background image

 

 

 

100 Series Intercom Stations 

Document IM- ICM-100-2.2 

 

 

1998 Harding Instruments - Printed in Canada 

 

 

INSTALLATION

 

MicroComm DXI

 

  

INSTRUCTIONS 

1. 

Intent & Scope 

This document describes the installation procedure for the 100 series intercom stations. 

2. 

Description 

The 100 series of intercom stations include all intercom stations that are designed to be connected to the system 
via an SAB-100 station audio board. Each 100 series intercom station is connected to the system with a single 
shielded twisted pair cable that carries all the microphone, loudspeaker, switch, and indicator signals. 
 

 

Intercom Station - Rear View 

 

3. 

Installation 

The intercom stations are connected to the exchange with a single shielded twisted pair. The shields are all 
grounded at the exchange end through the DB-50 connector and terminated through the BIX field interface block. 
They are all left open at the intercom station end of the cable. Where the cable is connected to another cable the 
shields must be continued from one cable to the other and care should be taken to ensure that the shields on the 
different signal pairs are not connected together. 

The connections to the intercom station are made with an AMP MTA-100 series connector. The intercom pair 
should connect to pins 1 and 2 on the intercom station. To make these connections you should use an AMP tool 
58074-1 with a 58246-1 head. The cable should be cut to length and the shield and outer jacket should be trimmed 

pin 1 

Summary of Contents for MicroComm DXI 100 Series

Page 1: ...e intercom stations are connected to the exchange with a single shielded twisted pair The shields are all grounded at the exchange end through the DB 50 connector and terminated through the BIX field interface block They are all left open at the intercom station end of the cable Where the cable is connected to another cable the shields must be continued from one cable to the other and care should ...

Page 2: ...dspeaking function It still contains a call switch and an internal microphone for audio input signals The perforated area where the loudspeaker normally resides is deleted Installation of the unit is similar to any other intercom station The only difference is that pigtail leads are provided for connection to the horn loudspeaker Note that the horn loudspeaker requires a 25 volt line matching tran...

Page 3: ... with the low clearance outer edges of the loudspeaker or loudspeaker whizzer cone Once the proper mounting location has been determined mark the shock mount mounting holes and use a 3 32 bit to drill approximately 3 16 into the baffle grid members Mount the microphone shock mount with two 4 x 3 8 self tapping screws Microphone Shock Mount Installation After the microphone shock mount has been ins...

Page 4: ...lcro and gently press the talkback kit on to a convenient mounting location on the loudspeaker cone frame as in the following illustration Talkback Kit Installation Complete Finally make the electrical connections to the talkback kit for the loudspeaker and optional switches The loudspeaker connection must be made through a 25 volt matching transformer at a power tap not exceeding one watt The fol...

Page 5: ...reen Speaker Yellow Switch 1 Yellow Switch 1 Red Switch 2 Red Switch 2 The intercom talkback unit is connected to a station audio board the same as any other intercom station via the MTA connector The following table gives the pin configuration for the MTA connector MTA Pin Signal 1 audio 2 audio 3 N C 4 N C ...

Reviews: