WARNING:  This appliance assembly contains burner assembly orifices specifically for the 
input gas and Btu rating.  Modifying or failure to use the factory orifice may cause property 
damage, personal injury or loss of life.

1. This appliance has been assembled for a specified inlet supply gas.  Do not use a natural appliance with a propane gas 

inlet supply.  Do not use a propane appliance with a natural gas inlet supply.

2. There are many different local codes for gas log appliances.  The installation and the provisions for combustion and 

ventilation air must conform with local codes and/or in the absence of local codes, with the National Fuel Gas Code ANSI
Z223.1 (current revision)

3. A qualified personnel, service agent, or the gas supplier must install this appliance.

4. This appliance must be installed only in a solid fuel-burning fireplace with a working flue and constructed of

noncombustible material.  Solid fuels cannot be used in a fireplace where a Hargrove gas unit has been installed.

5. A permanent free opening must be provided by either the fireplace chimney or chimney damper to vent flue gas.  Any 

chimney damper must be fixed in such a manner, which will maintain the permanent free opening at all times.  Use Table 
II to determine the minimum permanent free opening based upon chimney height and the appliance BTU rate.  Refer to 
the Damper Stop instructions for additional directions.

6. Two factors, chimney height and the BTU rating determine the minimum free opening.  Many other factors will affect the 

fireplace drafting.  It is the homeowner’s responsibility to assure their fireplace has an adequate draft.  If fumes or soot 
exist in the room while the gas is burning and the damper is fully opened, it indicates that the fireplace draft is defective.
Do not operate your gas log set until the fireplace draft is corrected.  Consult your fireplace specialist.

7. A fireplace screen must be in place when the appliance is operating unless other provisions for an air supply are 

provided.  The screen shall have openings for the introduction of fresh air for the unit.

8. When glass fireplace doors are used, always operate the gas log appliance with the doors fully open to allow fresh air for 

the appliance and to keep the controls from overheating.

9. The minimum inlet supply pressure for the purpose of input adjustment is 5.0 inches W.C. (natural gas) and 8.0 inches

W.C. (propane gas).  The maximum inlet supply pressure is 10.0 inches W.C. (natural gas) and 12.0 inches W.C.
(propane gas).

10. The appliance and it’s individual shut off valve must be disconnected from the gas supply piping system during any 

pressure testing in excess of ½ psig (3.5 kPa).  The appliance must be isolated for the gas supply piping system by 
closing its individual manual shut off valve during pressure tests in excess of ½ psig (3.5 kPa).

11. The fireplace chimney or venting system should be examined annually and cleaned as required by a qualified agency.

12. After burning for several hours the logs become fragile and should not be handled.  Knocking or rubbing logs can cause 

the log to crumble and is not covered under the warranty.

13. Use a soft, dry paintbrush to clean the logs.  A periodic dusting may be required to remove carbon deposits.  A rubbing 

action will remove the soot but will also remove some of the color pigments of the log.

14. To clean the burner, shut off the gas supply, remove burner pan media, and vacuum gas ports.  After cleaning replace 

burner pan media and light the pilot according to the lighting instructions.

IMPORTANT INFORMATION

f i r e - p a r t s . c o m

Summary of Contents for AKRG5/8CPCLP

Page 1: ...r other flammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS 1 Do not try to light any appliance 2 Do not touch any electrical switch...

Page 2: ...s burning and the damper is fully opened it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected Consult your fireplace specialist 7 A...

Page 3: ...TABLE II FOR MASONRY BUILT FIREPLACES FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES Appliance Input R...

Page 4: ...8 Brass Elbow 21 SETS PG 16 EB 14 HBF 18 CPC C HS CPC 250 PGRG2124 RSTPB 18LP EM 1 RGAC 12 VM 1 VC 1 NOT SHOWN DS AC 18 PPH 2 60 AM 55 58 6 6 SE 6 CAP 8 REG 10 0 LP EXT NOT SHOWN N 6 x 2 5 49 6 6 24 S...

Page 5: ...s connection See Figure II GAS CONNECTIONS 1 The gas supply line should be 1 2 inch inside diameter up to 30 feet and 3 4 inch for longer distances 2 Use the aluminum connector to connect the gas supp...

Page 6: ...w it to fasten into place on the grate The bottom side with the slots is a flat untextured side that has notches that lay over the pedestals of the grate Place the slots over the vertical portion of t...

Page 7: ...icable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations...

Reviews: