willnot go out as the roomtemperature goes above the control board setting The unit can only go to low burn and will remain there until it runs out of fuel or until more heat is needed and...

Page 6: ...n With the unit burning in AUTO turn to Stove Mode and putthe fan on H Set the Temperature Dial to 7 Allow the unit to burn for about 30 minutes andcheck ash on frontof burn pot Fig 5 If the ash line...

Page 7: ...e Troubleshooting section for more details A six blink status may be set if the stove is allowed to run out of pellets To reset turn mode selector to OFF then back on to the desired mode If the unit w...

Page 8: ...icing Please take this into account when plac ing the stove Mobile Home Installation AFTER THE INSTALLATION IS COMPLETED Before the first fire is lit check and record the high and low draft reading nu...

Page 9: ...s holding each rear shield Using a 5 16 nut driver or socket loosen the 2 screws about 4 or 5 turns Figure 12 Slide the rear shields straight outward until the ends come out of the rear retaining clip...

Page 10: ...on fan blade change can be made by an authorized Harman Dealer These changes must be done with the use of a draft meter These changes affect the low and high burn rate air to fuel ratios A simple draf...

Page 11: ...25 feet from the unit or in another room are not recommended It is recommended that the room sensor be installed even if only installed on the rear of the unit as a return air sensor The roomsensor i...

Page 12: ...nd is not creating a negative pressure in the house Outside Air Outside air is optional except in mobile homes and where building codes require The benefit of outside air is mainly noticed in small ve...

Page 13: ...his method provides excellent venting for nor mal operation and allows the stove to be installed clos est to the wall One inch from the wall is safe how ever two or three inches allows better access t...

Page 14: ...s in method 6 4 Installing into an existing fireplace chimney US only This method can be used for normal operation This method also provides natural draft in the event of a power failure The damper ar...

Page 15: ...vent pipe fittings Seal pipe joints with silicone in addition to the sealing system used by the manufac turer Pipe size should be increased to 4 using this method 6 Installing into an existing chimne...

Page 16: ...nt pipe 7 Installing through the ceiling vent Through the ceiling vent follow PL vent manufacturer s recommendations when using wall and ceiling pass through Flashing Stormcollar 12 min 3 min 3 min Fi...

Page 17: ...from the horizontal center line of the regulator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J The clearance to a non mechanical air sup ply inlet to the building...

Page 18: ...should be done in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 DO NOT INSTALL IN SLEEPING ROOM WARNING KEEP COMBUSTIBLES AWAY FROM FLUE OUTLET CAUTION CAUTION THE ST...

Page 19: ...ash fines behind the ash pan This space behind the ash pan was designed to allow the fines to fall out of the vertical heat exchangers and collect where they are easily cleaned out rather than going...

Page 20: ...end of the door while in the open position If thedoor is goingto be openedfor anextendedperiod of time it is suggested that it be removed see Fig 36 and set safely aside 3 Inspect the door gasket and...

Page 21: ...hese connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the rear of the feeder body Not coiled inside the burn pot...

Page 22: ...of the burn pot Figure 44 Slide the brick panel into the left corner of the fireboxwith the panel resting on the top edges of theburn pot Rotatetheright sideofthe brick panel through the dooropening...

Page 23: ...rearflue tube Figure 46 Rotate the retainercoverhandle counter clockwise upward as far as it will go approximately90o Figure 47 Hold the intake coverhandle and pull until the side of thecover at ther...

Page 24: ...ng Lift baffle up and out The right and left baffle are interchangeable 6 Now remove the heat exchanger baffle plates See Fig 51 52 To remove the left plate slide the center lock to the right To remov...

Page 25: ...s too low for proper combustion the switch opens cuttin power to the feeder mo tor and the igniter element This switch is connected into the AC high voltage wires therefore the control may show the fe...

Page 26: ...too low 3 Something is restricting fuel flow 4 Feed motor or draft motor has failed 5 Power failure or blown fuse SMOKE IS VISIBLE COMING OUT OF VENT 1 Air fuel ratio is too rich A Feed rate too high...

Page 27: ...nches Fuse Rating 6 amp BTU Range 0 to 48 000 Feed Rate 1 0 lbs hr on minimum 6 lbs hr on maximum Flue Size 3 inch Pellet Vent Pipe Maximum Wattage 480 Watts Start cycle and test Start Cycle Wattage 3...

Page 28: ...28 Advance Wiring Diagram...

Page 29: ...29 Advance Feeder Assembly...

Page 30: ...l 3 00 06641 Front Glass 3 40 08728 Side Glass 2 3 40 08729 Hopper Lid Knob 3 43 02000 View Door Frame 3 43 06613 Gold 4 Black Nickel 5 Grill 3 43 06642 Gold 4 Black Nickel 5 Glass Divider Trim Black...

Page 31: ...but not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filter...

Reviews: