English _
17
!
INST
ALLA
TION & CONNECTION
Connect lens module cable to lens module
1.
Unscrew the back cover by turning it counterclockwise.
J
`
Be sure to remove the back cover first and assemble/disassemble the RJ45
connector.
2.
Connect the RJ45 modular jack (female) to the RJ45 connector
(male).
3.
Assemble by rotating the RJ45 modular jack (female) and the RJ45
protection cover clockwise (Follow the arrow).
4.
Assemble by rotating RJ45 protection cover and back cover
clockwise (Follow the arrow). When the back cover is assembled,
the cable waterproof gasket is tightly attached to the cable to make
it waterproof.
J
`
You must fully assemble it to rotate the back cover up to the end of the screw thread of the RJ45 connector.
RJ45 connector
(male)
RJ45 modular
jack (female)
RJ45 connector
protection cover
Back cover
Cable aterproof
gasket
Adjust the length of the cable for connecting the lens module
The length of the cable for connecting the main unit and lens module can be adjusted. Please follow the
steps in the correct order to adjust the length of the cable for connection:
1.
Cut out the cable from the RJ12 Plug at the length you want.
2.
Peel off the sheath of the cable you cut out.
3.
Peel off the silver foil and pull it back.
4.
Straighten the colored wires in the following order.
Number
Color
1
Black
2
Red
3
Blue
4
Orange
5
White
6
Green
5.
Insert the electric wire into the end of the RJ12 PLUG provided
as an accessory.
6.
Fix the plug to the cable by using a pressing tool.
7.
After adjusting the length, remove the remaining silver shield on
the rear side of the plug.
J
`
Be sure to cut out the RJ12 Plug area to adjust the length.
`
Make sure the color and order of the wires match what is provided in the
table.
`
Check out whether the silver shield of the cable properly makes contact
with the RJ12 PLUG metal shield.