background image

2

Table of Contents ................................................................ 2

Safety Information ............................................................... 2

Warranty ............................................................................... 3

Pre-Installation .................................................................... 3

Installation ............................................................................ 6

Assembly .............................................................................. 7

Operation ........................................................................... 14

Care and Cleaning ............................................................. 15

Troubleshooting ................................................................. 15

1. 

To reduce the risk of electric shock, ensure the electricity has 
been turned off at the circuit breaker or fuse box before you 
begin.

2. 

All wiring must be in accordance with the National Electrical 
Code ANSI/NFPA 70-1999 and local electrical codes. Electrical 
installation should be performed by a qualified licensed 
electrician.

3. 

The outlet box and support structure must be securely mounted 
and capable of reliably supporting 35 lbs. (15.9 kg). Use only UL 
Listed outlet boxes marked “Acceptable for Fan Support of 35 lbs. 
(15.9 kg) or less.”

4. 

The fan must be mounted with a minimum of 7 ft. (2.1 m) clearance 
from the trailing edge of the blades to the floor.

5. 

Do not operate the reversing switch while the fan blades are in 
motion. You must turn the fan off and stop the blades before you 
reverse the blade direction.

6. 

Do not place objects in the path of the blades.

7. 

To avoid personal injury or damage to the fan and other items, 
use caution when working around or cleaning the fan.

8. 

Electrical diagrams are for reference only. Light kits that are not 
packed with the fan must be UL-listed and marked suitable for 
use with the model fan you are installing. Switches must be UL 
General Use Switches. Refer to the instructions packaged with 
the light kits and switches for proper assembly.

9. 

After making electrical connections, spliced conductors should be 
turned upward and pushed carefully up into the outlet box. The 
wires should be spread apart with the grounded conductor and 
the equipment-grounding conductor on one side of the outlet box.

10. 

All setscrews must be checked and retightened where 
necessary before installation.

WARNING:

 To reduce the risk of personal injury, do not 

bend the blade brackets (also referred to as flanges) during 

assembly or after installation. Do not insert objects in the 

path of the blades.

WARNING:

 Remove the rubber motor stops on the bottom of 

the fan before installing the blades or testing the motor.

WARNING:

 To reduce the risk of fire or electric shock, do 

not use this fan with any solid-state speed control device.

WARNING:

 To avoid possible electrical shock, turn the 

electricity off at the main fuse box before wiring. If you 

feel you do not have enough electrical wiring knowledge or 

experience, contact a licensed electrician.

WARNING:

 Electrical diagrams are for reference only. 

Optional use of any light kit shall be UL-listed and marked 

suitable for use with this fan.

WARNING:

 To reduce the risk of fire, electric shock, or 

personal injury, mount to outlet box marked “Acceptable 

for fan support of 35 lbs. (15.9 kg) or less,” and use the 

screws provided with the outlet box.

Safety Information

Table of Contents

READ AND SAVE THESE INSTRUCTIONS

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation.      

Summary of Contents for 1002 263 777

Page 1: ... 11 Do not drop or bump the unit 12 After making the electrical connections secure each with electrical tape spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box NOTE The ceiling fan must be set at HIGH speed and light kit if installed s...

Page 2: ...y through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay To view an instructional video on how to install this product 1 Go to www homedepot com and enter either the Item or Model number found in the top right...

Page 3: ...ling the blades or testing the motor WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device WARNING To avoid possible electrical shock turn the electricity off at the main fuse box before wiring If you feel you do not have enough electrical wiring knowledge or experience contact a licensed electrician WARNING Electrical diagrams are for r...

Page 4: ...er the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow a limitatio...

Page 5: ... 1 CC Locking pin 1 Part Description Quantity DD Extra blade bracket screw 1 EE Plastic plug to be used for fan without light kit 1 FF Wire connecting nut 3 Pre Installation continued HARDWARE INCLUDED NOTE Hardware not shown to actual size AA BB CC DD EE FF ...

Page 6: ...embly 1 E Light kit fitter assembly 1 Part Description Quantity F Blade 5 G Blade bracket with pre installed screws 5 H Glass bowl 1 I LED bulbs 9 5 Watt Max 3 IMPORTANT This product and or components are governed by one or more of the following U S Patents 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 and other patents pending Pre Installation continued PACKAGE CONTENTS A B C F D I E G H ...

Page 7: ...the appropriate fasteners and materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 lbs Do not use a plastic outlet box The illustrations below show three different ways to mount the outlet box If the canopy C touches the ball downrod assembly B then remove the decorative canopy bottom cover and turn the canopy C 180 before attaching the ca...

Page 8: ... until it snaps into its locked position Re tighten the setscrews II on the collar on top of the fan motor assembly D Remove the canopy bottom cover HH from the canopy C by turning the bottom cover counter clockwise until it unlocks Loosen the two canopy screws GG located in the bottom of the mounting bracket and turn the canopy counter clockwise to remove the mounting bracket A from the canopy C ...

Page 9: ...curely tighten the two mounting screws JJ 1 WARNING To reduce the risk of fire electric shock or personal injury mount to an outlet box marked Acceptable for fan support of 35 lbs 15 9 kg or less and use the screws provided with the outlet box Hanging the fan 2 Carefully lift the fan motor assembly D up to the slide on mounting bracket A Insert the ball portion of the ball downrod assembly into th...

Page 10: ...ire and two wires from the fan If you have larger than 12 gauge house wiring or more than one house wire to connect to the fan wiring consult an electrician for the proper size wire nuts to use Please refer to remote installation instructions at the beginning of this document NOTE The fan comes with 54 in lead wires for use with an extended ball downrod assembly If using the 4 5 in ball downrod as...

Page 11: ...ing bracket A Push up the canopy C and turn clockwise until the alignment post QQ engages the round hole and the screws GG engage to the key slots Firmly tighten the two mounting screws GG Install the decorative bottom cover HH by aligning the covers slots with screws in the bottom of the canopy C Rotate the bottom cover clockwise to lock in place WARNING When using the standard ball downrod mount...

Page 12: ...he blades to the blade brackets 2 Mount the fan blade F to the blade bracket G by aligning the three key slot holes in the blade F with the three posts on the top of the blade bracket G Hold the blade F with both hands close to the blade bracket G down firmly Ensure the key slot holes are properly seated on the blade bracket G posts While still holding the blade F down with both hands firmly slide...

Page 13: ...ght kit mounting screws MM on the black bracket below the fan motor assembly D Connect the wires from the light kit fitter assembly E to the wires from the fan motor assembly D by connecting the molded adaptor plugs together Carefully tuck all wires and splices into the switch cup Align the three holes in the black bracket below fan motor assembly D with the three holes in the switch cup of the li...

Page 14: ...y removing the center hex nut NN inside the switch cup WW and then thread the switch cup WW off the threaded nipple on the top of the light kit fitter assembly E Press the plastic plug EE provided into the center hole of the switch cup WW Connect the quick connect couplers The fan will not start without this connection Position the switch cup WW onto the black bracket and reinstall the light kit m...

Page 15: ...ction of the blades forward switch left or reverse switch right A Warm weather Forward A downward airflow creates a cooling effect This allows you to set your air conditioner on a higher setting without affecting your comfort B Cool weather Reverse An upward airflow moves warm air off of the ceiling This allows you to set your heating unit on a lower setting without affecting your comfort NOTE Wai...

Page 16: ...n the ceiling above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceiling Measure this distance Rotate the fan until the next blade is positioned for measurement Repeat for each blade Any measurement deviation should be within 1 8 in Run the fan for ten minutes If the fan continues to wobble please contact Customer Service and a balancing kit wil...

Page 17: ...ns problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for future use ...

Reviews: