check for damaged parts

8. 

.  Before 

using any tool, any part that ap-

pears damaged should be carefully 

checked to determine that it will oper-

ate properly and perform its intended 

function. Check for alignment and 

binding of moving parts; any broken 

parts or mounting fixtures; and any 

other condition that may affect proper 

operation. Any part that is damaged 

should be properly repaired or re-

placed by a qualified technician. Do 

not use the tool if any switch does not 

turn On and Off properly.

replacement parts and acces-

9. 

sories

.  When servicing, use only 

identical replacement parts. Use of 

any other parts will void the warranty. 

Only use accessories intended for 

use with this tool. Approved accesso-

ries are available from Harbor Freight 

Tools.

Do not operate tool if under the in-

10. 

fluence of alcohol or drugs

.  Read 

warning labels on prescriptions to 

determine if your judgment or reflex

-

es are impaired while taking drugs. If 

there is any doubt, do not operate the 

tool.

Maintenance

11. 

.  For your safety, main-

tenance should be performed regu-

larly by a qualified technician.

People with pacemakers should con-

12. 

sult their physician(s) before using 

this product.  Electromagnetic fields 

in close proximity to a heart pace-

maker could cause interference to, or 

failure of, the pacemaker.
WARNING: Handling the cord on 

13. 

this product will expose you to lead, 

a chemical known to the State of 

California to cause cancer, and birth 

defects or other reproductive harm. 

Wash hands after handling. 

(California Health & Safety Code § 

25249.5, 

et seq.

)

Warning: the warnings, cautions, 

14. 

and instructions discussed in this 

instruction manual cannot cover 

all possible conditions and situ-

ations that may occur. it must be 

understood by the operator that 

common sense and caution are 

factors which cannot be built into 

this product, but must be supplied 

by the operator.

unpacKing

When unpacking, check to make 

sure all parts shown on the Parts Diagram 

and Parts Lists are present.  If any parts 

are missing or broken, please call Harbor 

Freight Tools at 1-800-444-3353.

preparing to operate

assembly

Figure 1

Figure 2

1.  Turn the lock nut on the stem clock-

wise to loosen (see Figure 1).
Adjust the length of the stem so that 

2. 

when you stand upright with the tool 

held in your hand, the search coil is 

level with and about 1/2 to 2 inches 

above the ground (see Figure 2).

reV 07f; 09c

Summary of Contents for 43149

Page 1: ...0 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Too...

Page 2: ...ld cause per sonal injury Do not use this product in areas where there might be under ground electric lines or pipes buried at shallow depths Never search in military zones where bombs or other explos...

Page 3: ...u larly by a qualified technician People with pacemakers should con 12 sult their physician s before using this product Electromagnetic fields in close proximity to a heart pace maker could cause inte...

Page 4: ...e way Never force the plug the plug could become dam aged To disconnect the plug never pull on the cable always take hold of the plug and pull it out of the connec tor Loosen the knob at the search co...

Page 5: ...hat can damage electronic parts If you do not plan to use the Tool for a week or more remove the batteries Use only fresh batteries of the required size Do not mix old and new batteries or different t...

Page 6: ...n Non ferrous metals do not examples gold silver copper platinum aluminum lead and zinc When the Tool senses a metallic object the meter reading changes and the de tector might sound a tone The reacti...

Page 7: ...re 17 Note Never test on a floor inside a build ing as it may have a type of metal present Set 2 MODE to TR1 Move a sample of the material being tested example coin or gold ring about 2 inches above t...

Page 8: ...he detector time to reset You can also press the red button on the handle to return the pointer to the center of the viewmeter Fine Tuning Once you practice with the unit you can fine tune it to make...

Page 9: ...nal This will prevent you from wasting time focusing on trash induced signals No metal detector is totally accurate Many conditions influence the success of metal detection Among the factors that infl...

Page 10: ...should only be performed by a qualified technician Part Description Mfr s Part No 1 Control Box Top SQC6 116 042 2 Meter M3006 3 Loud Speaker YD 50 16 ohm 0 25 W 4 Fixing Board SQC8 610 154 5 Screws...

Page 11: ...SKU 43149 For technical questions please call 1 800 444 3353 Page 11 Parts Diagram...

Reviews: