For technical questions, please call 1-888-866-5797.

ITEM 59134 

        

SAFETY

SETU
p

Op
ERA
TION

M

AINTENANCE

Spark plug Maintenance

1.  Disconnect spark plug cap from end of plug.  

Clean out debris from around spark plug.

2.  Using a spark plug 

wrench, remove 

the spark plug.

3.  Inspect the spark plug: 

If the electrode is oily, 

clean it using a clean, 

dry rag. If the electrode 

has deposits on it, 

polish it using emery 

paper. If the white 

insulator is cracked or 

chipped, the spark plug needs to be replaced.

NOTICE:

 Using an incorrect spark plug may 

damage the engine.  See the Specifications chart 

for your Generator for the type and gap required.

4.  When installing a new spark plug, adjust 

the plug’s gap to the specification on the 

Specifications chart.  Do not pry against the 

electrode, the spark plug can be damaged.

5.  Install the new spark plug or the cleaned spark plug 

into the engine.  Gasket-style:  Finger-tighten until 

the gasket contacts the cylinder head, then about 

1/2-2/3 turn more. 

Non-gasket-style: Finger-tighten until the plug 

contacts the head, then about 1/16 turn more.

NOTICE:

 Tighten the spark plug properly.  

If loose, the spark plug will cause the engine 

to overheat.  If overtightened, the threads 

in the engine block will be damaged.
6.  Apply dielectric spark plug boot protector 

(not included) to the end of the spark plug 

and reattach the wire securely.

Spark Arrestor Maintenance

1.  Wait for Engine exhaust and 

Muffler to cool completely.

2.  Remove Spark Arrestor from end of exhaust.

3.  Brush all carbon off Spark Arrestor using 

a stiff brush (sold separately).

4. 

WARNING! TO pREVENT SERIOUS INJURY 

FROM ACCIDENTAL BRUSH FIRE, secure 

Spark Arrestor back in place immediately 

after cleaning and before further operation.

Long-Term Storage

When the equipment is to remain idle for longer than 

20 days, prepare the Engine for storage as follows:
1. 

CLEANING

Wait for Engine to cool, then clean Engine with 

dry cloth.  

NOTICE:

  

Do not clean using water.

  

The water can cause rust damage over time.  Apply 

a thin coat of rust preventive oil to all metal parts.

2. 

FUEL: 

Gasoline Treatment/Draining the Fuel Tank 

 

To protect the fuel tank during storage, fill the 

tank with fresh gasoline that has been treated 

with a fuel stabilizer additive.  Follow fuel 

stabilizer manufacturer’s recommendations 

for use.  Refer to Checking and Filling Fuel 

Checking and Filling Fuel on page  11.

Aged gasoline that has not been treated with 

stabilizer ahead of time must be safely drained 

away and not run through the engine.

WARNING!

 

TO pREVENT SERIOUS 

INJURY FROM FIRE:

 

Fill tank in a well-ventilated area away 

from ignition sources.  If the engine 

is hot from use, shut the engine off and 

wait for it to cool before adding fuel.  Do not smoke. 

 

Draining the Carburetor

After closing the Fuel Valve, place an appropriate 

container under the Carburetor and carefully 

remove the Drain Bolt from the bottom of the 

Carburetor Bowl, allowing the fuel to drain 

completely.  Replace the Drain Bolt after draining.

WARNING! To prevent serious 

injury and fire, close the Fuel Valve 

before draining the Carburetor.

3. 

LUBRICATION:

a.  Change engine oil.
b.  Clean out area around spark plug.  

Remove spark plug and pour one tablespoon of 

engine oil into cylinder through spark plug hole.

c.  Replace spark plug, but leave 

spark plug cap disconnected.

d.  Pull Starter Handle to distribute oil in cylinder.  

Stop after one or two revolutions when you 

feel the piston start the compression stroke 

(when you start to feel resistance).

Cylinder 

Assembly

Spark 

plug 

Summary of Contents for PREDATOR 59134

Page 1: ...ence 22f Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 a...

Page 2: ...aken Access shall be through the use of a special tool or lock and key or other means of security and shall be controlled by the authority responsible for the location 2 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 3 Have multiple ABC class fire extinguishers nearby 4 Operation ...

Page 3: ...allow carbon monoxide to accumulate FLASHING RED LIGHT Dangerous levels of carbon monoxide gas have built up and generator will shutoff Leave immediately until area has aired out Move Generator to well ventilated area before operation FLASHING YELLOW LIGHT Carbon monoxide sensor malfunction Sensor needs service Do not use the Generator until the sensor is working properly For technical questions p...

Page 4: ...eplaced f Press Reset button in for use The Generator must be grounded before use An ungrounded Generator has an increased risk of electric shock Refer to Grounding on page 9 19 Insulate all connections and disconnected wires 20 Guard against electric shock Prevent body contact with grounded surfaces such as pipes radiators ranges and refrigerators 21 Only use a suitable means of transport and lif...

Page 5: ...f moving parts breakage of parts and any other condition that may affect the Generator s operation If damaged have the Generator serviced before using Many accidents are caused by poorly maintained equipment 42 Use the correct generator for the application Do not modify the generator or its engine and do not use the generator for a purpose for which it is not intended 43 Extension Cord Make sure y...

Page 6: ...orrectly 9 Store equipment out of the reach of children 10 Follow scheduled engine and equipment maintenance GFCI Protection This Generator is equipped with two 3 Prong duplex 120V ground fault circuit interrupter GFCI receptacles These outlets provide additional protection from the risk of electric shock Should replacement of the receptacles become necessary use only identical replacement parts t...

Page 7: ...oline Capacity 7 79 Gallon 29 50 Liter Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 Quart Spark Plug Type NHSP Torch F6TC Gap 0 028 0 031 Valve Clearance Intake 0 004 0 006 Exhaust 0 004 0 006 Run Time 50 load Up to 13 hr Available accessories Wheel kit sold separately The emission control system for this Generator s Engine is warranted for standards set by the U S Envir...

Page 8: ...eptacle 120 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used ON OFF 3 Circuit Breakers The circuit breaker protects the Generator from overloading The rating of the breaker and the load it protects are marked near the breaker Should any of the Circuit Breakers trip the Generator will stop the electricity output If th...

Page 9: ... intended to power sensitive electronic equipment without the addition of an appropriate line conditioner and surge protector both not included Sensitive electronic equipment includes but is not limited to audio video equipment some television sets computers and printers Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators Wheel Kit 64...

Page 10: ...ons are as follows Use one of the following as the grounding electrode Pipe or conduit minimum in diameter minimum 8 ft long If steel it must have anti corrosion coating Rod stainless steel or copper or zinc coated steel minimum 5 8 in diameter minimum 8 ft long 1 Drive electrode at least 8 ft vertically into the ground a If rock layer prevents vertical entry drive at an angle not exceeding 45 deg...

Page 11: ...owl under the fuel cup to catch any spilled fuel 5 Unthread the screws holding the solenoid in place CAUTION Carburetor bowl may have gas in it which will leak upon removing the solenoid bolt 6 Disconnect the solenoid and solenoid seal from the bolt 7 Unthread the bolt holding the fuel cup 8 Remove the bolt Bolt Seal fuel cup Fuel Cup Seal and Main Jet from the body of the carburetor assembly A ca...

Page 12: ...hout threading it in and remove it to check the oil level The oil level should be up to the full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recommended for general use The SAE Viscosity Grade chart on page in the Service section shows other viscosities to use in different average t...

Page 13: ... If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5 When finished using the Generator disconnect all electrical loads Note Do not allow Generator to run out of fuel with loads attached 6 Turn off the Engine 7 Allow the Generator and its Engine to comp...

Page 14: ...at the engine can stabilize For MANUAL START A Turn the Engine Switch to ON B Grip the Starter Handle of the Engine loosely and pull it slowly several times to allow the gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle sna...

Page 15: ...e rated capacity for this Generator as serious damage to the Generator and or appliances tools and equipment could result from an overload Starting and running wattage requirements should always be calculated when matching this Generator s wattage capacity to the appliance tool or equipment Use the DC12V Receptacle to power 12VDC equipment WARNING TO PREVENT SERIOUS INJURY Do not charge batteries ...

Page 16: ...or that only supplies the exact watts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate of additional Start up Watts For most lights or heaters there are no additional start up watts Wattage Estimate Charts Note Watta...

Page 17: ...ngine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off the Engine turn off all electrical loads then unplug them 2 Turn the Engine Switch off 3 Close the Fuel Valve I O START OFF RESET TEST RESET TEST I O START OFF ...

Page 18: ...a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems immediately The maintenance needs of each piece of equipment will differ depending on factors such as duty cycle temperature air quality fuel quality and other factors...

Page 19: ... Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the area around it Remove the Dipstick by threading it counterclockwise and wipe it off with a clean lint free rag 7 Full Level Full Level Add the appropriate type of oil until the oil level is at the full level SA...

Page 20: ...or back in place immediately after cleaning and before further operation Long Term Storage When the equipment is to remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait for Engine to cool then clean Engine with dry cloth NOTICE Do not clean using water The water can cause rust damage over time Apply a thin coat of rust preventive oil to all metal parts 2 FU...

Page 21: ...exposure to rain and sunlight NOTICE During extended storage periods the Engine must be started every 3 months and allowed to run for 15 20 minutes or the Warranty is VOID 6 AFTER STORAGE Before starting the Engine during or after storage keep in mind that untreated gasoline will deteriorate quickly Drain the fuel tank and change to fresh fuel if untreated gasoline has been sitting for a month if ...

Page 22: ...Filter IGNITION SPARK RELATED 1 Power Switch at OFF position 2 Spark plug cap not connected securely 3 Spark plug electrode wet or dirty 4 Incorrect spark plug gap 5 Spark plug cap broken 6 Circuit breaker tripped electric start models only 7 Incorrect spark timing or faulty ignition system IGNITION SPARK RELATED 1 Turn Power Switch to ON 2 Connect spark plug cap properly 3 Clean spark plug 4 Corr...

Page 23: ...ly operate generator outside 2 Carbon monoxide sensor malfunction Sensor needs service Call 1 888 866 5797 as soon as possible Do not use the Generator until the sensor is working properly 3 Make sure to operate generator within rated ambient temperature maintain minimum 5 ft clearance from all sides 4 Fill engine oil to proper level Check engine oil before EVERY use 5 Fill fuel tank with fresh 87...

Page 24: ...ker Plug in product and turn on 3 Turn off and unplug product Test GFCI receptacle If functioning properly reset GFCI plug in product and turn on 4 Have product repaired Product begins to operate abnormally 1 Problem with appliance 2 Rated load capacity exceeded 1 Immediately unplug appliance Have appliance repaired by a qualified technician or replace appliance 2 Lower the number of items plugged...