HANYOUNG NUX MP3-4 H Series Instruction Manual Download Page 4

3

4

Measurement input and range

※ Maximum range of display scale

    -1.999 ~ 1.999 / -19.99 ~ 19.99 / -199.9 ~ 199.9 / -1999 ~ 9999
    the displaying range of expression changes depending of the set-up location of a decimal point

Input signal

Mode

Input range

Display range Input impedance

Accuracy

AC voltage

5 V (            )

0.1 ~ 9999 Hz

0.1 ~ 9999

100 ㏀

±5 Digit max.

50 V (            )

1 ㏁

500 V (            )

5 ㏁

Comparative output action (         )

Error display code

“            ”  : This will be displayed when a measured input value exceeded max display range 
                 (9999 4digits) or when negative valve is indicated with in normal mode. Normal mode : SCH 0 or SCL 0 
“            ”  : Error message will be displayed when a setting value of High Comparative Output is less than that of  
                  Low Comparative Output
“            ”  : When input is less than min measurement range 0.1 ㎐

Parameter composition and setting method

▒ Parameter 1 (     Key - keep pushing the button(min 2 sec))

Key

set up start

Key

set up start

Key

set up start

Key

set up start

Key

set up start

Key

set up start

Key

set up start

Key

set up start

Key

set up start

Key

Key

Key

Key

Key

Key

Key

Key

Key

        

        Key

     set up

        

        Key

     set up

        

        Key

     set up

        

        Key

     set up

        

        Key

     set up

9.999

1.800 (magnification)
0.500 (magnification)

+99 (Max value error compensation)

0.1

sec

0.2

sec

0.3

sec

0.5

sec

0.8

sec

2.0

sec

2.5

sec

3.0

sec

4.0

sec

5.0

sec

1.0

sec

1.5

sec

-99 (Min value error compensation)

9.999 (Max value of high scale setting)

-1.999 (Min value of high scale setting)

9.999 (Max value of low scale setting)

-1.999 (Min value of low scale setting)

Set the position of decimal point

OFF

H-Hd

OFF

ON

L-Hd

E-Hd

99.99

999.9

9999

Default value :

Default value :

Default value :

Default value :

Default value :

Default value :

Default value :

Default value :

Default value :

        

        Key

     set up

        

        Key

     set up

        

        Key

     set up

        

        Key

     set up

9. Lock function

setting

8. Max value

auto holding

7. Set position of

a decimal point

6. Low scale setting

5. High scale setting

1. Set the input range

2. Magnification setting

3. Displayed value error

compensation

4. Display input

average value

keep pushing     key(min 2 sec) and
find the parameter 1 set up mode

To move the position of the

number then press     key

To move the position of the

number then press     key

To move the position of the

number then press     key

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

※         : This is the set-up value when input pulse frequency is within 0.1 second and this value can change if    
               the input impulse frequency exceeds 0.1 second.

shortly push the     button(below 2 sec) and find the parameter 2 set up mode

Display function of 
the max input value

Display function of 
the min input value

Set up the max 

comparative output 

value

Set up the min 

comparative output 

value

Set the comparative 
output mode

Hysteresis Selection

Key

Key

Key

 Key

set up start

 Key

set up start

 Key

set up start

 Key

set up start

Key

Key

Key

Key

    max.

value default

    min.

value default

        Key

     set up

To move the position of the

number then press     key

To move the position of the

number then press     key

To move the position of the

number then press     key

        Key

     set up

        Key

     set up

        Key

     set up 

9.999 (set up the max comparative output value)

-1.999 (set up the mix comparative output value)

9.999 (set up the max comparative output value)

-1.999 (set up the mix comparative output value)

LL.ot

99 (max. value)
00 (min. value)

HH.ot

LH.ot

HL.ot

IL.ot

Display of the max 

input value

Display of the min 

input value

set up the max 

comparative output value

set up the min 

comparative output value

Set the comparative 

output mode

Default value : 01

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

    Key

set up

completed

▒ Lock key (     Key - keep pushing the button(min 2 sec))

Key - keep pushing the button(min 2 sec)

Key

Key   

set up start

Key   

set up start

Key   

set up start

Default value :

Default value :

Set value :

Set value :

Set value :

Set value :

Set value :

Set value :

        Key

     set up

        Key로

설정값 변경

        Key로

설정값 변경

        Key

     set up

OFF

ON

    Key

set up

completed

    Key 

set up

completed

▒  Slope setting method

When users want to display 3600 (min -1999 ~ 9999) within the 1000 Hz input, setting the parameter is as follows. 
1.  Enter into the parameter 1 by pressing the      key for 2 sec
2. Set           in the             (slop high value) parameter by using shift, up and down key
3. Set     in the         (slope low value) parameter by using shift, up and down key.  
Finish the setting just like above and return to the RUN mode by pressing the menu key.  

Parameter 1

Parameter

Set value

▒ Input of peak value and hold by external input

            Detect the input peak value through the set-up of parameter or detect the displayed value by 
external pressure, or hold the displayed value by external pressure.

         
: Disuse

           
 : Hold the maximum value

          
 : Hold the minimum value

             
: Hold by external pressure

▒ Transmission function (Auxiliary output)

● All electrical current : Show the output 4 - 20 ㎃ d.c of current displayed value. (Resolution 12000)
● PNP output (Output of open collector being below 12 - 24 V d.c 50 ㎃)
● NPN output (Output of open collector being below 12 - 24 V d.c 50 ㎃)
● RELAY output (250 V a.c 5 A below) 1a × 3

Dimension and Panel cutout

102.6

▒ MP3-H

▒ MP6-H

Operation 

mode

Output operation

Explanation

H : Hysteresis

No output operation

Current indication value ≦           value,  
LO output becomes ON.             
Current indication value ≧           value, 
GO output becomes ON.
Current indication value ≧           value,   
HI output becomes ON.             
Current indication value ≦           value, 
GO output becomes ON.
Current indication value ≦            value,  

LO output becomes ON.             

Current indication value ≧            value,   

HI output becomes ON.

Current indication value ≺           ,          

GO output becomes ON.  
Current indication value ≧           value,  

LO output becomes ON.             

Current indication value ≧           value,   

HI output becomes ON.  

Current indication value ≺          and           , 

GO output becomes ON.

Same as the           operation but LO output will not 
operate under the initial setup value of          .  
It starts to operate from the next value of            .  

It does not operate under the initial

Initializing set value

Push the button                      sequancely with pushing the      .
And then            is displayed. When displaying            , push again the      button 
and the all default value is initialized.
(* Initializing set value is not available when              on.)

▒ Parameter2 (     Key -shortly push the button (below 2 sec)

※ every parameter set up is not available when the             on.

▒ How to change the parameter set value

Key - keep pushing the button(min 2 sec)

Key

Key   

set up start

Key   

set up start

Key   

set up start

Default value :

Default value :

Set value :

Set value :

Set value :

Set value :

Set value :

Set value :

        Key

     set up

        Key로

설정값 변경

        Key로

설정값 변경

        Key

     set up

OFF

ON

    Key

set up

completed

    Key 

set up

completed

1.  Pressing      key more than 2 sec within the RUN MODE will enter into the Parameter 1 and   
    pressing      key less than 2 sec will enter into the parameter 2.
2.  Able to select the parameter by pressing     ,      key and within the selected parameter, 
    parameter and set value repeatedly flickers in the display unit.
3.  Able to change the set value by pressing the      key and at this moment, set value flickers 
    in the display unit(when set value is 0, only the 0 th digit of constant value flickers and displayed)
    When changing the setting of constant value, able to perform the position shifting by using      key.
   Example)

 When set value is constant, only 0 th digit of the constant value will flicker in the display unit.  
 In order to change the value on 100 th digit, press the      key 3 times.  Each time when users press the      key, 
position of the digit will shirt to the left and selected digit will flicker in the display unit.
When setting is completed, return to the parameter mode by pressing the       key.  At this moment, flickers  the 
parameter and set value repeatedly. Able to return to the RUN mode by pressing the      key again.

Display value

Input value

Reviews: