If you decided to cut back the lead wires in Step 4,
strip a 1/2 in. of insulation from end of white wire.
Twist stripped ends of each strand of wire within
the insulation with pliers. Repeat Step 5 for black,
blue (if applicable) and green wires.
5
5.
FAN MOUNTING
Install ball end of downrod (A) into mounting
bracket (C) opening. Align slot in ball with tab in
mounting bracket (C).
DANGER:
Failure to align slot in ball with tab
may result in serious injury or death.
6.
WARNING:
To reduce the risk of fire, electrical
shock, or personal injury, wire connectors provided with
this fan are designed to accept only one 12-gauge
house wire and two lead wires from the fan. If your
house wire is larger than 12-gauge or there is more
than one house wire to connect to the corresponding
fan lead wires, consult an electrician for the proper size
wire connectors to use.
CAUTION:
Be sure outlet box is properly grounded
and that a ground (green or bare) wire is present.
WARNING:
If house wires are different colors than
referred to in the following steps, stop immediately. A
professional electrician is recommended to determine
wiring.
WIRING
6
Hanging
Ball Slot
Tab
9
Lowes.com/harborbreeze
B
C
A