Lowes.com/harborbreeze
18
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Excessive
wobbling.
1. Blades are loose.
2. Blade arms incorrectly attached.
3. Unbalanced blades.
4. Fan not securely mounted.
5. Fan too close to vaulted ceiling.
6. Set screw(s) on motor housing yoke
is (are) not tightened properly.
7. Set screw on hanging ball is not
tightened properly.
1. Tighten all blade screws.
2. Re-install blade arms.
3. Switch one blade with a blade
from the opposite side or use
balancing kit (K).
4. Turn power off. Carefully loosen
canopy and verify that mounting
bracket is secure.
5. Use a longer downrod or move
fan to another location.
6. Tighten yoke set screw(s)
securely.
7. Carefully loosen and lower
canopy and verify that set screw
on hanging ball is tightened
securely.
TROUBLESHOOTING
Fan operates but
lights fail.
1. Bulb(s) not installed correctly.
2. Wires in canopy not wired properly.
3. Wall switch to light is off.
4. Wires in light kit fitter not wired
correctly.
5. Light kit is lamped with more than
the allowable 190W, causing the
wattage limiting device to interrupt
the flow of electricity to the light kit.
1. Re-install bulb(s).
2. Check wires in canopy and, if
necessary, re-wire according to
instructions on pages 11 - 12.
3. Make sure that wall switch to light
is on.
4. Check that molex connections in
light kit fitter are connected
properly according to instructions
on page 14.
5. Lamp light kit with bulbs that total
no more than 190W.