background image

PURE SINE WAVE INVERTER 

USER MANUAL

June 2020

Summary of Contents for HKPINV2000

Page 1: ...PURE SINE WAVE INVERTER USER MANUAL June 2020 ...

Page 2: ...ions Make sure at least 10CM of clearance around inverter for air flow Minimum air flow of 145CFM is required Make sure existing wiring is in good electrical condition DO NOT operate inverter with damaged or substandard wiring DO NOT install in compartments containing batteries or flammable materials or in locations which require ignition protected equipment DO NOT disassemble this inverter charge...

Page 3: ... HKPINVRC which will allow the inverter to be turned on off remotely Ideal for use in caravans motor homes and boats PROTECTION FEATURES Low input voltage High input voltage Low battery alarm Over temperature Overload protection HKPINV300 HKPINV600 HKPINV2000 PAGE 2 HARDKORR COM AU NZ 240VAC OUTLET PORT FOR INTERFACE interface not included EARTH CONNECTION ON OFF SWITCH COOLING FAN POSITIVE TERMIN...

Page 4: ...ours of energy needed Then multiply the average power consumption in watts by the number of hours of run time For example 1500 watts for 10 hours 15 000 watt hours Using the 1500 watts or 150 Amps for 10 hours example as above then 150 amps is needed for 10 hours This provides us with the basic amp hours AH of battery that is required Ten hours at 150 amps equals 1500 Amp Hours AH This answer is j...

Page 5: ...itive line as close to the battery as possible 3 Make sure the inverter is turned OFF 4 Connect the cables to the DC input terminals on the rear of the inverter The red terminal is positive and the black terminal is negative 4 Connect the positive cable to the inverter and battery positive terminals 5 Connect the negative cable to the inverter and battery negative terminals 6 Connect an insulated ...

Page 6: ...power overloading low battery voltage or voltage drop due to insufficient size cables or poor connections Q The Inverter will not run my appliance even though the appliance draws less power than the size of the inverter A The appliance draws more start up power than the inverter is able to produce Q Why does it damage the inverter if the battery leads are reverse connected A Your inverter uses sop...

Page 7: ...Size mm Weight kg Low Battery Voltage Alarm Shutdown Remote Standby Current Draw Alarm 10 5 VDC Shutdown 10 0 VDC 0 3 VDC Automatic Temperature Controlled Pure Sine Wave THD 3 10 5 15 VDC Blade Fuses 65 5 Internal HKPINV300 HKPINV600 HKPINV2000 12VDC 12VDC 12VDC 30A 60A 200A 500mA 500mA 900mA 1mA 1mA 240vac 1mA 300W 600W 2000W 600W 1200W 4000W 89 92 94 50A 2 25A 80A 4 20A 240A 4 60A 195 166 83 225...

Page 8: ...er s electrical systems This warranty does not apply to and HARDKORR will not be responsible for any defect in or damage to 1 The product if it has been misused neglected improperly installed physically damaged or altered either internally or externally or damaged from improper use or use in an unsuitable environment 2 The product if it has been subjected to fire water generalized corrosion biolog...

Page 9: ...mber supplied by HARDKORR clearly marked on the outside of the box A return address where the unit can be shipped Post Office Boxes may not be acceptable A contact phone number where you can be reached during work hours A brief description of the problem 3 Ship the unit prepaid to the address provided by your HARDKORR customer service representative If you are returning a product in addition to th...

Reviews: