background image

3

FIREPLACE SIZES

Each gas log set requires a minimum clearance for the front opening, height, and minimum depth.  To determine the 
largest set that will fit into a fireplace, the depth and width are the critical dimensions.  The following illustration reflects a 
view directly above the fireplace looking down.  The minimum height for this model is 22 inches.

        TABLE I

         (Table I indicates the minimum depth and width for each set size)

MODEL

21” RADIANT GLOW
24” RADIANT GLOW
30” RADIANT GLOW

MINIMUM DEPTH

16 INCHES
18 INCHES
18 INCHES

MINIMUM FRONT WIDTH

24 ½ INCHES
28 ½ INCHES

34 INCHES

FRONT

WIDTH

DEPTH

TABLE II

FOR MASONRY BUILT FIREPLACES

FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING

COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR

INSTALLATION IN SOLID FUEL BURNING FIREPLACES

     Appliance Input Rate (kBTU/hr)

     20                30

      40               50               60               70               80             90                100               110                120

6

8

10

15

20

30

Chimney

Height*(ft)

    17.6             25.7             33.8            41.7            49.2            56.6            64.0           71.4             78.8              86.2              93.5

    16.5             23.7             31.2            38.7            45.5            52.4            59.7           66.9             74.1              81.3              88.6

    15.1             21.7             28.7            35.2            41.7            48.2            54.3           60.2             66.1              72.0              77.9

    14.1             19.9             26.1            32.0            37.7            43.2            48.8           54.1             59.4              64.6              69.9

    12.9             18.5             23.7            28.8            34.3            39.8            44.4           49.1            53.8              58.4              63.0

    12.2             16.9             21.6            26.5            31.2            35.9            40.3           44.5             48.6              52.7              56.6

Minimum Opening** (sq. in.)

*  Height is from hearth to top of chimney and the minimum height is 6 feet.
**  Chart shows minimum opening (sq. in.) for a given height and input rate.

f i r e - p a r t s . c o m

Summary of Contents for AKRG5/8CPCLP

Page 1: ...r other flammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS 1 Do not try to light any appliance 2 Do not touch any electrical switch...

Page 2: ...s burning and the damper is fully opened it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected Consult your fireplace specialist 7 A...

Page 3: ...TABLE II FOR MASONRY BUILT FIREPLACES FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES Appliance Input R...

Page 4: ...8 Brass Elbow 21 SETS PG 16 EB 14 HBF 18 CPC C HS CPC 250 PGRG2124 RSTPB 18LP EM 1 RGAC 12 VM 1 VC 1 NOT SHOWN DS AC 18 PPH 2 60 AM 55 58 6 6 SE 6 CAP 8 REG 10 0 LP EXT NOT SHOWN N 6 x 2 5 49 6 6 24 S...

Page 5: ...s connection See Figure II GAS CONNECTIONS 1 The gas supply line should be 1 2 inch inside diameter up to 30 feet and 3 4 inch for longer distances 2 Use the aluminum connector to connect the gas supp...

Page 6: ...w it to fasten into place on the grate The bottom side with the slots is a flat untextured side that has notches that lay over the pedestals of the grate Place the slots over the vertical portion of t...

Page 7: ...icable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations...