Page 1 of 4
Overlay Troubleshooting Procedure
Inferno 3500 & GC Rotisseries
S
-1014
-0
2
.d
o
c
Time Required:
60-90 minutes
Tools Required
Multimeter
Wire (for bridging pins on display circuit board)
Ensure the rotisserie is switched off, unplugged and cool to the touch before
performing this procedure.
Always verify the function of the control panel via the display screen, do not use sounds to
verify their functionality.
Your equipment may not appear exactly as shown in the illustrations in this document,
however the locations of components and the procedure will remain the same.
The best method for testing the functionality of all the buttons on the control panel can be
found in Section 1.4 at the end of this document.
1.1.1 If your unit has a reset button:
1. Check and see if your rotisserie is equipped with a
reset button, it is located on the right side of the
unit right next to the control panel as shown in
Figure 1.
2. If your unit does have a reset button, ensure the
power cord is unplugged then press and hold the
button for 30 seconds to reset the control board.
3. Plug the rotisserie back in and test the unit, if you
are still experiencing problems with the control
panel, proceed to section 1.2 on page 2.
1.1.2 If your unit does not have a reset button:
1. Unplug the rotisserie from the mains electrical
supply. Remove the side panel as shown in
Figure 2. Locate the control circuit board.
1.1
Reset the Control Board’s Battery
Figure 1: Push and hold reset button.
Figure 2: Remove Side Panel.
Control Board
Reset Button