Hargrove GAS LOGS Installation And Operation Manual Download Page 2

DO NOT USE A NATURAL GAS SET FOR PROPANE OR A PROPANE SET FOR

NATURAL GAS.  WHEN USING PROPANE (LPG) GAS AN AUTOMATIC PILOT SYSTEM 

MUST BE INSTALLED.

1. There are many different local codes for gas fire logs. The installation of this set must conform 

with local codes or, in the absence of local codes, to the National Fuel Gas Code ANSI Z223.1 

1999.

2.

This log set is designed for use with Natural Gas.

3. When glass fireplace doors are used, always operate gas log set with the doors fully open to 

allow for proper combustion air.

4. A fire screen must be in place when the log set is in use.

5. The appliance and its individual shut off valve must be disconnected from the gas supply

piping system at test pressures in excess of 1/2 psig. The appliance must be isolated from the

gas supply piping system by closing its individual manual shut off valve during any pressure

testing of gas supply system at test pressures equal to or less than 1/2 psig.

6. Minimum inlet supply pressure for Natural Gas is 7" water column.  Maximum inlet supply

pressure for Natural Gas is 10 1/2" water column.

7. After burning, the logs become fragile and should not be handled. Knocking or rubbing logs

can cause concrete to crumble and is not covered under the warranty.

8. Use a soft, dry paintbrush for periodic dusting of the gas fire logs.  Special care must be taken 

to clean the Birch logs.  Rubbing will remove soot but will also remove the white pigments.

9.

Do not burn wood with this set

INSTALLING YOUR 

HARGROVE

GAS LOGS

Remove all the parts from the shipping container. Your set includes the following parts...

GENERAL INFORMATION

NOTE

:

GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED TO INSTALL GAS APPLIANCES.

Number by Set

16”-21” Sets

24” Sets

28”-30” Sets

36” Sets

1. Pedestal Gate

P G – 1 6

P G – 2 0

P G – 2 5

P G – 3 0

2. Ember Burner

E B -1 4

E B – 1 8

E B – 2 2

E B – 2 6

3. Silica Sand

( 1 ) S D - 8

( 1 )  S D – 1 0

( 1 ) S D - 1 2

( 2 ) S D – 8

4. Fire Embers

E M

E M

E M

( 2 ) E M

5. Safety Pilot Control (optional)

S P C / C P C

S P C / C P C

S P C / C P C

S P C / C P C

6. Aluminum Connector

A C – 1 8

A C – 1 8

A C – 1 8

A C – 1 8

7. Fire Logs

* Number of logs determined by set size

8. Damper Stop (optional)

D S

D S

D S

D S

9. Volcanic Cinders

V C

V C

V C

( 2 ) V C

Summary of Contents for GAS LOGS

Page 1: ...xide and soot Under normal conditions these products are exhausted up the chimney If fumes or soot from the gas burning are evidenced in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected ADEQUATE VENTILATION IS REQUIRED IT IS THE HOMEOWNERS RESPONSIBILITY TO ASSURE THEIR FIREPLACE HAS ADE...

Page 2: ... Gas is 7 water column Maximum inlet supply pressure for Natural Gas is 10 1 2 water column 7 After burning the logs become fragile and should not be handled Knocking or rubbing logs can cause concrete to crumble and is not covered under the warranty 8 Use a soft dry paintbrush for periodic dusting of the gas fire logs Special care must be taken to clean the Birch logs Rubbing will remove soot but...

Page 3: ...lly open during operation Place a lighted match next to the burner pipe Do not hold the match in your hand while lighting the gas Turn the gas supply on slowly until the gas ignites Check the flame for even distribution flame height and pressure After checking the flame turn off the fire To turn off the fire turn the gas valve off Do not close the damper until all the flames have died Keep the gla...

Page 4: ...rts will over heat and shut the system off 2 The second longest log is the back log It is positioned on the back pedestal of the grate with the flat side down 3 The remaining logs are top logs These logs are placed diagonally across the bottom logs and can be arranged to create the most realistic flame patterns See Figure 4 Figure 4 GRATE PLACEMENT Place the grate over the ember burner using the r...

Page 5: ...n experienced service technician trained in gas safety equipment 2 Turn off gas supply before installing valve 3 All piping must meet applicable local codes and ordinances and the national fuel gas code ANSI Z223 1 NFPA NO 54 4 All wiring must meet applicable electrical codes and ordinances 5 Check out the complete system after installing the valve 6 Prior to installation verify conformance with b...

Page 6: ...s void if the CPC C is installed behind the burner pan in the fireplace Fig 1 Parts List Fig 2 1 CPC C Concentric Safety Gas Valve 2 HS CPC 250 Concentric Heat Shield w Fiberglass Mat 3 RSTPB 18 Thermocouple Pilot Burner Assembly 4 SC 3 Stainless Steel Extension Connector 5 48 6 Brass Union 6 50 6 6 3 8 FIP X 3 8 FL 7 N 6X1 5 3 8 X 1 1 2 Black Nipple DO NOT INSTALL CPC C BEHIND THE EMBER BURNER PA...

Page 7: ...y 5 If a vise or open ended wrench is used to hold the control while installing piping do not tighten excessively as this may damage the control INSTALLATION INSTRUCTIONS CPC INSTALLATION See Fig 3 1 Attach the Brass 50 6 8 in accessory kit parts packet to the pipe extending out of the Ember Burner pan Make sure the flared end of the 50 6 8 is facing toward the front of the Ember Burner Pan 2 Conn...

Page 8: ...on position full counterclockwise position to supply full flow of gas to main burner 6 You can adjust the flame height by the control knob if you turn it back towards the pilot position you will decrease the gas flow in turn you will decrease the flame height FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in you...

Page 9: ... tubing or replace the tubing 2a Tighten fitting that connects thermocouple line to the pilot control valve 2b Adjust the flame on the pilot burner in accordance with the pilot control instructions or replace the pilot orifice with a larger orifice 2c Adjust the flame on the pilot burner in accordance with the pilot control instructions or replace the pilot orifice with a larger one 2d A cold junc...

Page 10: ... with a smaller opening NOTE This will reduce the amount of flame on logs 6a Clear passageway through sand to allow easier and quicker access for gas from ember burner to pilot light 6b Assure pilot light directs flame over ember burner pan as well as properly hitting the thermocouple 7a Assure thermocouple and pilot burner assembly are mounted on the back side of the ember burner pan per safety p...

Page 11: ...anty applicable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRIT...