Summary of Contents for Alc Smart AT8100

Page 1: ...169070 80 Fax 86 0371 67169090 Service E mail sales hwsensor com Website http www hwsensor com AT8100 HENAN HANWEI ELECTRONICS CO LTD Address No 169 Xuesong Rd National High tech Zone Zhengzhou 450001 China Service Tel 86 0371 67169070 80 Fax 86 0371 67169090 Service E mail sales hwsensor com Website http www hwsensor com HW120401146 ...

Page 2: ... POWER OFF 3 4 2 1 manual power off 3 4 2 2 power saving off 3 4 2 3 low battery power off 3 4 3 TEST 3 4 4 PRINT 3 5 TEST RECORD 4 6 SETUP 4 6 1 TIME 4 6 2 UNIT 4 6 3 PRINT 4 6 4 PASS 5 6 5 FAIL 5 6 6 OPERATOR 5 6 7 PASSWORD 5 6 8 DELETE 5 6 9 TEM SCALE 5 6 10 NEXT CAL 5 7 RECORD UPLOAD 5 8 BATTERY CHANGE 6 9 ORDINARY FAULT AND SOLUTION 6 10 PRECAUTION 6 11 ACCESSORIES 6 ...

Page 3: ...nced 16 bit low power consumption MCU Electrochemical sensor good reliability and accuracy Color LCD indication Passive test function Wireless printing function Real time and temperature indication Two level audible and visible alarm indication Low battery automatic power off function Blowing interruption and testing rejection function Unit and alarming level adjustable History record checking 200...

Page 4: ...mension l b h 122 67 31mm Weight about 120g excluding battery Table 1 Allowable error Alcohol gas concentration range C mg L Error C 0 400 0 032 mg L 0 400 C 1 000 8 C 1 000 30 Table 1 the allowable error in the process of detecting 4 Operation instruction 4 1 Power on Press the button the tester is powered on and it will make the self check automatically with a buzzer ringing the red and green in...

Page 5: ...e influenced After the analysis the screen displays concentration value and the follow several test types 1 Normal After testing finished if the testing result is under the pass level concentration value will indicate Clean 2 Pass After testing finished if the testing result reaches the pass level concentration value will indicate Pass and buzzing at the same time 3 Fail After testing finished if ...

Page 6: ...Unit Tem Scale Next Cal Input method of password press button to regulate the size of value in the password input mode change the numbers by press it every time till indicating the number you need press button to start the next number input During the process press button to cancel the number you choose press button to enter into option operational interface The original password of the tester is ...

Page 7: ...ification 6 8 Delete Input correct password in the password input mode press button and the screen indicates Delete all meanwhile press button to delete all the history records press C button to give up the deleting The screen will indicate No records and return to the main interface without history record 6 9 Tem Scale This tester possesses and the function of two temperature unit switch Press or...

Page 8: ...be used in specified conditions Long time no calibration Calibrate the tester Wrong Time Display Wrong time setup Reset the time Electromagnet misoperation No calibration for pressure sensors Calibrate pressure sensors again 10 Precaution Please read the manual carefully and follow the instruction before your testing To ensure the real testing result please wait 15 min to take the testing after dr...