7.1
In cases where breakdowns have occurred, the same factors always seem to come into play:
1. Minor leaks on the suction side of the pump will reduce the pump capacity or stop the suction completely.
2. A clogged suction filter will hinder or prevent suction so that the pump does not operate satisfactorily.
3. Clogged up pressure filters will result in increasing pressure at the pressure gauge but lower pressure at the nozzles.
4. Foreign bodies stuck in the pump valves with the result that these cannot close tightly against the valve seat. This
reduces pump efficiency.
5. Poorly reassembled pumps, especially diaphragm covers, will allow the pump to suck air resulting in reduced or no
capacity.
6. Hydraulic components that are contaminated with dirt result in rapid wear to the hydraulic system.
Therefore ALWAYS check:
1. Suction, pressure and nozzle filters are clean.
2. Hoses for leaks and cracks, paying particular attention to suction hoses.
3. Gaskets and O-rings are present and in good condition.
4. Pressure gauge is in good working order. Correct dosage depends on it.
5. Operating unit functions properly. Use clean water to check.
6. Hydraulic components are maintained clean.
Ge
n
e
r
al
in
f
o
Ope
r
a
tion
al p
rob
lem
s
7 - Fa
u
l
t
f
in
d
in
g
Summary of Contents for ZENIT
Page 1: ...ZENIT Instruction book 67302603 Version 1 01 US 02 2008 ...
Page 2: ......
Page 4: ......
Page 8: ...Table of contents TOC 4 Table of contents TOC 4 ...
Page 10: ...1 Welcome 1 2 ...
Page 14: ...2 Safety notes 2 4 ...
Page 32: ...4 Sprayer setup 4 6 ...
Page 44: ...5 Operation 5 12 ...
Page 63: ......