background image

 
 
 
 

Page | 6 

MV SZSVS Variable School Zone Sign 

Aug 2023

 

 

No.  

Name 

Description 

 

Network interface-RJ45 

Ethernet interface for major network 

 

Console serial port 

TTL3.3V, to connect software 

 

Radar RS232+RS485 PORT 

RS232/RS48 port for customer to self-define 
CZ9281, switch P1 to choose RS232 or RS485 

 

PC RS232+RS485 PORT 

RS232/RS48 port for Customer to self-define 
CZ9281, switch P2 to choose RS232 or RS485 

 

Power port 

To connect with 4.6V-26V power input 

 

8 output control port 

To control wigwag 

 

Extended RS485 port 

For additional device 

 

LED panel port 

Connect to the LED Panel (EN port) 

 

FPGA download port 

2x3P FPGA download port 

 

10 

External voltage signal isolation input 

HGND: External voltage 
IN1-8:voltage input 

 

11 

Light sensor port 

To connect with environment light sensors; two 
can be connected. 

 

12 

Relay Port 

To connect relay and public terminal 

 

13 

Spare battery port 

 

 

14 

Hub board port 

Supply 5V power and GND, the max output 
7.5W 

 

15 

CPU Download port 

To download CPU program 

 

 

2.4.2     Other components  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MV 8616B 

4 pcs 

MV 8523 

4 pcs 

MV 3512 

2 pcs 

MV 8728B 

1 pcs 

MV 3225 

1 pcs 

MV 9281D 

1 pcs 

Summary of Contents for MV SZSVS

Page 1: ...Page 1 MV SZSVS Variable School Zone Sign Aug 2023 Version 1 0 VARIABLE SCHOOL ZONE SIGN Model MV SZSVS Operation Maintenance Manual ...

Page 2: ...Overview 4 2 1 Cabinet Specifications 4 2 2 Optical Characteristics 5 2 3 Electrical Characteristics 5 2 4 Major Components 5 3 Maintenance Guide 7 3 1 Maintenance Tool List 7 3 2 Preventative Maintenance 8 5 3 Cabinet Maintenance 8 4 Trouble Shooting 9 Release Change Version Release Date Initial Release 1 0 July 2023 ...

Page 3: ...lth and Safety All personnel involved in carrying out the work must be aware of any site working regulations and required certification Before taking any installation or maintenance action service personal must follow the above safe working practices Only allow sufficiently experienced personnel to do maintenance Provide sufficient illumination for the job especially during non daylight hours Wear...

Page 4: ... thickness 150mm Weight 30kg without Batteries Cabinet Material Aluminium Paint Colour Front Matt Black Rear Aircraft Grey Maintenance method Front Access CAUTION HEAVY EQUIPMENT The VMS should be adequately supported during installation replacement or maintenance All lifting and moving jobs must be performed by mobile crane or other suitable lifting device ...

Page 5: ...Electrical Characteristics Power supply 12V 24V DC Power consumption Max 50W Power consumption Average 20W Internal voltage LED boards 4 2VDC Internal voltage Controller 5VDC Max power consumption is only ever achieved within a manually initiated test Max power is with all LED s on in white and manually set to full brightness 2 4 Major Components 2 4 1 CPU Controller Card 9281 ...

Page 6: ... input 6 8 output control port To control wigwag 7 Extended RS485 port For additional device 8 LED panel port Connect to the LED Panel EN port 9 FPGA download port 2x3P FPGA download port 10 External voltage signal isolation input HGND External voltage IN1 8 voltage input 11 Light sensor port To connect with environment light sensors two can be connected 12 Relay Port To connect relay and public t...

Page 7: ...n challenging environments regular preventive maintenance is recommended By following these guidelines you can mitigate potential issues and extend the lifespan of your product CODE DESCRIPTION MV 8616B 1 2 ROUNDEL LED BOARD 800mm RED MV 8523 WIG WAG 70mm LED BOARD MV 3512 LED TILE PCB BOARD SZSVS MV 9281D VMS CPU MOTHER BOARD MV 3225 POWER PROTECTION BOARD MV 8728B DC DC BOARD MV 9136B A DC DC PO...

Page 8: ... receiving correct messages from the management system If not report fault to Harding Traffic Ltd Check if the door locks are secured tightly or any parts are broken If not insert the required key in the lock and turn clockwise to tighten or change the parts Check if all the cable glands are secured tightly If loose push in the gland and ensure they are secured connected 3 3 Cabinet Maintenance Be...

Page 9: ...ule with another to determine if the fault is related to the input or elsewhere Multiple modules are not working or have abnormal brightness Check the power supply to the modules Functional problem Optical sensor problem Check whether the Optical sensor connector is reliably connected to the CPU Controller Card Check whether the Optical Sensor wire is damaged Swap with another light sensor to conf...