background image

4

16C Low-Pressure Dead-Length Collet Blocks

 Instructions B-145

Hardinge Inc.  One Hardinge Drive, Elmira, New York U.S.A. 4902-507  800.843.880 (Canada 800.468.5946)   www.hardingetooling.com

Par

t No

. B -0009500-0

45

 

AIR SUPPLY

4-WAY, 2-POSITION

CONTROL VALVE

#7799-00-00-000071

AIR DRIVEN HYDRAULIC PUMP

1500 PSI   #7799-00-00-000070
2500 PSI   #7799-00-00-000069

PRESSURE

RETURN

CLAMP

UNCLAMP

HYDRAULIC

COLLET CLOSERS

(double-acting)

AIR SUPPLY

PRESSURE

RETURN

AIR DRIVEN HYDRAULIC PUMP

1500 PSI   #7799-00-00-000070
2500 PSI   #7799-00-00-000069

HYDRAULIC

COLLET CLOSERS

(double-acting)

ACCUMULATOR

#7799-00-00-000068

HORIZ MOUNT

#7799-00-00-000067

QUICK

DISCONNECT

HANDLE

#7799-00-00-000075

STD. MANIFOLD

WITH CHECK VALVE

#7799-00-00-000074

FIXTURE

PLATE

CLAMP

UNCLAMP

4-WAY, 3-POSITION

CONTROL VALVE

#7799-00-00-000072

Example of a typical hydraulic configuration

Components include a pump, control valve and three hydraulic collet blocks supplied by Hardinge mounted on a customer 
machined fixture plate. (schematic shown in clamp position) 5000 psi (344 bar) rated hose/tubing is recommended.

Dimensions for mounting holes are available on the installation instructions online at www.hardingetooling.com

Example of a quick disconnect hydraulic configuration 

Components include a pump, control valve, accumulator, quick disconnect handle, manifold with check valve and three 
hydraulic collet blocks supplied by Hardinge on a customer machined fixture plate.  The control valve should mount outside 
of the machine with the pump or on the outside wall of the machine.  The quick disconnect with check valve allows you to 
remove the hydraulics while in the clamp mode – ideal for preloading pallets. An accumulator is required when using the 
quick disconnect product. (Schematic shown in the clamp position) 5000 psi (344 bar) rated hose/tubing is recommended.

Dimensions for mounting holes are available on the installation instructions online at www.hardingetooling.com

Summary of Contents for 16C

Page 1: ...ssure of 250psi air or 1207 psi hydraulic 17 bar air 83 bar hydraulic Make sure that the collet retains your material when the closer is closed Application This 16C collet block is a stationary unit with a double acting cylinder It is effective on machine and assembly operations that require reliable clamping and unclamping Use the collet block as a single unit or mount multiple closers on rotary ...

Page 2: ...to this closer above 250 psi air or 1207 psi hydraulic 17 bar air 83 bar hydrualic may overstress the 5C collet 8 To open the collet actuate the valve Maintenance If over a period of time you experience a decrease in clamping force even though pneumatic or hydraulic pressure remains unchanged remove the collet block from service disassemble and replace any damaged or worn o rings Warranty The prod...

Page 3: ...ting AIR SUPPLY FIXTURE PLATE Example of a simple pneumatic configuration Components include a control valve and three pneumatic collet blocks supplied by Hardinge mounted on a customer machined fixture plate Two connector bushings are used between each collet block for internal plumbing A total of four connector bushings would be used in this example schematic shown in clamp position Dimensions f...

Page 4: ...mp control valve and three hydraulic collet blocks supplied by Hardinge mounted on a customer machined fixture plate schematic shown in clamp position 5000 psi 344 bar rated hose tubing is recommended Dimensions for mounting holes are available on the installation instructions online at www hardingetooling com Example of a quick disconnect hydraulic configuration Components include a pump control ...

Reviews: