3 - Description
3.4
ATTENTION! Only the functions in use should be open - always close remaining valves.
ATTENTION! If a MANIFOLD valve is too tight to operate - or to loose (= liquid leakage) - the valve needs to be ser-
viced. Please see the section ‘Maintenance’ for further information.
Suction from main tank
Filling of main tank
All functions of the spray circuits are operated via the centrally situated MANIFOLD with colour coded pictorial symbols
for easy operation.
A diaphragm pump with 6 diaphragms, model 463, with easily accessible valves and diaphragms. Standard = 540 r.p.m.
(6 splines). Optional = 1000 r.p.m. (21 splines).
The CM 6600 can be equipped with FlexCapacity pump system. The FlexCapacity pump system consists of standard
463/12 pump which is set up as in a standard system with PTO drive. Furthermore the system is added a 463/10 pump
driven by a hydraulic motor. The hydraulic motor is supplied from a seperate outlet on the tractor and can therefore be
turned on/off independently when needed.
The valves at the MANIFOLD are distinguished by coloured identification on the function labels. Symbols corresponding
to every possible function of use are located on the discs for easy identification and operation. A function is activated by
turning the handle towards the desired function.
Suction from rinsing tank
Spraying
Suction from external tank
Internal tank cleaning
Pressure emptying
The active function is indicated by the indicator.
The active function is indicated by the indicator.
Pressure valve = Green symbols
Suction valve = Blue symbols
Valves and symbols
FlexCapacity pump system (optional equipment)
Pump
General info - MANIFOLD system
LookAhead Liquid system
Summary of Contents for COMMANDER TWIN FORCE Series
Page 8: ...Table of contents TOC 6 ...
Page 10: ...1 CE Declaration 1 2 ...
Page 14: ...2 Safety notes 2 4 ...
Page 66: ...6 Maintenance 6 2 Boom lubrication oiling plan 32 36 m ...
Page 67: ...6 Maintenance 6 3 Trailer lubrication oiling plan ...
Page 107: ...8 Technical specifications 8 11 Charts Boom hydraulic Y Boom hydraulic Z ...
Page 108: ...8 Technical specifications 8 12 Sprayer hydraulic Fan transmission ...
Page 109: ...8 Technical specifications 8 13 Electrical specifications for boom and work light ...
Page 110: ...8 Technical specifications 8 14 ...