CLOSEMOUNT STYLE FAN MOUNTING

4.  Align mounting holes on canopy (B) with 

holes on motor housing assembly (H) and 

fasten using three previously removed 

screws. Securely tighten screws.

5.  Hang the fan on the hook on the mounting 

bracket (A) using one of the non-slotted holes 

in the canopy (B).

JJ

H

B

4

B

A

Hook

5

WIRING

2.  Tape the wire connectors (AA) and wires 

together. The wires should be spread apart with 

the grounded conductor and the equipment-

grounding conductor on one side of the outlet 

box and the ungrounded conductor on the other 

side of the outlet box. Be sure no bare wire or 

wire strands are visible after making connection. 

Place green and white connections on opposite 

side of box from the black and blue connections. 

The splices should be turned upward and 

pushed carefully up into the outlet box.

AA

2

Hardware Used

Wire Connector

x 4

AA

WIRING

1.  Connect the 

BLACK

 and 

BLUE

 wires from 

the fan to the house 

BLACK

 wire. Connect 

the 

WHITE

 wire from fan to the house 

WHITE

 wire.  Connect all 

GROUNDED 

(GREEN)

 wires together from fan to the 

house 

GREEN/GROUND

 wire.

NOTE:

 

BLACK

 wire is hot power for 

fan. 

BLUE

 wire is hot power for light kit. 

WHITE

 wire is common for fan and light kit. 

GREEN

 wire is ground wire. If house wires 

are different colors than referred to above, 

stop immediately. Consult a licensed 

electrician to determine proper wiring.

Grounded/Green

Black

White

Grounded/

  Green

Black

Blue

White

outlet box

blue black white green

white

GREEN/

black

Supply circuit

speed

switch 

GROUNDED

1

11

10

1.  Directly align the locking slots of the canopy 

(B) with the preassembled screws in the 

mounting bracket (A). Push up to engage the 

slots, then turn clockwise to lock in place. 

Immediately tighten the two screws firmly. 

Install the non-slotted screws previously 

removed (Step 3, page 6) to canopy (B) and 

tighten securely.

Outlet box

Screws

B

1

FINAL INSTALLATION

If you chose “Downrod-Style Mounting,” 

continue to Step 1. Proceed to Steps 2-3 if 

you chose “Closemount-Style Mounting.”

2.  Remove the fan from the hook on the 

mounting bracket (A). Align the locking slots 

of the canopy (B) with the two screws in the 

mounting bracket (A). Push up to engage the 

slots, then turn clockwise to lock in place. 

Immediately tighten two screws firmly.

Outlet box

Screws

Hook

Locking

slots 

A

B

2

Proceed to Step 4.

Summary of Contents for 00891

Page 1: ...rbor Breeze is a registered trademark of LF LLC All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday PH18483 ATTACH YOUR RECEIPT HERE UL MODEL LRN32 ...

Page 2: ...st 19 3 2 PACKAGE CONTENTS PART DESCRIPTION QUANTITY A Mounting Bracket preassembled to canopy B 1 B Canopy 1 C Canopy Cover preassembled to canopy B 1 D Yoke Cover 1 E Downrod 1 F Blade Bracket 4 G Blade 4 H Motor Housing Assembly 1 I Switch Housing 1 J Light Kit preassembled to switch housing I 1 K Glass Bowl 1 L Bulb 2 M Bowl Cap preassembled to light kit J 1 N Finial preassembled to light kit ...

Page 3: ...re the electricity has been turned off at the circuit breaker or fuse box before beginning installation PERSONAL INJURY HAZARD To reduce the risk of injury to persons install fan so the blades are 7 ft above the floor FIRE ELECTRIC SHOCK OR PERSONAL INJURY HAZARD To reduce the risk of fire electric shock or personal injury mount to an outlet box marked ACCEPTABLE FOR FAN SUPPORT OF 35 lbs OR LESS ...

Page 4: ...ket A to the outlet box not included sliding the mounting bracket A over the two outlet box screws not included Securely tighten the two outlet box screws IMPORTANT If using the angle mount make sure open end of mounting bracket A is installed facing the ceiling A B 1 A Outlet box 4 E clip pin 1 E D C B 2 O H 2 Loosen but do not remove Remove and save A B 3 INITIAL INSTRUCTIONS DOWNROD STYLE FAN M...

Page 5: ...areful when aligning the tab to the slot If not fully engaged there is a possibility of fan falling which may result in serious injury or death CLOSEMOUNT STYLE FAN MOUNTING 1 Remove the canopy cover C from the bottom of the canopy B 2 Remove three of the six screws and lock washers every other one securing the motor collar to the top of the motor housing assembly H 3 Place rubber gasket GG over r...

Page 6: ...e house GREEN GROUND wire NOTE BLACK wire is hot power for fan BLUE wire is hot power for light kit WHITE wire is common for fan and light kit GREEN wire is ground wire If house wires are different colors than referred to above stop immediately Consult a licensed electrician to determine proper wiring Grounded Green Black White Grounded Green Black Blue White outlet box blue black white green whit...

Page 7: ...with Washer x 8 FF 6 Remove the preassembled screws from the switch housing cover on motor housing assembly H 7 If you want to use the light kit J connect the male plug from the motor housing assembly H to the female plug from the switch housing I Screw Switch housing cover H 6 Female plug I J Male plug H 7 If using fan WITH the light kit continue to Step 7 If using fan WITHOUT the light kit proce...

Page 8: ...le are recommended for this step K 11 12 Place previously removed rubber washer and hex nut Step 10 page 14 onto the pipe and securely tighten Pass fan pull chain through side hole on bowl cap M then place bowl cap M and finial N over pipe and securely tighten 13 Attach fan pull chain extension BB and light kit pull chain extension CC to corresponding chains Assembly is now complete Rubber washer ...

Page 9: ... to stop before reversing switch A In warmer weather counterclockwise rotation creates downward airflow which cools the air Push the switch LEFT and see a Sun icon B In cooler weather clockwise rotation creates an upward airflow which moves hot air from the ceiling into the room Push the switch RIGHT and see a Snowflake icon 17 16 Hardware Used Plastic Plug x 8 DD 16 Attach switch housing I to swi...

Page 10: ...anty which can not be disclaimed is limited to the lifetime limited period as specified in our warranty The manufacturer shall not be liable for incidental consequential or special damages arising at or in connection with product use or performance except as may otherwise be accorded by law This warranty gives you specific legal rights an you also have other rights which may vary from state to sta...

Page 11: ...a de LF LLC Todos los derechos reservados Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 800 643 0067 de lunes a jueves de 8 a m a 6 p m hora estándar del Este o los viernes de 8 a m a 5 p m hora estándar del Este ADJUNTE SU RECIBO AQUÍ MODELO UL LRN32 ...

Page 12: ...IÓN CANTIDAD A Abrazadera de montaje preensamblado a la base B 1 B Base 1 C Cubierta de la base preensamblado a la base B 1 D Cubierta de la horquilla 1 E Varilla 1 F Abrazadera de aspa 4 G Aspa 4 H Ensamble de carcasa del motor 1 I Carcasa del interruptor 1 J Kit de iluminación preensamblado en la carcasa del interruptor I 1 K Pantalla de vidrio 1 L Bombilla 2 M Tapa de la pantalla preensamblado ...

Page 13: ...antes de comenzar la instalación RIESGO DE LESIÓN PERSONAL Para reducir el riesgo de lesiones a personas instale el ventilador de forma que el aspa esté a por lo menos 2 1 m sobre el piso RIESGO DE INCENDIOS DESCARGAS ELÉCTRICAS Y LESIONES PERSONALES Para reducir el riesgo de incendios descargas eléctricas o lesiones personales monte en una caja de salida marcada ACCEPTABLE FOR FAN SUPPORT OF 15 9...

Page 14: ...eslizando la abrazadera de montaje A por los dos tornillos de la caja de salida no se incluyen Apriete firmemente los dos tornillos de la caja de salida IMPORTANTE Si realiza el montaje en ángulo asegúrese de que el extremo abierto de la abrazadera de montaje A esté instalado en dirección hacia el techo A B 1 A Caja de salidad 4 E Sujetador Pasador 1 E D C B 2 O H 2 Suelte pero no retire Retire y ...

Page 15: ...CIA Tenga cuidado al alinear la lengüeta con la ranura Si no calza bien es posible que el ventilador se caiga lo que podría provocar lesiones graves o la muerte MONTAJE EN ESTILO DE MONTAJE CERRADO 1 Retire cubierta de la base C de la parte inferior de la base B 2 Retire tres de los seis tornillos y arandelas de seguridad uno por medio fijando el collar del motor a la parte superior de la carcasa ...

Page 16: ...ntación eléctrica al kit de iluminación El conductor blanco es el cable común para el ventilador y el kit de iluminación El cable verde tiene conexión a tierra Si los cables de la caja no tienen los mismos colores que se mencionaron deténgase de inmediato Recomendamos que un electricista profesional determine el cableado adecuado Verde de puesta a tierra Negro Blanco Verde de puesta a tierra Negro...

Page 17: ...ire los tornillos preensamblados de la cubierta de la carcasa del interruptor en el ensamble de la carcasa del motor H 7 Si desea usar el kit de iluminación J conecte el enchufe macho del ensamble de la carcasa del motor H al enchufe hembra de la carcasa del interruptor I Tornillo Cubierta de la carcasa del interruptor H 6 Enchufe hembra I J Enchufe macho H 7 Si usa un ventilador CON el kit de ilu...

Page 18: ...cen este paso K 11 12 Coloque la arandela de goma y la tuerca hexagonal que retiró con anterioridad paso 10 página 32 en el tubo y apriete con firmeza Pase la cadena del tirador a traves del orificio lateral en la tapa de la pantalla M luego coloque la tapa de la pantalla M y el remate N sobre el tubo y apriete con firmeza 13 Conecte la extensión de la cadena del tirador del ventilador BB y la ext...

Page 19: ...del reloj crea un flujo de aire descendente que refresca el ambiente Mueva el interruptor a la IZQUIERDA y verá un icono de sol B En épocas más frías la rotación en dirección de las manecillas del reloj crea un flujo de aire ascendente que mueve el aire caliente desde el techo hacia la parte central de la habitacion Mueva el interruptor a la DERECHA y vera un icono de copo de nieve 36 35 Aditament...

Page 20: ...nciales resultantes o especiales que surjan en relación con el uso o el funcionamiento del producto excepto que la ley indique lo contrario Esta garantia le otorga derechos legales especificos y usted tiene tambien otros derechos que varían según el estado Esta garantía sustituye cualquier garantía previa NOTA Es normal que el ventilador se tambalee un poco por lo cual no se debe considerar como u...

Reviews: