HI 1769-WS/HI 1769-2WS WEIGH SCALE MODULE
4-16
input table is called the command STATUS. Nor-
mally, a 0 value of STATUS means that the command
completed OK and a non-zero status indicates some
kind of error.
Command
Operation
Step 1.
To start a command, place the command
number into the first word of the output
table.
Step 2.
The Input Table contains the response for
that command.
Step 3.
If a selected command needs other data
with it, the other words in the output table
should be filled in first, then the command
number. Example:
•
WRITEPARAM0, should have
PARAMETER0 Data placed into the
output table before the command
number is written, otherwise the com-
mand will fail.
Possible
COMMAND
STATUS Values
•
#define SUCCESS 0
•
#define ERRORADCONVERT 0x0001
•
#define ERRORADFAILURE 0x0002
•
#define STATUSINMOTION 0x0040
•
#define OUTOFTOLERANCE -3
•
#define INDEXOUTOFRANGE -4
•
#define NOSUCHCMD -5
•
#define C2FAILNODEVS -6
•
#define C2FAILCAPEQ -7 // failure, capacities
not equal
•
#define HARDCALFAILCOUNST -8 // failure,
not enough ADC counts between high, low
Summary of Contents for HI 1769-2WS
Page 14: ...HI 1769 WS HI 1769 2WS WEIGH SCALE MODULE 1 6 ...
Page 27: ...Chapter 3 Installation 3 9 FIG 3 7 RAIL FASTENERS IN THE CLOSED POSITION ...
Page 60: ...HI 1769 WS HI 1769 2WS WEIGH SCALE MODULE 4 26 ...
Page 74: ...HI 1769 WS HI 1769 2WS MANUAL 6 8 ...
Page 82: ...HI 1769 WS HI 1769 2WS MANUAL Weighing System Tests 1 4 wrist strap grounding device 3 2 ...