Hargrove OBLO19N1T Installation And Operation Manual Download Page 8

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

LOG INSTALLATION 

  8 
 
 

 

1.  Identify the logs using the pictures on this page.  
2.  Take the 1110 and 0602 and put them into the basket resting on the front of the basket 

as is shown above. (Fig 1.) 

3. Place the 104 with the forks down and leaning on the 1110 as is shown above.  
    (Fig 2.) 
4. Take the 112 and 2512 and place them with the 2512 resting on the 602 and the 
    112 resting on the 1110 as shown below (Fig 4.) 

Fig 1 

Fig 2 

Fig 3 

Summary of Contents for OBLO19N1T

Page 1: ...nstaller service agency or the gas supplier NOTE This appliance is only for use with the type of gas indicated on the rating plate Solid fuels shall not be burned in a fireplace where a decorative app...

Page 2: ...o assure their fireplace has adequate draft If fumes or soot from the gas burning are evident in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operat...

Page 3: ...ht 19 22 10 16 Factory Built Appliance Input Rate kBTU hr 20 30 34 40 Chimney Height ft Minimum Opening sq in Minimum Diameter in 10 11 3 16 6 18 8 5 22 1 15 8 6 12 6 14 5 5 17 3 20 7 5 10 8 12 3 4 14...

Page 4: ...LINE Ensure gas line is in safe condition and that it is adequate for the installation Check gas line sizing to ensure it is properly sized for the appliance For ease of installation gas line should...

Page 5: ...8 Male X 5 16 Compression F 68 0506 3 8 Female X 5 16 Compression G SE 6 3 8 Black Elbow H N 6 2 5 3 8 X 1 Pipe Nipple I REG 4 Regulator NG REG 10 Regulator LP J 48 6 3 8 Brass Union K AM 3 8 X 3 8 33...

Page 6: ...m inlet supply pressure for the purpose of input adjustment is 5 0 inches natural gas 11 inches propane gas in water column The maximum inlet supply pressure is 10 5 inches natural gas 13 inches propa...

Page 7: ...within 4 seconds Carefully check the connections for leaks using a soapy solution NOTE if the pilot will not stay lit after several tries turn the control off and call a technician IMPORTANT These co...

Page 8: ...hem into the basket resting on the front of the basket as is shown above Fig 1 3 Place the 104 with the forks down and leaning on the 1110 as is shown above Fig 2 4 Take the 112 and 2512 and place the...

Page 9: ...black volcanic cinders are used to cover the fireplace floor fittings and tubing around the burner system Although not functional the back cinders act as a picture frame to show off the glowing ember...

Page 10: ...has been underwater LIGHTING INSTRUCTIONS GAS OUTLET GAS INLET Pilot Adjustment Screw Pilot Gas Supply 4 Find pilot follow metal tube from the gas control behind the burner pan Pilot Burner Thermocou...

Page 11: ...y Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQ...