DO NOT USE  A NATURAL GAS SET FOR PROPANE OR  A PROPANE SET FOR NATURAL GAS.   

WHEN USING PROPANE (LPG) GAS AN AUTOMATIC PILOT SYSTEM MUST BE INSTALLED.

 

This  appliance  is  shipped  with  an  air  mixer  containing  a  specific  orifice  size  for  the  unit.    The 

appliance  must  use  the  air  mixer.    Manipulation  or  modification  of  the  air  mixer  will  void  the 

manufacturer’s warranty. 

1.  There are many different local codes for gas fire logs.  The installation of this set must conform with 

local codes or, in the absence of local codes, to the National Fuel Gas Code ANSI Z223.1 1999. 

2. 

This log set is designed for use with PROPANE Gas.

 

3.  When glass fireplace doors are used, always operate gas log set with the doors fully open to allow for 

proper combustion air. 

4.  A fire screen must be in place when the log set is in use. 

5.  The  appliance  and  its  individual  shut  off  valve  must  be  disconnected  from  the  gas  supply  piping 

system at test pressures in excess of ½ psig.  The appliance must be isolated from the gas supply 

piping system by closing its individual manual shut off valve during any pressure testing of gas supply 

system at test pressures equal to or less than ½ psig. 

6.  Minimum inlet supply pressure for Natural Gas is 7” water column.  Maximum inlet supply pressure for 

Natural Gas is 10 ½” water column. 

7.  After burning, the logs become fragile and should not be handled.  Knocking or rubbing logs can cause 

concrete to crumble and is not covered under the warranty. 

8.  Use a soft, dry paintbrush for periodic dusting of the gas fire logs.  Special care must be taken to clean 

the birch logs.  Rubbing will remove soot but will also remove the white pigments. 

9. 

Do not burn wood with this set.

 

 

 

 

INSTALLING YOUR 

HARGROVE 

GAS LOGS 

Remove all the parts from the shipping container.  Your set includes the following parts: 

 

Number by Set 

 

16”-21”               Sets24” Sets           28”-30 Sets           36” Sets 

 

1.  Pedestal Grate 

 

     PG-16 

 

   PG-20 

 

     PG-25 

 

  PG-30 

 

2.  Ember Burner 

 

     EM-14 

 

   EM-18 

 

     EM-22 

 

  EM-26 

 

3.  Vermiculite   

                  VM-1 

 

   VM-1  

                   VM-1 

             (2) VM-1 

 

4.  Fire Embers  

                    RW 

                  RW   

 

       RW 

 

  (2) RW 

 

5.  Safety Pilot Control                     CPC 

 

    CPC  

                   CPC 

 

    CPC 

 

6.  Aluminum Connector                  AC-18 

 

   AC-18 

 

     AC-18 

 

   AC-18 

 

7.  Fire Logs 

 

 

*Number of logs are determined by the set size.  Logs not illustrated. 

 

8.  Damper Stop (optional) 

       DS  

                  DS    

                     DS 

 

     DS 

 

9.  Volcanic Cinders 

 

       VC  

                  VC   

 

        VC 

 

     VC

 

          

10. Black Cap                                CAP-8                          CAP-8                               CAP-8                          CAP-8 

         

 11. Brass Elbow  

 

    50-6-8                           50-6-8                               50-6-8                          50-6-8 

          

12. AM/AM-N                                   AM-48                           AM-48                               AM-42                          AM-42 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL INFORMATION 

NOTE:  

PERSONNEL QUALIFIED TO INSTALL GAS APPLIANCES MUST INSTALL GAS LOGS. 

  4 

  8 

  9 

10 

11 

12 

  8 

10 

11 

12 

f i r e - p a r t s . c o m

Summary of Contents for RGA 2-72

Page 1: ...sted up the chimney If fumes or soot from the gas burning are evident in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected ADEQUATE VENTILATION IS REQUIRED IT IS THE HOMEOWNERS RESPONSIBILITY TO ASSURE THEIR FIREPLACE HAS ADEQUATE DRAFT WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOL...

Page 2: ...than psig 6 Minimum inlet supply pressure for Natural Gas is 7 water column Maximum inlet supply pressure for Natural Gas is 10 water column 7 After burning the logs become fragile and should not be handled Knocking or rubbing logs can cause concrete to crumble and is not covered under the warranty 8 Use a soft dry paintbrush for periodic dusting of the gas fire logs Special care must be taken to ...

Page 3: ...erence points Remove the grate and proceed with the gas connection See Figure 2 GAS CONNECTION 1 The gas supply line should be inside diameter ID up to 30 feet and for longer distances 2 Tighten the black pipe cap on the end of the burner pan pipe 3 Use the aluminum connector to connect the gas supply to the ember burner When bending the aluminum tubing use proper bending procedures to avoid kinki...

Page 4: ...d down If the logs are laid flat on the grate the safety pilot control parts will overheat and shut the system off 2 The second longest log is the back log It is positioned on the back pedestal of the grate with the flat side down 3 The remaining logs are top logs These logs are placed diagonally across the bottom logs and can be arranged to create the most realistic flame patterns See Figure 4 VO...

Page 5: ...plicable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WAR...

Reviews: