background image

 

 

ICM-400 Series Intercom Stations 

Document IM-ICM-400-2.14 

 

 

1999 Harding Instruments - Printed in Canada 

1. 

Intent & Scope 

This document describes the installation procedure for the ICM-400 series intercom stations. The ICM-400 series 
intercom stations include intercom stations types ICM-420, ICM-421, ICM-430, ICM-431, and ICM-490. The ICM-
4x1 stations include a LED while the ICM-4x0 stations do not. The ICB-400 Intercom Board is used to convert a 45 
ohm loudspeaker into a 400 series intercom station. Included is a description on connecting an ICM-420 and ICM-
320 to create a two sided door primary/secondary pair 

2. 

Description 

The ICM-400 series of intercom stations include all intercom stations that are connected to a DXI  system via a 
SAB-400 or SAB-401 station audio board, or to a DXL system via a SCC-400 or SCC-401 station control card. Each 
ICM-400 series intercom station is connected to the system with a single shielded twisted pair cable that carries all 
the microphone, loudspeaker, switch, and LED indicator signals. 

The ICM-400 series intercom stations can be ordered in several configurations. These include: 

(i)

 

0, 1 or 2 switches. These switches are mounted on the faceplate and internally terminated. They can be 
used for call request, program music selection, or other functions. The terminations allow the system to 
detect open or short line faults.  

The switch information is multiplexed with the audio signals over a single pair of wires. 

(ii)

 

The LED stations, ICM-421 and ICM-431, are used with SAB-401 station audio board or SCC-401 station 
control card. The LED is used  to  indicate call request status or active call status. Again LED status 
information is multiplexed over the audio pair. 

(iii)

 

A cord jack can be specified in place of the standard faceplate switch on the intercom stations. 

(iv)

 

An Apem switch,  red mushroom button switch or mini-piezo switch can be ordered for the intercom 
stations. 

(v)

 

A piezo-electric switch can be specified in place of the standard faceplate switch on the ICM-430 or ICM-
431  

(vi)

 

The switch contacts of a switch can be made available on a four-pin header. With external field wiring the 
switch can then be used to operate an external device, i.e. open a door; turn on lights, etc. External 
contacts can also be connected to this four-pin header. This allows external equipment to activate the 
station switches and place call requests or act as a switch to change the music selection. 

Summary of Contents for dxi MicroComm ICM-400 Series

Page 1: ...e include i 0 1 or 2 switches These switches are mounted on the faceplate and internally terminated They can be used for call request program music selection or other functions The terminations allow the system to detect open or short line faults The switch information is multiplexed with the audio signals over a single pair of wires ii The LED stations ICM 421 and ICM 431 are used with SAB 401 st...

Page 2: ...ICM 400 Series Intercom Stations Page 2 Document IM ICM 400 2 14 vii The ICB 400 Intercom Board kit is used to convert a 45 ohm loudspeaker into a 400 type of intercom station ...

Page 3: ...when Switch B is to provide an external contact closure The switch contacts are connected to pins 1 and 2 of the header CN3 Header CN4 is used when Switch A is to provide external switch contacts The switch contacts are connected to pins 1 and 2 of the header CN4 Remote contact closures can be transmitted to the system through pins 3 and 4 of CN3 and CN4 The possibility of inserting a header label...

Page 4: ... a CBL 190 cable to the SAB 400 or SAB 401 All shields are terminated at the field interface teminal block The shields are grounded through the cable that connects the terminal block to the DB 37 connector on the SAB 400 a CBL 190 cable Note the CBL 190 cable has 3 wires that are connected to ground on the SAB 400 401 See IM DXI REF MAR05 The shields are left open at the intercom station end of th...

Page 5: ...es Intercom Stations Document IM ICM 400 2 14 Page 5 jacket should be trimmed back about 1 2 inch Ensure that the shield is not exposed or it may short out exposed contacts on the intercom PCB when it is installed ...

Page 6: ...led CN3 is the header for Switch B and CN4 is the header for Switch A The external switch connections to the header s are made with a female 4 pin AMP MTA 100 series connector MTA Pin Signal 1 Switch 1Out 2 Switch 1 Out 3 Switch 1 In 4 Switch 1 In 4 ICB 400 Intercom Board Talkback Kit The ICB 400 is used to convert a 45 ohm loudspeaker into an intercom station The ICB 400 can be used with a 45 ohm...

Page 7: ... If the circuit board is not encased in the non conductive heat shrink it can be mounted using the two 0 125 diameter holes shown in the above diagram You may have to use standoffs to insure all components have suitable clearance If the circuit board of the talkback kit is encased in the optional non conductive heat shrunk case then it is attached with two strips of Velcro mounted on the back Remo...

Page 8: ...of 25 V 10 watts will give an output of 0 97 watts into an 8 ohm speaker while a transformer tap setting of 25 V 5 watts will provide an output of 0 77 watts The pigtail leads for the speaker and switch connections of the ICB 400 Intercom Board Talkback Kit are color coded as follows Wire Signal Green Spkr Black Spkr Yellow Switch B In Yellow Switch B In Orange Switch A In Orange Switch A In The i...

Page 9: ... B Out Sw B In Switch B Out Switch A In Switch A Out Switch A In Switch A Out SWB SWA CN1 CN2 CN3 CN4 Spkr Spkr 2001 Harding Instrument Co Ltd PC06713 04 CN1 Switch A In 3 Switch A Out Switch A Out CN4 1 2 2001 Harding Instrument Co Ltd 7 CN2 Switch A In Switch B Out Sw B In Switch B Out Switch B In CN3 1 4 3 2 4 4 2 1 3 5 6 Aud Aud Aud Aud 4 9 8 10 Spkr Spkr 2 3 1 SWA SWB PC06713 04 Primary ICS 4...

Page 10: ...tations NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor...