background image

 

Page 2 of 4

 

Overlay Troubleshooting Procedure 

Inferno 3500 & GC Rotisseries 

S

-1014

-0

2

.d

o

c

 

 

2.  Unplug  the  battery  cable  from  the  circuit  board  as 

shown  in  Figure  3.  Leave  the  cable  unplugged  for 
at least 30 seconds then plug it back in.  

 

3.  Plug  the  rotisserie  back  in  and  test  the  unit,  if  you 

are  still  experiencing  problems  with  the  control 
panel, proceed to section 1.2 on this page. 

 
 
 
 

 

 
 

1.  Ensure  the  rotisserie  is  unplugged.    Locate  the 

display  circuit  board  inside  the  side  compartment 
immediately  behind  the  led  display  on  the  front  of 
the rotisserie. (See Figure 4) 

 

2.  Unplug the ribbon connector from the display board 

and  unplug  the  communications  cable  from  the 
display  board  and  controller  board.  (see  Figure  5 
and Figure 6)
 

 

3.  Do  a  pull  test  on  the  communication  cable  by 

gently pulling on each of the 3 wires in the cable at 
each  of  the  connectors.    After  pulling  the  wires, 
check the continuity of each wire on the cable with 
a multimeter.  This test ensures the wires are firmly 
attached to the connectors.   

 

4.  Reconnect  the  cable  and  ribbon  connector.    Doing  this  helps  remove  corrosion  from  the  connectors  and 

ensures that the connections are secure.  (see Figure 5 and Figure 6) 

 
Caution must be taken not to damage the ribbon cable as it is extremely fragile. 
 

 
 

5.  Plug the rotisserie back in and test the unit. If you 

are  still  experiencing  problems  with  the  control 
panel, proceed to section 1.4 on page 4. 

 

Figure 3: Unplug battery cable for 30 seconds. 

1.2  Check cable and ribbon connections on the display board 

 

Figure 4: Locate display controller board. 

 

Figure 5: Disconnect cables from display board. 

 

Figure 6: Unplug comm. Cable from control board. 

Battery Cable 

Display Board 

Communication 
Cable 

Communication 
Cable 

Ribbon Cable 