DO NOT USE A NATURAL GAS SET FOR PROPANE OR A PROPANE SET FOR NATURAL GAS.
WHEN USING PROPANE (LPG) GAS AN AUTOMATIC PILOT SYSTEM MUST BE INSTALLED.
This appliance is shipped with an air mixer containing a specific orifice size for the unit. The
appliance must use the air mixer. Manipulation or modification of the air mixer will void the
manufacturer’s warranty.
1. There are many different local codes for gas fire logs. The installation of this set must conform with
local codes or, in the absence of local codes, to the National Fuel Gas Code ANSI Z223.1 1999.
2.
This log set is designed for use with PROPANE Gas.
3. When glass fireplace doors are used, always operate gas log set with the doors fully open to allow for
proper combustion air.
4. A fire screen must be in place when the log set is in use.
5. The appliance and its individual shut off valve must be disconnected from the gas supply piping
system at test pressures in excess of ½ psig. The appliance must be isolated from the gas supply
piping system by closing its individual manual shut off valve during any pressure testing of gas supply
system at test pressures equal to or less than ½ psig.
6. Minimum inlet supply pressure for Natural Gas is 7” water column. Maximum inlet supply pressure for
Natural Gas is 10 ½” water column.
7. After burning, the logs become fragile and should not be handled. Knocking or rubbing logs can cause
concrete to crumble and is not covered under the warranty.
8. Use a soft, dry paintbrush for periodic dusting of the gas fire logs. Special care must be taken to clean
the birch logs. Rubbing will remove soot but will also remove the white pigments.
9.
Do not burn wood with this set.
INSTALLING YOUR
HARGROVE
GAS LOGS
Remove all the parts from the shipping container. Your set includes the following parts:
Number by Set
16”-21” Sets24” Sets 28”-30 Sets 36” Sets
1. Pedestal Grate
PG-16
PG-20
PG-25
PG-30
2. Ember Burner
EM-14
EM-18
EM-22
EM-26
3. Vermiculite
VM-1
VM-1
VM-1
(2) VM-1
4. Fire Embers
RW
RW
RW
(2) RW
5. Safety Pilot Control CPC
CPC
CPC
CPC
6. Aluminum Connector AC-18
AC-18
AC-18
AC-18
7. Fire Logs
*Number of logs are determined by the set size. Logs not illustrated.
8. Damper Stop (optional)
DS
DS
DS
DS
9. Volcanic Cinders
VC
VC
VC
VC
10. Black Cap CAP-8 CAP-8 CAP-8 CAP-8
11. Brass Elbow
50-6-8 50-6-8 50-6-8 50-6-8
12. AM/AM-N AM-48 AM-48 AM-42 AM-42
GENERAL INFORMATION
NOTE:
PERSONNEL QUALIFIED TO INSTALL GAS APPLIANCES MUST INSTALL GAS LOGS.
3
4
5
6
8
9
10
11
12
1
2
3
4
5
6
8
9
10
11
12
f i r e - p a r t s . c o m