9
3. LEAK TESTING
Open the gas control valve on the cylinder. Check for leaks by brushing a solution 1/2 water
and 1/2 soap over all gas system joints, including all valve connections, hose connections
and regulator connections. DO NOT USE AN OPEN FLAME to test for leaks at anytime. If
bubbles form over any of the joints, there is a leak. Turn off the gas supply and re-tighten all
joints. If bubbles form again, do not use the Jet-Pro Cooker. Please contact the customer
service line on 1300 799 787. Check for leaks annually or whenever the hose and regulator
are disconnected from the gas cylinder.
C.
INSTALLATION
1. CHOOSING A LOCATION
This Jet-Pro Cooker is for outdoor use only and should be placed in a well-ventilated
area. Take care to ensure that the Minimum clearances: From sides: 1000mm, From back:
1000mm, From above (vertical): 1000mm.
Keep this Jet-Pro Cooker away from any flammable materials!
2. OTHER PRECAUTIONS
Do not obstruct any of the ventilation openings in the Jet-Pro Cooker body. Also, position
the gas supply cylinder on level ground next to the Jet-Pro Cooker and safely away from
any source of heat. Should you need to change the gas cylinder, confirm that the cylinder
is off, and that there are no sources of ignition (cigarettes, open flame, sparks, etc.) near
before proceeding. Be sure to inspect the gas hose and ensure it is free of any twisting or
tension. The hose should hang freely with no bends, folds, or kinks, which could obstruct
the free flow of gas. Apart from the connection point, no part of the hose should touch any
hot parts. Inspect the hose before use. If the hose is damaged, it must be replaced with a
hose from the manufacturer. The length shall not exceed 1.5m. Should minimum clearances
not be adhered to severe flare up may be experienced due to a lack of airflow around the
Jet-Pro Cooker, thus voiding manufacture’s warranty.
FOR STORAGE AND CYLINDER EXCHANGE,
DISCONNECT THE CYLINDER ONLY.
DO NOT DISCONNECT HOSE FROM APPLIANCE.