HARDY MANUFACTURING CO., INC (MODEL C3 & C5) PAGE 38
1. Close all doors and
make sure they are
securely fastened.
2. If the seal is bad it will
need replacing. Call
your local Hardy
Dealer for parts. See
Owners Manual for
replacing door seals.
3. Unplug blower motor.
Check lid and blower
for creosote buildup.
Remove blower,
dissemble, clean, and
oil.
4. Check temperature
setting on aquastat.
Should be 170ºF. If
aquastat is allowing
blower to run until
water boils, replace
aquastat.
5. Repair or replace all
lines or connections
that are leaking.
1. Doors open
2. Defective door
seals
3. Damper blower
lid stuck open
4. Damper
aquastat
defective
5. Water lines /
connections
leaking
Excessive fuel
usage
Or
Overheating
(boiling)
Heater water boils
(Symptom –Popoff
valve is relieving)
1. See area of trouble:
“Pump Operation”
2. Open or replace
valves
3. Bleed lines if air is
trapped non pressured
lines require pump to
be running.
4. Disconnect the inlet
and outlet of the hot
water coil and clean
with a scale remover
solution.
5. Bleed air from hot
water coil
Water not
circulating through
the heat loop
1. Pump not
operating
2. Inline valves
closed/bad
3. Air trapped in
plumbing
4. Scale deposits in
hot water coil
reducing water
flow and
restricting heat
transfer.
5. Air lock in hot
water coil.
NO HEAT
Blowing cold
air in house
Water
temperature is
“HOT”
Power “OK”
8-1
General Trouble Shooting Guide (continued)
Corrective Action
Possible Causes
Complaint
Area of Trouble