19
Lowes.com/harborbreeze
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
There is excessive
wobbling.
1. The blades and/or blade are
loose.
2. The blades are unbalanced.
3. The fan mounting is not
secure.
4. The fan is too close to the
vaulted ceiling.
5. The set screw on the motor
housing yoke is loose.
1. Check and tighten all screws that hold
the fan blades to the blade arms and
the blade arms to the motor.
2. Switch one blade with a blade from
the opposite side. Or balance the fan
using a balancing kit (not supplied).
3. Turn off the power. Loosen the
canopy and verify that the mounting
bracket is secure to the electrical
outlet box. The bracket must be
flush without movement against the
outlet box.
4. Use a longer downrod or move the
fan to another location.
5. Lift up the yoke cover and tighten the
set screw to the yoke until secure.
The fan operates
correctly, but the
lights are not
working.
1. The bulbs are not installed
correctly.
2. The light kit wire-pin
connnectors are not
connected properly.
3. There is a faulty wire
connection.
4. The total power of the light is
exceeding 190W.
1. Re-install the bulb(s).
2. Ensure the wire-pin connectors in the
light kit fitter are connected properly.
3. Turn the power off and check all
connections at the ceiling outlet box.
4. The fan comes with a 190W limiter.
When the total watts of the lights is
over 190W, the lights do not work.
Please replace the bulbs with lower
wattage bulbs.