background image

Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de

Summary of Contents for Powerplant Junior

Page 1: ...Powerplant Junior Power Supply User Manual ...

Page 2: ...Thomann GmbH Hans Thomann Straße 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 Internet www thomann de 13 09 2022 ID 264101 V3 ...

Page 3: ...ther information 6 1 2 Symbols and signal words 6 2 Safety instructions 8 3 Installation and starting up 10 4 Components and functions 14 5 Technical specifications 15 6 Protecting the environment 17 Table of contents Powerplant Junior 3 Power Supply ...

Page 4: ...4 Powerplant Junior Power Supply ...

Page 5: ...ailable to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development We there fore reserve the right to make changes without notice Please refer to the latest version of the user manual which is ready for download under www thomann de General information Powerplant...

Page 6: ... interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultation please contact our technical hotline Service If you have any problems with the device the customer service will gladly assist you 1 2 Symbols and signal words In this section you will find an overview of the meaning of symbols and sign...

Page 7: ... death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damage if it is not avoided Warning signs Type of danger Warning high voltage Warning danger zone General information Powerplant Junior 7 Power Supply ...

Page 8: ...only if they are supervised or instructed by a person who is responsible for their safety Safety DANGER Danger for children Ensure that plastic bags packaging etc are disposed of properly and are not within reach of babies and young children Choking hazard Ensure that children do not detach any small parts e g knobs or the like from the unit They could swallow the pieces and choke Never let childr...

Page 9: ...nside can damage the unit When operated in harmful ambient conditions dust smoke nicotine fog etc the unit should be maintained by qualified service personnel at regular intervals to prevent overheating and other malfunction NOTICE Power supply Before connecting the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a resi...

Page 10: ...vely Create all connections while the device is not connected to the mains Use the supplied cables for all connections The following cable types are available n 5 standard cables 1 1 length 30 cm each to supply one effects pedal n 5 standard cables 1 1 length 60 cm each to supply one effects pedal n 1 Y cable to supply one effects pedal with higher power consumption n 1 serial cable to supply a ma...

Page 11: ...r supply input of an effects pedal the other plug to a 9 V output socket of the power supply In order to avoid an overload of the power supply the current draw of each connected pedal must not exceed 120 mA 1 1 Wiring Installation and starting up Powerplant Junior 11 Power Supply ...

Page 12: ... the plug pair of the Y cable to two 9 V output sockets of the power supply In order to avoid an overload of the power supply the current draw of the effects pedal must not exceed 240 mA Y cable for devices with higher power consumption Installation and starting up 12 Powerplant Junior Power Supply ...

Page 13: ...ower supply input of the effects pedals the input plug of the cable to a 9 V output socket of the power supply The total current draw of all effects devices connected via the serial cable must not exceed 120 mA thus leaving a maximum of 24 mA to each effects pedal when using devices of the same kind Serial cable Installation and starting up Powerplant Junior 13 Power Supply ...

Page 14: ...4 Components and functions 1 5 Output sockets for 9 V 6 Red control light Indicates that the device is connected to the power supply Components and functions 14 Powerplant Junior Power Supply ...

Page 15: ...oltage 230 V 50 Hz Current consumption 30 mA Power consumption 1 54 W Output voltage 5 9 V DC Dimensions W H D 116 mm 38 mm 77 mm Weight 920 g Ambient conditions Temperature range 0 C 40 C Relative humidity 20 80 non condensing Technical specifications Powerplant Junior 15 Power Supply ...

Page 16: ...9 V yes 12 V no 18 V no Other secondary voltage no DC AC current AC DC Multi power supply yes Further information Technical specifications 16 Powerplant Junior Power Supply ...

Page 17: ... and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste Dispose of this device through an approved waste disposal firm or through your local waste facility When discarding the device comply with the rules and regulations that apply in your country I...

Page 18: ...Notes 18 Powerplant Junior Power Supply ...

Page 19: ......

Page 20: ...Musikhaus Thomann Hans Thomann Straße 1 96138 Burgebrach Germany www thomann de ...

Reviews: