Overlay Troubleshooting Procedure 

Inferno 3500 & GC Rotisseries 

S

-1014

-0

2

.d

o

c

 

 

1.  Ensure  the  rotisserie  is  plugged  in,  turned  on  and  that 

the ribbon cable is disconnected from the display circuit 
board. 

 

2.  To simulate the activation  of a button,  you must bridge 

(or short circuit) the two corresponding pins (see Figure 
for details). It is important that you short circuit ONLY 
the two pins for the button, accidentally bridging 3 pins 
will  give  erroneous  results  but  will  not  damage  the 
circuit  board.    The  numbers  for  each  button  can  be 
found in Figure 7 on page 3. 

 
 
 

3.  The buttons on the control panel only work in the proper context (for example: the +5 min button will not do anything 

when the rotisserie is in cleaning mode).  The following describes methods of accessing the proper modes for 
testing each button.  If only a single button has been reported as faulty, you may start with the section specific to 
that button, otherwise it is recommended that you follow each section in sequence.  You must always start each 
section in idle mode (Indicated by the display showing “PREHEAT OR CLEAN”). 

a.  To initially reach idle mode on an Inferno GC, simply turn on the rotisserie. 
b. 

To initially reach idle mode on an Inferno 3500, turn on the rotisserie, wait for the display to show “PLEASE 
DO NOT ADD WATER..” then press 

ENTER

1.4.1  To Test EDIT, 1-2, 3-4, 5-6, 7-8, and STOP 

-

Start from idle mode (“PREHEAT OR CLEAN” on the display)

 

Hold 

EDIT

 (pins 3 & 8) and 

1-2

 

(Pins 1 & 5) at the same time for 3 seconds.  The display should show “P0 / #-# SKS 

MANUAL”.  Do not change any settings, simply press 

STOP

 (pins 4 & 6) to go back to idle mode. 

The same message should be shown when repeating this step for the other favorite buttons (

EDIT

 (pins 3 & 8) and 

3-4

 (Pins 1 & 6)), (

EDIT

 (pins 3 & 8) and 

5-6

 (pins 1 & 7)), and (

EDIT

 (pins 3 & 8) and 

7-8

 (pins 1 & 8). 

1.4.2  To test PREHEAT and STOP 

-

Start from idle mode (“PREHEAT OR CLEAN” on the display) 

Press 

PREHEAT

 

(pins 2 & 5) (for Inferno GC units, the lever must be in the “COOK” position)  – the rotisserie will 

enter preheat mode and the display should show “PREHEATING PLEASE…”.  Press and hold 

STOP

 for 3 seconds 

to go back to idle mode. 

1.4.3  To test EDIT, +5 MIN, UP, DOWN, ENTER, and STOP 

-

Start from idle mode (“PREHEAT OR CLEAN” on the display)

 

Hold 

EDIT

  (pins  3  &  8)  and 

+5  MIN

  (pins  2  &  7)  for  3  seconds.    This  will  bring  you  to  the  2

nd

  level  programming 

menu.  The display should show “PROGRAMMING SECOND LEVEL”.  Press 

UP

 (pins 3 & 5), the display  should 

show  “CIRCULATION  PUMP…”.    Press 

ENTER

  (pins  2  &  6)

,  the  display  should  show  “PUMP  LOW  LIMIT…”.  

Press 

STOP

 

(pins 4 & 6), the display should show “CIRCULATION PUMP…”.  Press 

DOWN

 (pins 4 & 5) the display 

should show “PROGRAMMING SECOND LEVEL”.  Press 

STOP

 to return to idle mode. 

1.4.4  To test VIEW TEMP 

-

Start from idle mode (“PREHEAT OR CLEAN” on the display) 

Press 

VIEW TEMP

 (pins 2 & 8), the display should show the temperature and return to idle mode after 5 seconds. 

1.4.5  To test CLEAN and STOP 

-

Start from idle mode (“PREHEAT OR CLEAN” on the display) 

Press 

CLEAN

 

(pins 4 & 8) (for Inferno GC units, the lever must be in the “COOK” position)  –

 

The  display  should 

s

how “ENTER TO RUN OR STOP”.  Press and hold 

STOP

 (pins 4 & 6) for 3 seconds to return to idle mode. 

1.4  Test the Display Circuit Board 

 