10
T165-0005
T165-0006
5-7 mm
5-7 mm
Optional transducers
Revolutions and area-meter transducer
The south side of the magnet
must face the transducer.
Distance between them must
be 5 to 7 mm.
An adjustable hose clamp
drilled with a 4.5 mm hole can
be used to attach the magnet
to the shaft.
Analog transducer
This is for example a pressure
transducer.
Input is 4 to 20 mA.
Transducer cables are fed through the grommets. Connection is directly to the
junction box circuit board.
Cables
All the cables and wires must be routed so they do not get pinched, snagged
or melted.
NOTE:
An extension cable is available as an option if the computer is to be
placed further away from the Spray control box. (Ref. no. 261933)
NOTE:
Although the system meets standards EN 50081-1 (1992) for generic
emission and EN 50082-2 (1995) for generic immunity, some communication
systems (e.g. 2 way radio, cellular telephones) may cause interference with the
sprayer computer. Keep communication system units and cabling away from
the sprayer computer units and cabling. If interference is noted, avoid using the
communication system.