4 - Sprayer setup
45
Electrical connections
Road Safety Kit
Connect the plug for rear lights to the tractor’s 7-pin socket and check the function of rear lights, stop lights, side lights and
direction indicators on both sides before driving.
The wiring is in accordance with ISO 1724. See the section “Technical Specifications”.
μ
ATTENTION! Turn OFF all work lights when driving on public roads!
Power Supply
Power requirement is 12 V DC. Always note polarity! For proper function
of the electric equipment, the wires must have the following
recommended cross sectional areas and correct fuses to ensure a
sufficient power supply.
The delivered power connectors follows the standard of most modern
tractors. If you have a tractor with another power connector, it is
necessary to disassemble the connector and fit it to the actual tractor
connector.
The number and the type of connectors may vary on the specific
sprayer, depending on its equipment.
Cigar connector, 1-pin
Spray control unit requires:
Wire 2.5 mm
2
. Fuse 10 amps.
Hydraulic control unit requires:
Wire 4.0 mm
2
. Fuse 16 amps.
Traffic light connector, 7-pin
The unit requires:
Wire 6 x 1.5 mm
2
+ 1 x 2.5 mm
2
The cable is custom made and must not be
changed to another type.
EVC Spray Box connector, 39-pin
The unit requires:
Wire 39 x 1.0 mm
2
The cable is custom made and must not be
changed to another type.