background image

110 V AC, 220 V AC, 380 V AC, 440 V AC, 60Hz

(But, 25 A of TPR-2 are only available 110 V and

220 V)

25 A, 35 A, 50 A, 70 A, 100 A, 150 A, 200 A

0 ~ 50 

(humidity below 90 %)

Above 100 A protected by high - speed breaking

fuse

Resistive Load

Current Input : 4 ~ 20 mA DC, Voltage 

Input : 1 ~ 5 V DC

Contact Input : ON-OFF

Above 97 % of input voltage 

Natural Cooling, forced cooling by fan for above

100 A

Above 200 

(500 V mega)

Aspect Dimension

[Unit :   mm]

Before you use, read safety precautions carefully, and use this product properly.
The precautions described in this manual contain important contents related with
safety; therefore, please follow the instructions accordingly. The precautions are
composed of DANGER, WARNING and CAUTION.

There is a danger of occurring electric shock in the input/output terminals so
please never let your body or conductive substance is touched.

1. If this product is used with the machinery which may be caused human injury

or serious property damage then use it after surely installing the protection
equipment for two or three times.

2. To prevent defection or malfunction of this product, apply a proper power

voltage in accordance with the rating.

3. To prevent electric shock or malfunction of product, do not supply the power

until the wiring is completed.

4. Do not decompose, modify, revise or repair this product. This may be a cause

of malfunction, electric shock or fire.

5. Reassemble this product while the power is OFF. Otherwise, it may be a

cause of malfunction or electric shock.

6. If you use the product with methods other than specified by the manufacturer,

there may be bodily injuries or property damages.

7. There is a possibility of occurring electric shock so please use this product

after installing it onto a panel while it is operating.

1. The place of operating this product affect to the its functions and life cycle so

that avoid to use it in the following circumstance.
A place of having high humidity and not circulating air
A place of piling up dust or impurity or having high ambient temperature or
high vibration

2. The contents of this manual may be changed without prior notification.
3. Before using the product you purchased, make sure that it is exactly what you

ordered.

4. Make sure that there is no damage or abnormality of the product during the

delivery.

5. After turning OFF power sources of all instruments, please wire them.
6. The Thyristor Power Regulator should be installed perpendicularly.
7. Install exhausting fan in internal and upside of the panel.
8. Tighten BOLT of the input and output wire enough.
9. Distribute the load equally.

10. Do not use this product at any place with corrosive (especially noxious gas or

ammonia) or flammable gas.

11. Do not use this product at any place with direct vibration or impact.
12. Do not use this product at any place with liquid, oil, medical substances, dust,

salt or iron contents. (Use at Pollution level 1 or 2)

13. Do not polish this product with substances such as alcohol or benzene. (Use

neutral detergent.)

14. Do not use this product at any place with a large inductive difficulty or

occurring static electricity or magnetic noise.

15. Do not use this product at any place with possible thermal accumulation due

to direct sunlight or heat radiation.

16. Install this product at place under 2,000 m in altitude.
17. When the product gets wet, the inspection is essential because there is

danger of an electric leakage or fire.

18. Do not connect anything to the unused terminals.
19. After checking the polarity of terminal, connect wires at the correct position.
20. For the continuous and safe use of this product, the periodical maintenance is

recommended.

21. Some parts of this product have limited life span, and others are changed by

their usage.

22. The warranty period for this product including parts is one year if this product

is properly used.

How to Operate
When installing the unit, the input and output terminals should be attached in
the direction of facing downward perpendicularly for the natural cooling.
Make sure that install high-speed breaking fuse between terminal R and power
source.
By the internal volume, the output voltage can be limited. (Only if the external
volume is not connected)
When the output voltage limitation setting is externally used, connect the
external volume (B 10 

1 W) to VR1, VR2, VR3 terminals. At this time, make

sure that the internal volume should be set at max (INC side).
When using without the external signal (when a temperature controller is not
used), please connect ref terminal and C1 (+) terminal.

Safety information

WARNING

CAUTION

DANGER

Power Supply

Rated Current 

Ambient temperature

Protection Circuit

Applied Load

Control Input

Output Voltage 

Cooling Method

Insulation

Resistance

Ratings

HEAD OFFICE 

1381-3, Juan-Dong, Nam-Gu Incheon, Korea

TEL: (82-32)876-4697  FAX : (82-32)876-4696

MAIN PRODUCTS
- DIGITAL : Temperature Controller, Counter, Timer,Speedmeter, 

Tachometer, Panel Meter, Recorder

- SENSOR : Proximity Sensor/Photo Electric Sensor, 

Rotary Encoder, Optical Fiber Sensor,   
Pressure Sensor

- ANALOG : Timer, Temperature Controller

Thyristor Power Regulator

TPR-2

We appreciate you for purchasing HanYoung NUX Co.,Ltd
product. Before using the product you have purchased,
check to make sure that it is exactly what you ordered. Then,
please use it following the instructions below.

INSTRUCTION MANUAL

Model and Suffix code

Capacity

H

W

D

25 A

35 A, 50 A, 70 A

100 A, 150 A, 200 A

Dimension

130

190

305

86

126

165

63

116

170

MB0101E050907

Single Phase

Phase 

Control

110 V

220 V

380 V

440 V

25 A

35 A

50 A

70 A

100 A

150 A

200 A

4 ~ 20 mA

Resistive Load

Model Name

Suffix Code

Description

2

P

TPR-

Phase 

Control Method

Power Supply 

(AC 60 Hz)

25A of TPR-2 are

only available 110 V
and 220 V.

Rated Current

Input Method

Load Characteristic

110

220

380

440

25

35

50

70

100

150

200

M

R