▶ Error
Fig. 52) Error screen
Save the error history to the SD card.
(Not work during recording)
Initialize the error history.
(Not work during recording)
Error message
Description
[CHnn] ALARM1 ON
-
[CHnn] ALARM1 OFF
-
[CHnn] ALARM2 ON
-
[CHnn] ALARM2 OFF
-
DI1 ON
External contact input 1 (DI 1) contact ON
DI1 OFF
External contact input 1 (DI 1) contact OFF
DI2 ON
External contact input 2 (DI 2) contact ON
DI2 OFF
External contact input 2 (DI 2) contact OFF
DI3 ON
External contact input 3 (DI 3) contact ON
DI3 OFF
External contact input 3 (DI 3) contact OFF
DI4 ON
External contact input 4 (DI 4) contact ON
DI4 OFF
External contact input 4 (DI 4) contact OFF
[CHnn] SENSOR BURNOUT
-
[CHnn] RJC ERROR
Inferior input of the reference junction compensation (RJC) for the
channel
[CHnn] ADC ERROR
Inferior AD input of the channel
[CHnn] CAL ERROR
The channel is not corrected
[CHnn] INPUT CONNECTION ERROR
Not communication with the input board on the channel
I/O CONNECTION ERROR
Fail communication with the input/output board (DI/DO)
[ Error message ]
( nn : Channel number )
Check by circulating a total of 40 error histories.
The saved file name has the format of "ERR_
yymmdd.TXT". The destination folder is the
"GR200_EVNT" folder in the root directory of
the SD card.