TRANSMITTED
CORRECT?
RECEIVED
REASON
-123.45
Y
-123.45
5 NU MINUS SIGN + DECIMAL POINT( (**) above)
1234.56
Y
1234.56
6 NU DECIMAL POINT ((*) above)
-12345
Y
-12345
5 NU MINUS SIGN ((**) above)
-123456
N
-12345
The “6” WOULD BE TRUNCATED SINCE ONLY 5 NUMER-
ICS + THE MINUS SIGN IS LEGAL ((**) above)
1234x.67
N
1234x.6
The “7” WOULD BE TRUNCATED SINCE ONLY A MAXIMUM
OF 6 NU DECIMAL POINT IS LEGAL ((*) above)
Chapter 7 - Serial Communications
7-7
3)
When return data is not valid for the command, an "A" is
returned by the instrument. For example:
START
CHAR
INSTRUMENT
ADDRESS
CMD
SUB-CMD
6 BYTE DATA
D6 ... D1
MODE
CR
2 BYTE CHECKSUM
EOT
CHK-1
CHK-2
>
10
A
CRLF
CHK-1
CHK-2
EOT
Command Sets
X (Xmit) Command
•
Xmit is issued with a sub command. Only one sub command per
command is allowed.
•
Transmit data specified in SUB-CMD as follows:
SUB-CMD
MEANING
REL
Relay (This command transmits relay
status)
RECEIVED
DATA
RELAY
NUMBER
RELAY
FUNCTION
01
5
REC
02
4
ON/OFF
04
3
SHUTOFF
08
1
REFILL
10
2
ALARM
20
8
(RESERVED)
40
7
(RESERVED)
80
6
BATCH COMPLETE
Summary of Contents for HI 2160RC PLUS
Page 1: ...HI 2160RCPLUS Rate Controller Operation and Installation Manual ...
Page 23: ...HI 2160RCPLUS MANUAL 2 6 ...
Page 49: ...HI 2160RCPLUS MANUAL 3 26 ...
Page 67: ...HI 2160RCPLUS MANUAL 4 18 ...
Page 91: ...HI 2160RCPLUS MANUAL 5 24 ...
Page 151: ...HI 2160RCPLUS MANUAL 7 12 ...
Page 187: ...HI 2160RCPLUS MANUAL 8 36 ...
Page 207: ...HI 2160RCPLUS MANUAL 9 20 ...
Page 219: ...Data Worksheets WKSHT 6 ...