17
CARE AND MAINTENANCE
At least twice each year, lower the canopy to check the downrod assembly, and then tighten all
screws on the fan. Clean the motor housing with only a soft brush or lint-free cloth to avoid scratching
the finish. Clean the blades with a lint-free cloth.
Total fixture wattage is 16 watts; do not attempt to replace LED.
Battery Replacement:
Use a A23, 12-volt alkaline battery. Exhausted batteries should be removed
from remote. Non-rechargeable batteries should not be recharged. Do not dispose of batteries in fire,
as they may explode or leak.
Important:
Shut off the main power supply before you begin any maintenance tasks. Do not use
water or a damp cloth to clean the ceiling fan.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The fan does not
move.
1. The reverse switch is not engaged.
2.
The wall switch is turned off.
3.
The power is off or the fuse
(breaker) is blown.
4. There is a faulty wire connection.
1. Firmly push the reverse switch
completely left or right.
2. Make sure the wall switch is turned
on.
3. Turn the power on or check the
fuse (breaker).
4.
Turn the power off and check all
connections at the ceiling outlet
box.
The fan operates
correctly, but the
lights are not
working.
1. The light kit wire plugs are not
connected properly.
2. There is a faulty wire connection.
1. Ensure the 6-pin connectors in the
light kit are connected properly.
2.
Turn the power off and check all
connections at the ceiling outlet
box.
The fan is noisy.
1. The blades are loose.
2. There is a cracked blade.
3. The wall control is not compatible
with the fan.
4. The outlet box is not secure.
5. The mounting bracket is not
secure.
1. Check and tighten all screws that
hold the fan blades to the blade
arms and the motor.
2. Replace the cracked blade.
3. Do not use a full range dimmer
switch to control the fan speed.
4. Ensure the outlet box is secured
to the building structure.
5. Ensure the mounting bracket is
secured to the outlet box and that
the screws are tight.