background image

39

Lowes.com/harborbreeze

CABLEADO

1B .

 VENTILADOR CONTROLADO POR CADENA DE 

TIRO Y LUZ CONTROLADA POR INTERRUPTOR 

DE PARED:

 para controlar el ventilador mediante 

cadenas de tiro y la luz con un interruptor de pared 

separado, conecte el cable negro del ventilador con 

el cable negro del techo . Conecte el cable azul del 

ventilador al cable negro del interruptor de pared para 

la luz . Conecte el cable blanco del ventilador al cable 

blanco del techo . Conecte todos los cables de tierra 

(verdes) juntos desde el ventilador al cable desnudo 

o verde del techo .  Asegure todas las conexiones del 

cableado junto con los conectores de cables (DD) .

Aditamentos utilizados

DD

Conector 

de cables

x 4

BLANCO

BLANCO

NEGRO

NEGRO

NEGRO (INTERRUPTOR DE PARED)

AZUL

Alimentación

de 120 V

DESDE

EL TECHO

VENTILADOR

DESDE EL VENTILADOR

DE TIERRA/VERDE (DESNUDO)

1B

1C .

 VENTILADOR Y LUZ CONTROLADOS POR DOS 

INTERRUPTORES DE PARED:

 para controlar 

el ventilador y la luz con interruptores de pared 

separados, conecte el cable negro del ventilador 

al cable negro del interruptor de pared para el 

ventilador . Conecte el cable azul del ventilador 

al cable negro del interruptor de pared para la luz . 

Conecte el cable blanco del ventilador al cable 

blanco del techo . Conecte todos los cables de tierra 

(verdes) juntos desde el ventilador al cable desnudo 

o verde del techo . Asegure todas las conexiones del 

cableado junto con los conectores de cables (DD) .

Nota:

  El cable negro le proporciona energía al 

ventilador . El cable azul le proporciona energía 

al kit de iluminación . El cable blanco es el cable 

común para el ventilador y el kit de iluminación . 

El cable verde (desnudo) es de tierra . 

Aditamentos utilizados

DD

Conector 

de cables

x 4

BLANCO

BLANCO

NEGRO (INTERRUPTOR DE PARED)

NEGRO

NEGRO (INTERRUPTOR DE PARED PARA LA LUZ)

AZUL

Alimentación

de 120 V

DESDE

EL TECHO

VENTILADOR

DESDE EL VENTILADOR

DE TIERRA/VERDE (DESNUDO)

1C

Summary of Contents for LANSING 40198

Page 1: ...retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday 1 ATTACH YOUR RECEIPT HERE Serial Number _________________________ Purchase Date...

Page 2: ...tion 5 Preparation 6 Assembly Instructions 7 Standard or Angled Mounting Instructions 9 Closemount Instructions 12 Wiring 13 Final Installation 16 Light Kit Installation 18 Operating Instructions 20 C...

Page 3: ...S A E I B F J C G K D H PART DESCRIPTION QUANTITY A Downrod 1 B Canopy 1 C Mounting Bracket 1 D Light Kit Fitter 1 E Motor Assembly 1 F Yoke Cover 1 G Blade Arm 5 H Blade 5 I Glass Shade 3 J Bulb 3 K...

Page 4: ...sion Qty 2 Downrod Pin preassembled to Downrod A Qty 1 Downrod Clip preassembled to Downrod A Qty 1 Motor Housing Set Screw preassembled to Motor Assembly E Qty 2 Closemount Screw preassembled to Moto...

Page 5: ...full range dimmer switch to control the fan speed WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an out let box marked ACCEPTABLE FOR FAN SUPPORT and use the mo...

Page 6: ...hat all parts are present Compare all parts with the package contents list and hardware contents list If any part is missing or damaged do not attempt to assemble the product After opening the top of...

Page 7: ...serious injury or death 1 2 Determine the mounting methods to use Note Flushmount installation is not available for this item Important If using the angle mount check to ensure the ceiling angle is no...

Page 8: ...rdware when installing the mounting bracket C as this will support the fan Important If using the angle mount ensure that the open end of the mounting bracket C is installed facing the higher point of...

Page 9: ...8 ft or higher For taller ceilings you may want to use a longer downrod not included Angle style mounting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensu...

Page 10: ...E Hardware Used FF Downrod Pin x 1 GG Downrod Clip x 1 HH Motor Housing Set Screw x 2 F GG HH FF E A 3 4 Depending on the length of downrod A you use you may need to cut the lead wires back to simpli...

Page 11: ...lack blue if applicable and green wires Important If you did not cut back the lead wires in Step 4 Step 5 is not necessary and you may proceed to Step 6 5 6 Install the ball end of the downrod A into...

Page 12: ...od hanging ball and canopy cover are not used in this type of installation 1 K B 2 Align the canopy B with the holes in the top of the motor assembly E Secure the canopy B to the top of the motor asse...

Page 13: ...and Blue wires from the fan to the Black wire from the ceiling Connect the White wire from the fan to the White wire from the ceiling Connect all Ground Green wires together from the fan to the Bare G...

Page 14: ...ct all Ground Green wires together from the fan to the Bare Green wire from the ceiling Secure all wiring connections together with wire connectors DD Note The Black wire is hot power for the fan The...

Page 15: ...push the wires and wire connectors DD into the outlet box WARNING Ensure that no bare wire or wire strands are visible after making connections Place the Green and White wire connections on opposite s...

Page 16: ...screws JJ and rotate clockwise Hardware Used JJ Mounting Bracket Screw x 4 B JJ 1 C 2 Secure the canopy B with the previously removed mounting bracket screws JJ and securely tighten all four mounting...

Page 17: ...ddle Repeat this step for the remaining blades H and blade arms G Hardware Used BB Blade Screw x 15 CC Blade Washer x 15 BB H G CC H 3 4 Align a blade arm G and a blade isolator LL with two holes unde...

Page 18: ...the light kit fitter D matching the colors on each plug Ensure that the plugs connect tightly Hardware Used KK Plate Screw x 3 D E 1 KK E 2 Align holes in the light kit fitter D with the holes in the...

Page 19: ...lease allow the bulb J and light kit to cool down before touching the bulb J or the light kit Note This fan uses three 60 watt max candelabra base bulbs J 4 5 Attach the pull chain extensions EE or cu...

Page 20: ...ATING INSTRUCTIONS 1 The pull chain labeled FAN has four positions to control fan speed One pull is HIGH two is MEDIUM three is LOW and four turns the fan OFF 1 2 The pull chain labeled LIGHT is used...

Page 21: ...re moving the re verse switch 3A In warmer weather push the reverse switch to the left to display a Sun icon which will result in downward airflow creating a wind chill effect 3B In cooler weather pus...

Page 22: ...ean the motor housing with only a soft brush or lint free cloth to avoid scratching the finish Clean the blades with a lint free cloth You may occasionally apply a light coat of furniture polish to wo...

Page 23: ...range dimmer switch to control the fan speed 4 Run the fan continuously for 24 48 hours on medium or high speed for a break in period 5 Ensure the outlet box is secured to the building structure 6 En...

Page 24: ...damage to any part such as by accident or misuse or improper installation or by affixing any accessories is not covered by this warranty The manufacturer assumes no responsibility whatsoever for fan i...

Page 25: ...Monday Thursday 8 a m 5 p m EST Friday PART DESCRIPTION MODEL 40198 PART MODEL 40199 PART A Downrod 179178 A 176493 A B Canopy 179178 B 176493 B C Mounting Bracket 179178 C 176493 C D Light Kit Fitte...

Page 26: ...tamento de Servicio al Cliente al 1 800 643 0067 de lunes a jueves de 8 a m a 6 p m hora est ndar del Este y los viernes de 8 a m a 5 p m hora est ndar del Este 26 ADJUNTE SU RECIBO AQU N mero de seri...

Page 27: ...es de ensamblaje 32 Instrucciones de montaje en ngulo y est ndar 34 Instrucciones de montaje cerrado 37 Cableado 38 Instalaci n final 41 Instalaci n del kit de iluminaci n 43 Instrucciones de funciona...

Page 28: ...CRIPCI N CANTIDAD A Varilla 1 B Base 1 C Abrazadera de montaje 1 D Soporte del kit de iluminaci n 1 E Ensamblaje del motor 1 F Cubierta de la horquilla 1 G Brazo del aspa 5 H Aspa 5 I Pantalla de vidr...

Page 29: ...amblado en la varilla A Cant 1 Sujetador de la varilla preensamblado en la varilla A Cant 1 Tornillo de ajuste de la carcasa del motor preensamblado en el ensamblaje del motor E Cant 2 Tornillo de mon...

Page 30: ...la velocidad del ventilador ADVERTENCIA para reducir el riesgo de incendios descargas el ctricas o lesiones personales instale el ventilador en una caja de salida marcada como ACCEPTABLE FOR FAN SUPP...

Page 31: ...de tener todas las piezas Compare todas las piezas con la lista del contenido del paquete y con la lista de aditamentos No intente ensamblar el producto si falta alguna pieza o si estas est n da adas...

Page 32: ...irse lesiones graves o la muerte 1 2 Determine los m todos de instalaci n que utilizar Nota La instalaci n de montaje al ras no est disponible para este art culo Importante Si realiza el montaje en ng...

Page 33: ...alar la abrazadera de montaje C ya que esta soportar el ventilador Importante Si realiza el montaje en ngulo aseg rese de que el extremo abierto de la abrazadera de montaje C est instalado en direcci...

Page 34: ...mayor altura Para techos m s altos se recomienda utilizar una varilla m s larga no incluida El montaje en ngulo es mejor para los techos en ngulo o de b veda En ocasiones es necesaria una varilla m s...

Page 35: ...mblaje del motor E Aditamentos utilizados FF Pasador de la varilla x 1 GG Sujetador de la varilla x 1 HH Tornillo de ajuste de la carcasa del motor x 2 F GG HH FF E A 3 4 Seg n el largo de la varilla...

Page 36: ...onde y verde Importante Si no cort los cables conductores en el paso 4 el paso 5 no es necesario y puede continuar con el paso 6 en su lugar 5 6 Instale el extremo con la bola de la varilla A en la ab...

Page 37: ...rta de la base no se utilizan en este tipo de instalaci n 1 K B 2 Alinee la base B con los orificios de la parte superior del ensamblaje del motor E Fije la base B a la parte superior del ensamblaje d...

Page 38: ...termine el esquema de cableado adecuado PRECAUCI N aseg rese de que la caja de salida cuente con la puesta a tierra adecuada o de que haya un cable verde o desnudo de tierra De las tres opciones que s...

Page 39: ...ENTILADOR Y LUZ CONTROLADOS POR DOS INTERRUPTORES DE PARED para controlar el ventilador y la luz con interruptores de pared separados conecte el cable negro del ventilador al cable negro del interrupt...

Page 40: ...a hacia arriba y empuje suavemente los cables y los conectores de cables DD hacia dentro de la caja de salida ADVERTENCIA aseg rese de que no haya conductores desnudos ni filamentos de cables visibles...

Page 41: ...te de montaje JJ y g relos en direcci n de las manecillas del reloj Aditamentos utilizados JJ Tornillo de la abrazadera de montaje x 4 B JJ 1 C 2 Asegure la base B con los tornillos del soporte de mon...

Page 42: ...as aspas H y los brazos del aspa G restantes Aditamentos utilizados BB Tornillo del aspa x 15 CC Arandela del aspa x 15 BB H G CC H 3 4 Alinee el brazo del aspa G y el aislador de aspa II con dos orif...

Page 43: ...de ambos enchufes Aseg rese de que los enchufes est n firmemente conectados Aditamentos utilizados KK Tornillo de la placa x 3 D E 1 KK E 2 Alinee los orificios del soporte del kit de iluminaci n D c...

Page 44: ...luminaci n se enfr en antes de tocar la bombilla J o el kit de iluminaci n Nota Este ventilador usa tres bombillas de base candelabro de 60 vatios como m ximo J 4 5 Conecte las extensiones para la cad...

Page 45: ...OR tiene cuatro posiciones para controlar la velocidad del ventilador Jale una vez para la posici n HIGH ALTA dos para la posici n MEDIUM MEDIA tres para la posici n LOW BAJA y cuatro para la posici n...

Page 46: ...de reversa 3A En climas m s c lidos presione el interruptor de reversa hacia la izquierda y ver un icono de un sol lo que crear un flujo de aire descendente que generar un efecto de viento refrescant...

Page 47: ...lo con un cepillo suave o un pa o sin pelusas para evitar rayar el acabado Limpie las aspas con un pa o sin pelusas De vez en cuando puede aplicar una fina capa de pulidor para muebles en las aspas de...

Page 48: ...completo para controlar la velocidad del ventilador 4 Haga funcionar el ventilador de 24 a 48 horas continuamente a velocidad media o alta durante el per odo de asentamiento 5 Revise que la caja de sa...

Page 49: ...bilidad Esta garant a no se aplica a ning n da o que se produzca en cualquier pieza del producto como consecuencia de un accidente uso indebido o instalaci n incorrecta o causado por elementos accesor...

Page 50: ...y los viernes de 8 a m a 5 p m hora est ndar del Este PIEZA DESCRIPCI N MODELO 40198 PIEZA MODELO 40199 PIEZA A Varilla 179178 A 176493 A B Base 179178 B 176493 B C Abrazadera de montaje 179178 C 1764...

Reviews: