HARDY MANUFACTURING CO., INC (MODEL C3 & C5) PAGE 33
Section VIII
APPENDIX
8-1
General Trouble Shooting Guide
WARNING
HAZARDOUS VOLTAGE WILL CAUSE DEATH, SEVERE PERSONAL INJURY OR
SUBSTANTIAL PROPERTY DAMAGE. ALWAYS FOLLOW THE SAFETY
PRECAUTION WARNINGS POSTED IN THIS INSTRUCTION BOOKLET.
Complaint
Ground
Fault
Interrupter
Receptacle
Tripping
Possible Cause
Corrective Action
1. Moisture in receptacle
2. Receptacle not
grounded properly.
1. Remove cover and
check for moisture
inside box. If moisture
is present, use blow
dryer to dissipate. If
moisture inside box
continues to be a
problem, wrap the box
with cellophane to
protect from moisture.
2. Remove cover and
check the bare copper
wire connected to the
green screw for secure
attachment. Test
Receptacle for proper
operation.
Moisture or corrosion in
electrical connections or
windings
Check electrical
connections and windings
for moisture or corrosion.
Clean or dry and then test
for proper operation.
Pump Motor
Corrosion in motor
electrical connections or
windings
Check electrical
connections, capacitor and
motor winding for bad
connections or corrosion.
Clean, dry and then test
for proper operation.
Liquid Level
Switch, Low
water light.
Bad connections possibly
to ground.
Check electrical
connections for bad
connections or corrosion.
Clean, dry and then retest
for proper operation.
Area of Trouble
Ground Fault
Interrupter
Receptacle
Forced air draft
blower and
damper
solenoid.