HANYOUNG NUX MP3-4 H Series Instruction Manual Download Page 3

3

4

MF0104KE130121

 

Digital frequency meter

 

MP3-4H, MP6-4H

       

Thank you for purchasing HANYOUNG product.

        Please check whether the product is the exactly same as you ordered. 
        Before using the product, please read this instruction manual carefully.
        Please keep this manual where you can view at any time

 

1381-3, Juan-Dong, Nam-Gu Incheon, Korea.  
TEL:(82-32)876-4697 FAX:(82-32)876-4696 
http://www.hynux.net

HANYOUNGNUX CO.,LTD

HEAD OFFICE

JL.CEMPAKA BLOK F 16 NO.02 DELTA SILICON II INDUSTRIAL PARK
LIPPO CIKARANG CICAU, CIKARANG PUSAT BEKASI 17550 INDONESIA
TEL : 62-21-8911-8120~4  FAX : 62-21-8911-8126 

PT. HANYOUNG ELECTRONIC INDONESIA

INDONESIA

FACTORY

Connection diagram

● MP3-4-NH

● MP6-4-NH

▒ MP3-4-OH 

(Relay output, 4 - 20 mA Current output)

▒ MP3-4-1H 

(Relay output)

▒ MP6-4-OH 

(Relay output, 4 - 20 mA Current output)

▒ MP6-4-1H 

(Relay output)

▒ MP6-4-2H

(NPN TR, 4 - 20 mA Current output)

▒ MP6-4-3H

 (PNP TR, 4 - 20 mA Current output)

Suffix code

Model

Code

Information

MP

Digital frequency meter

Dimension

3

Dimension 96 × 48 ㎜

6

Dimension 72 × 36 ㎜

Displayable digit

4

4 digits (9999)

 Output (Optional)

N

Only for display

0

Relay output (HI, GO, LO) + Current output (4 - 20 ㎃)

1

Relay output (HI, GO, LO)

2

NPN TR output (HI, GO, LO) + Current output (4 - 20 ㎃)

3

PNP TR output (HI, GO, LO) + Current output (4 - 20 ㎃)

Measurement input signal

H

AC input frequency measurement

※ Measurement input signal is confined to MP6-4H and MP3-4H is under developed

Power supply voltage 100 - 240 V a.c 50 - 60 ㎐ allowable voltage fluctuation : 85 ~ 110 %

Power consumption 5 VA

Display method

7 Segment LED Display

Insulation resistance

100 min ㏁ (500 V d.c mega standard) between the external terminal and case

Dielectric strength

2000 V a.c for 1 min (between the external terminal and case)

Noise immunity

Square wave noise by the noise simulator pulse width 1 ㎲, ±1000 V

Vibration resistance

Malfunction 10 -55 Hz peack amplitude 0.5mm X/Y/Z each direction for 1 hour
Resistance 10 -55 Hz peack amplitude 0.5mm X/Y/Z each direction for 2 hours

Shock resistance

Malfunction 100 ㎨  X·Y·Z each direction for 3 times
Resistance 300 ㎨  X·Y·Z each direction for 3 times

Ambient temperature

-10 ~ 55 ℃ (icing or dew condensation not allowed)

Ambient humidity

35 ~ 85 % RH (without dew condensation)

Storage temperature

-20 ~ 65 ℃ (icing or dew condensation not allowed)

Relay Life span

Phisical : 20,000,000 ㎰ Min ,  Electrical : 100,000 ㎰ Min

Measurement method

Coefficient Measuring method

Display cycle

When the input period is less than 0.1 second, it displays every 0.1 second.
When the input period exceeds 0.1 second, it displays every 0.1 second.

Displayable digit

-1999 ~ 9999 (4 digits)

Measurable range

0.1 Hz - 9999 Hz

Measuring items

Frequency (Hz)

Decimal function

Selection by internal parameter

Scaling function

Displaying function of converting measured maximum value and minimum value into random figure

Hold function

External hold automatic hold of peak detection for maximum value and minimum value

Control

Hold of Displaying value

Other functions

•Comparative output                    •Max value / min value indication by the front key 
•Protect the set value from changing •Average the value and delay the display cycle       

Output (Optional)

·Relay output of contact point (3 output) 
·Current output (4 - 20 ㎃)      ·Transistor output (NPN, PNP) 

Weight

Approx. 180 g

Specification

Parameter 1

Display

Mode name Default value

Set range

Remark

Input range

0

Select the measuring range of 

input frequency.

1

2
3

Factor

Max :

Use this to get the ×(involution) 

of input reading.

Min :

Input 

compensation

Max :

Correct the error by ) or 

reducing(-) to the input reading. 

Min :

Updating 

cycle

Max :

Set up the time for measure the 

mean value of input.

Min :

High scale

Max :

Set up the maximum value 

of display when you need to 

convert into random value.

Min :

Low scale

Max :

Set up the minimum value of 

display when you need to 

convert into random value.

Min :

Position of 

decimal point

Set up the location of 

a decimal point

Hold function

Set up the autonomic holding 

when detecting PEAK value.

Use external hold (E-Ha)

Lock function

Set up the locking on function of 

panel meters

Parameter 2

Display

Mode name Default value

Set range

Remark

High Peak

Display

-

-

Display the max value 
among the measured values.

Low Peak

Display

-

-

Display the min value 
among the measured values.

Output

High Set

Max : +9999

Set up the high set value.

Min : -1999

Output

Low Set

Max : +9999

Set up the low set value.

Min : -1999

Output Type 

Select

LL(LL.ot)

Set the comparative output 
mode.

HH(HH.ot)
LH(LH.ot)
HL(HL.ot)
IL(IL.ot)

HYS terisis

Max : 99

Set up the hysteresis.

Min : 00

 INSTRUCTION MANUAL

Safety information

Before using the product, please read the safety information thoroughly and use it properly.Alerts declared in the manual 
are classified to Danger, Warning and Caution by their criticality

DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury

WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury

There is a danger of occurring electric shock in the input/output terminals so please never let your body or conductive substance is touched.

Danger

•This product does not contain an electric switch or fuse, so the user needs to install a separate electric switch 
   or fuse externally. (Fuse rating : 250 V 0.5 A)
•To prevent defection or malfunction of this product, apply a proper power voltage in accordance with the rating.
•To prevent electric shock or malfunction of product, do not supply the power until the wiring is completed.
•Since this product is not designed with explosion-protective structure, do not use it any place with flammable or explosive gas.
•Do not decompose, modify, revise or repair this product. This may be a cause of malfunction, electric shock or fire.
•Reassemble this product while the power is OFF. Otherwise, it may be a cause of malfunction or electric shock.
•If you use the product with methods other than specified by the manufacturer, there may be  bodily injuries or property damages.
•There is a possibility of occurring electric shock so please use this product after installing it onto a panel while it is operating.

Warning

•The contents of this manual may be changed without prior notification.
•Do not use this product at any place with occurring corrosive (especially noxious gas or ammonia) or flammable gas.
•Do not use this product at any place with direct vibration or impact.
•Do not use this product at any place with liquid, oil, medical substances, dust, salt or iron contents.(Use at Pollution level 1 or 2)
•Do not polish this product with substances such as alcohol or benzene. (Use neutral detergent.)
•Do not use this product at any place with a large inductive difficulty or occurring static electricity or magnetic noise.
•Do not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation.
•Install this product at place under 2,000 m in altitude.
•When the product gets wet, the inspection is essential because there is danger of an electric leakage or fire.
•If there is excessive noise from the power supply, using insulating transformer and noise filter is 
   recommended. The noise filter must be attached to a panel which is already connected to a ground 
   and the wire between the filter output side and power supply terminal must be short as possible.
•If twisting the power cables closely together then it is effective against noise.
•Do not connect anything to the unused terminals.
•After checking the polarity of terminal, connect wires at the correct position.
•When this product is connected onto a panel, use a circuit breaker or switch approved with IEC60947-1 or IEC60947-3.
•Install a circuit breaker or switch at near place for convenient use.
•For the continuous and safe use of this product, the periodical maintenance is recommended.
•Some parts of this product have limited life span, and others are changed by their usage.
•The warranty period for this product including parts is one year if this product is properly used.

Caution