Trouble Shooting_
31
http://192.168.1.100/stw-cgi/factory.cgi?mac=00:11:22:33:44:55&sn=123456789012345
http://192.168.1.100/stw-cgi/factory.cgi?mac=00:11:22:33:44:55&sn=123456789012345
4-3 Entering Serial Number and MAC
4-3-1 Input process of MAC & Serial when replacing the NETWORK PBA
1. In the Monitoring screen enter the command in the following format in the Address box.
http://<IP Address>/stw-cgi/factory.cgi?mac=<xx:xx:xx:xx:xx:xx>&sn=<xxxxxxxxxxxxxxx>
mac: MAC address, sn: Serial number
ex) http://192.168.1.100/stw-cgi/factory.cgi?mac=00:11:22:33:44:55&sn=123456789012345
2. If the OK message appears in about 2 or 3 seconds as shown in the figure below, the entry
operation is completed normally.
Fig 4-8
Fig 4-9