6

Lowes.com/harborbreeze

SAFETY INFORMATION

CAUTION:

 Read all instructions and safety information before installing your new fan. Review the 

accompanying assembly diagrams.

CAUTION:

 Be sure the outlet box is properly grounded or that a ground (green or bare) wire is present.

CAUTION:

 Carefully check all screws, bolts, and nuts on the fan motor assembly to ensure they are 

secured.

PREPARATION

Before beginning the assembly of this product, ensure all parts are present. Compare all parts with 

the package contents list and hardware contents list. If any part is missing or damaged, do not 

attempt to assemble the product.
After opening the top of the carton, remove the mounting hardware package from the foam inserts, 

then remove the motor from the packaging and place it on a soft surface, such as a carpet, to avoid 

damage to the finish.

Estimated Assembly Time:

 120 minutes

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety 

Glasses, Step Ladder, Wire Strippers and Wire Cutters
Helpful Tools (not included): AC Tester Light, Tape Measure, Wiring Handbook

Summary of Contents for 40945

Page 1: ... Thursday 8 a m 5 p m EST Friday 1 ATTACH YOUR RECEIPT HERE Serial Number _________________________ Purchase Date _________________________ Lowes com harborbreeze Harbor Breeze is a registered trademark of LF LLC All Rights Reserved EB15488 ITEM 0451809 PACIFIC GROVE CEILING FAN MODEL 40945 Español p 20 H arbor Bree z e LISTED FOR WET LOCATION ...

Page 2: ... Safety Information 5 Preparation 6 Initial Installation 7 Standard or Angle Mounting Instructions 9 Closemount Instructions 11 Wiring 12 Final Installation 13 Operating Instructions 16 Care and Maintenance 17 Troubleshooting 17 Limited Lifetime Warranty 18 Replacement Parts List 19 ...

Page 3: ...sembled to the Motor Assembly H 1 J Fitter Plate 1 K Switch Housing 1 L Blade Arm 5 M Blade 5 N Motor Screw preassembled to the Motor Assembly H 10 1 extra O Mounting Bracket Screw preassembled to the Mounting Bracket D 4 P Fitter Plate Screw preassembled to the Adapter Plate I 3 Q Set Screw preassembled to the Motor Assembly H 2 R Phillips head Closemount Screw preassembled to Motor Assembly H 3 ...

Page 4: ...borbreeze HARDWARE CONTENTS shown actual size Wire Connector Qty 3 1 extra Pull Chain Extension Qty 1 Blade Screw Qty 15 1 extra Rubber Washer Qty 15 1 extra Blade Washer Qty 15 1 extra AA BB CC DD EE H arbor Bree z e ...

Page 5: ...ecessary while handling fan parts with sharp edges WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked ACCEPTABLE FOR FAN SUPPORT and use the mounting screws provided with the outlet box Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electr...

Page 6: ... all parts are present Compare all parts with the package contents list and hardware contents list If any part is missing or damaged do not attempt to assemble the product After opening the top of the carton remove the mounting hardware package from the foam inserts then remove the motor from the packaging and place it on a soft surface such as a carpet to avoid damage to the finish Estimated Asse...

Page 7: ...tely Angle mounting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance Important If using the angle mount check to ensure the ceiling angle is not steeper than 16 Closemount installation is more suitable for ceilings lower than 8 ft high Flushmount installation is not available for this item 2 Downrod Mounting Flushmount Closemoun...

Page 8: ... to use the proper hardware when installing the mounting bracket D as this will support the fan Important If using the angle mount ensure the open end of the mounting bracket D is installed facing the higher point of the ceiling 6 Remove all 10 preassembled motor screws N and five preassembled plastic motor blocks from the underside of the motor assembly H Discard the motor blocks but keep the mot...

Page 9: ... the yoke at the top of the motor assembly H 2 Insert the downrod A through the canopy E and yoke cover G Feed the wires from the motor assembly H through the downrod A 3 Slide the downrod A into the yoke of the motor assembly H align the holes then re install the downrod clip C and downrod pin B Secure with set screws Q 1 2 A G E H 3 A B C H Q G H Q A B C Yoke Yoke Yoke ...

Page 10: ...insulation from the end of the white wire Twist the stripped ends of each strand of wire within the insulation with pliers not included Repeat this step for black blue and green wires Note If you did not cut back the lead wires in Step 4 Step 5 is not necessary and you may proceed to Step 6 6 Install the ball end of the downrod A into the opening of mounting bracket D Align one of the four slots i...

Page 11: ...t used in this type of installation 2 Remove three Phillips head closemount screws R from the top of the motor assembly H Align the canopy E with the holes in the top of the motor assembly H then re install the Phillips head closemount screws R to secure the canopy E to the top of the motor assembly H 3 Raise the fan and place the canopy E on the hook on the mounting bracket D temporarily leaving ...

Page 12: ...s to connect Connect the White wire from the fan to the White supply wire Connect the Black and Blue wires from the fan to the Black supply wire Secure all wiring connections together with wire connectors AA Note The Black wire is hot power for the fan The White wire is common The Blue wire is hot power for light sold separately wiring instructions will differ if optional light kit is purchased Re...

Page 13: ...ghten all mounting bracket screws O securely 3 Partially insert the blade screws CC along with the rubber washers DD and blade washers EE through the blade M and into the blade arm L Tighten each blade screw CC with a Phillips screwdriver not included starting with the one in the middle Repeat this step for the remaining blades M and blade arms L Hardware Used CC Blade Screw x 15 Rubber Washer x 1...

Page 14: ... assembly H loosen do not remove the other two screws Insert the 9 pin connector from the motor assembly H through the hole in the fitter plate J 6 Attach the fitter plate J to the adapter plate by twisting the fitter plate J until the loosened fitter plate screws P engage the key slots on the fitter plate J Re install the third fitter plate screw P into the closed hole in the fitter plate J and s...

Page 15: ... H to the 9 pin connector from the switch housing K and ensure the connections are secure 8 Secure the switch housing K to the fitter plate J using the previously removed switch housing screws S 9 Attach the pull chain extension BB or custom pull chain extension not included to the fan pull chain Hardware Used BB Pull Chain Extension x 1 7 H K I 8 J BB K S 9 H arbor Bree z e ...

Page 16: ...ut feeling a difference in your comfort Note Wait for the fan to stop before moving the reverse switch 2a In warmer weather push the reverse switch left which will result in downward airflow creating a wind chill effect 2b In cooler weather push the reverse switch right which will result in upward airflow that can help move stagnant hot air off the ceiling area Important The reverse switch must be...

Page 17: ...le with the fan 4 The outlet box is not secure 5 The mounting bracket is not secure 1 Check and tighten all screws that hold the fan blades to the blade arms and the motor 2 Replace the cracked blade 3 Do not use a full range dimmer switch to control the fan speed 4 Ensure the outlet box is secured to the building structure 5 Ensure the mounting bracket is secured to the outlet box and that the sc...

Page 18: ...lid Due to varying climate conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions Any glass provided with this fan is not covered by the warranty Any replacement of defective parts from the ceiling fan must be reported with...

Page 19: ... PARTS LIST For replacement parts call the customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday PART DESCRIPTION PART A Downrod 0451809 A D Mounting Bracket 0451809 D E Canopy 0451809 E L Blade Arm 0451809 L M Blade 0451809 M HW Hardware Bag 0451809 HW A D E L M HW 9031 101915 ...

Reviews: