background image

7

www.hardlifeutility.com

BASE PLATE INSTALLATION

Refer to

 Figures 3 and 4

 to place the base plates for the C2620 and C2640 container shelters, respectively. All 

measurements are from centre to centre of the tubes.

1.  Arrange the 4 / 7 base plates (with tie-down ratchet on the left) (component code L1) and the 4 / 7 base 

plates (with tie-down ratchet on the right) (component code R1), as shown in 

Figures 3 and 4

, for C2620 

and C2640, respectively.

2.  For the C2640 container shelter, secure the L1 and R1 base plates to the container using steel plates for 

the base plates (component code 15A) and M12 x 30 mm screws (component code 15B), as shown in 

Figure 4.

3.  All the base plates should be welded on to the containers.

Figure 3 (C2620)

Summary of Contents for C2620

Page 1: ...INSTRUCTION MANUAL C2620 C2640 CONTAINER SHELTERS www hardlifeutility com ...

Page 2: ......

Page 3: ...03 SHELTER SPECIFICATIONS 03 COMPONENT LIST 04 ASSEMBLY AND INSTALLATION 05 TOOLS REQUIRED FOR INSTALLATION 05 SITE PREPARATION 05 CONTAINER SHELTER PLACEMENT 06 BASE PLATE INSTALLATION 07 FRAME ASSEMBLY 09 FRAME INSTALLATION 11 ROOF COVER INSTALLATION 13 MAINTENANCE 17 TABLE OF CONTENTS ...

Page 4: ...anual carefully prior to the assembly installa tion use and removal of the container shelters Improper site preparation assembly and maintenance of the container shelters may invalidate warranty Please reach out to your local dealer for any queries To ensure user friendly assembly of the container shelters each individual component is identified with their respective component code as indicated in...

Page 5: ...dication to determine if your judgment or reflexes may be impacted 7 Do not assemble the shelter in windy conditions fasten the base of the shelter in concrete if it s likely to be windy 8 Ensure personal safety during assembly of the shelter Wear safety goggles and gloves during assembly and exercise caution when handling clips and tubes 9 Ensure there is adequate ventilation for exhaust and othe...

Page 6: ...Tube 8 14 3 Bottom Bent Tube 8 14 4 Connection Purlin 15 30 5 Supporting tube 12 12 6 Clip 24 21 7 Lower Tensioning Tube for the Roof Cover 2 Groups 2 Groups 8 Roof Cover 1 1 9 M8 x 70 mm Bolts 48 94 10 M10 x 80 mm Bolts 20 35 11 Ropes 1 Dozen 1 Dozen 12 Ø32 Plastic Plug for the Lower Tensioning Tube 4 12 13 Ratchet Tie Down Straps 8 14 14 Angle Set 4 15 Tie Down Ratchet 8 14 15A Steel Plate for B...

Page 7: ...r 4 Sledge hammer 5 Wrench 6 Knife 7 Welding Machine 8 Scissors SITE PREPARATION To prepare the site for installing the shelter 1 Select a flat hard and level surface 2 Ensure that all the components are present by checking with the Component List prior to installation 3 Mark out a site using a string or chalk It is recommended that the string or chalk line is slightly larger than the shelter area...

Page 8: ...6 www hardlifeutility com Figure 2 C2640 CONTAINER SHELTER PLACEMENT Place the two containers in the correct position as shown in Figures 1 and 2 Figure 1 C2620 ...

Page 9: ... ratchet on the left component code L1 and the 4 7 base plates with tie down ratchet on the right component code R1 as shown in Figures 3 and 4 for C2620 and C2640 respectively 2 For the C2640 container shelter secure the L1 and R1 base plates to the container using steel plates for the base plates component code 15A and M12 x 30 mm screws component code 15B as shown in Figure 4 3 All the base pla...

Page 10: ...8 www hardlifeutility com Figure 4 C2640 ...

Page 11: ... www hardlifeutility com FRAME ASSEMBLY The frame for the C2620 and C2640 container shelters are made of four and seven group arches respectively as shown in Figures 5 and 6 Figure 5 C2620 Figure 6 C2640 ...

Page 12: ...e 2 Two bottom bent tubes component code 3 M8 X 70 mm bolts component code 9 The tubes are assembled to form an arch using M8 X 70 mm bolts as shown in Figures 5 6 7 and 8 The other group arches are also assembled in the same manner NOTE Ensure that the screw head is in the right direction to prevent it from tearing the roof cover Assemble all the arches and lay them on the ground Do not erect the...

Page 13: ...he purlins using M10 X 80 mm bolts component code 10 as shown in Figures 7 8 9 and 10 There are five pieces of connection purlins be tween two group arches 3 Install the third arch and connect the connection purlins Install all the other arches in the same manner and connect the purlins as shown in Figures 9 and 10 4 Finally install the supporting tubes component code 5 between the first and last ...

Page 14: ...12 www hardlifeutility com Figure 9 C2620 Figure 10 C2640 ...

Page 15: ...ay it open on the ground parallel to the container shelter on one side NOTE The inner surface of the roof cover has pockets to insert the lower tensioning tubes 2 Insert the lower tensioning tubes for the roof cover component code 7 into the pockets that are at the base of the roof cover as shown in Figures 9 and 10 3 Plug both the ends of the lower tensioning tubes with the Ø32 plastic plugs for ...

Page 16: ...small slits in the cover pocket at the ends of the roof cover using a scissors for the ratchet tie down straps component code 13 to go through The cuts should be made exactly at the ratchet locations Loop the ratchet tie down strap around the lower tensioning tube through the cuts on the cover to secure the lower tensioning tube Pull the ratchet tie down straps through the reels of the ratchets wh...

Page 17: ...15 www hardlifeutility com Figure 13 C2620 Figure 14 C2640 ...

Page 18: ...own to the sides You can add rope length by tying pieces together or cutting the rope as necessary 9 Finally for the C2620 shelter tie the roof cover to the angle seats as shown in Figure 15 NOTE Ensure that you do not over tighten the lacings 10 Your assembly is now complete WARNING Never leave the roof cover unattached under any circumstances until the final assembly and tighten ing have been co...

Page 19: ...of fabric should ideally be retightened before the next winter Adjust the roof cover every month to ensure you always have a flat and tensioned roof cover Inspect the shelter regularly and replace damaged components Figure 16 NOTE Use duct tape to close the gaps in between the steel frame after installation of the shelter if required as shown in Figure 16 Duct tape is also used on some tube connec...

Page 20: ...18 www hardlifeutility com INSTALLATION PHOTOS ...

Page 21: ...19 www hardlifeutility com ...

Page 22: ...ving your payment subject to availability 5 YEAR SPARE PART REPLACEMENT Spare part availability for 5 years from the date of purchase EFFICIENT AFTER SALES SUPPORT Lifelong technical assistance for all our products CUSTOMISED SHELTERS Custom made tents manufactured to meet your requirements Write to us info hardlifeutility com Call us 44 01525 30 90 70 85 19 12 ...

Page 23: ...21 www hardlifeutility com ...

Page 24: ...22 www hardlifeutility com Unit 4 Dawson Road Bletchley Milton Keynes MK1 1LH United Kingdom Call us 44 01525 30 90 70 01525 85 19 12 ...