THIS APPLIANCE HAS A PILOT, WHICH MUST BE LIT BY HAND. WHEN LIGHTING THE PILOT, FOLLOW THESE
INSTRUCTIONS EXACTLY. BEFORE LIGHTING, SMELL ALL AROUND THE APPLIANCE AREA FOR GAS. BE
SURE TO SMELL NEXT TO THE FLOOR BECAUSE SOME GASES ARE HEAVIER THAN AIR AND WILL SETTLE
ON THE FLOOR.
BASIC OPERATION
1.
Knob is for manual pilot, on-off function. Turn knob counterclockwise to the “PILOT” position and depress knob to
allow flow of the pilot gas to the pilot burner.
See Figure 2
*
USE ONLY YOUR HAND TO TURN OR PUSH IN KNOB!
Never use tools. If the knob will not push in or turn by
hand, do not try to repair it. Call a qualified service technician. Forced or attempted repair may result in a fire or
explosion.
2.
Light the pilot and continue to depress the knob for approximately thirty seconds. Release the knob and affirm that
the pilot flame is still present.
If the pilot flame extinguishes, repeat steps 1 and 2 again, this time depress knob for
one minute. If pilot flame still extinguishes upon releasing the knob, assure than the thermocouple connection is tight.
Repeat steps 1and 2 again. If the pilot flame still extinguishes upon releasing the knob, call your service
technician/dealer
.
3.
Upon lighting the pilot, continue to turn the knob counterclockwise toward the “FULL ON” position.
IMPORTANT: GAS WILL NOT FLOW TO THE EMBER BURNER UNTIL THE SERVOTAP (CSC-BLOCK) IS
ENGAGED USING ON OF THE REMOTE CONTROL.
REMOTE OPERATION OF SERVOTAP SYSTEM
1.
The flame height from the main burner can be turned up and down and on or off using the Remote Control (See
“Remote Control Installation Instructions” for proper operation if the remote control). If using the Remote Control it is
recommended that the remote receiver be located outside the fireplace. The servotap system uses a solenoid valve
to turn the gas flow up and down and on or off. When the main burner is “ON” and flame is present the “OFF” button
on the remote control will turn the main burner completely “OFF”.
USE THE “OFF” BUTTON ON THE REMOTE TO
PROPERLY TURN THE MAIN BURNER FULLY OFF.
SHUT-OFF PROCEDURE
1.
Turn Knob (
Figure 2
) clockwise until reaching stop. Press down slightly and continue turning clockwise from “PILOT”
position to the “OFF” position.
*Very high-pressure gas surges may result in internal damage or leaks. If you suspect your control has been exposed
to more than 1 1/2 times its maximum, have the unit checked by an expert.
FOR YOUR SAFETY
WARNING: If you do not follow these instructions exactly, a fire or explosion may occur
resulting in property damage, personal injury, or loss of life.
Remote Control (RC-S6V-ST)