Hanter HM 2088 User Manual Download Page 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hanter® Wireless Intelligent Alarm Systems - Model HM2088

 

               

 

 
12.

 

Wireless Door Chime 

13.

 

Monitoring service option

 

by Central Monitoring Station 

3.2 Features 

1.

 

Easy installation and simple operation 

2.

 

Wireless and wired compatible 

3.

 

Tampers proof system on telephone line being cut 

4.

 

Priority calling when alarm triggered 

5.

 

Real time record on Central Monitoring System   

6.

 

Press the Emergency Help Button on the Keychain Remote Control to trigger 
the siren immediately   

7.

 

Saved data will be retained when power failure 

8.

 

Identifying alarm event by phone, such as illegal entry, fire-alarm or gas leak 

9.

 

Link with Central Monitoring Station through telephone line 

10.

 

Add new accessories with Auto-Setting Code 

11.    Notified by Wireless Door Chime when there is a visitor

 

 

Part 4 –Unit Description 

 

4.1 Standard Accessories:

 

4.1.1 Control Panel 

The Control Panel is a device to receive signal from sensors, switches and 
detectors. Once signal received, it will immediately trigger the alarm via the siren 
and call the preset telephone numbers or Central Monitoring Station 
simultaneously for alarm notification. 

a

Panel Board Illustration 

                           

 

b. LED indicator light on Panel board (from left to right)

 

Away Arm

:    The LED light is on, while arming outside   

Home Arm

:    The LED light is on, while arming at home   

Alarm:

     

The LED light is on when alarm is triggered 

Power:

            The LED light is in red, when power is on and voltage is normal. 

When in orange, need to change the battery 

               

‹

 P.  5 

 

Hanter® Wireless Intelligent Alarm Systems - Model HM2088

                     

 

6.5   Wireless  Gas Leak Detector

 

a. Install the detector per the density of gas. 

For the Natural gas and piping coal gases lighter than air, install it close to the ceiling 

(lower 0.3~1.2meters).   
For the liquefied petroleum gases which is heavier than air, install it close to the 
floor (higher than 0.3 to 1.2 meters and inside the range of gas source with direct 
1.5meters). 

b. The detector should not be located near any areas that emit gas (cooking area). 

 

c. The detector should not be located close to any obstacles (curtain or cabinet etc.) 
d. The detector should not be located in the bathroom or any area with too much 

vapor. 

 

6.6   Coding/  Pairing 

The accessories have been coded with the Control Panel and it is ready to be used 
directly. The Coding/pairing function is only applicable for additional or new Keychain 
Remote control, Door Switches, Motion Sensors and other accessories. 

a.

 Keychain Remote Control 

Step 1:  Press the Disarm “

” key of the existing Keychain Remote Control, the 

Control Panel entered disarm status 

Step 2:    Press the “Code” button at Control Panel 
Step 3:    The Control Panel will emit a “du” sound and release the button 

Step 4:  Press the 

” key of the new Keychain Remote Control 

Step 5:  The Control Panel will emit a 5 “du” sound to acknowledge the coding 

successful

 

Step 6:  Continue the Step 4 & Step 5 for the rest of the new Keychain Remote 

Controls 

Step 7:    Exit from Coding program by press the key of 

”chain Remote Control 

 

b. Door Switches, motion sensors and other accessorie

Step 1:  Press the Disarm “

” key of the existing Keychain Remote Control, the 

Control Panel entered disarm status 

Step 2:    Press the “Code” button at Control Panel 
Step 3:    The Control Panel will emit a “du” sound and release the button 
Step 4:    On or activate the Door Switches, Motion Sensors and other accessories one 

by one 

Step 5:  The Control Panel will emit a 5 “du” sound to acknowledge the coding 

successful 

Step 6:    Exit from Coding program by press the key of

 

”chain Remote Control 

 

6.7 Transmitter Erasing 

If you want to erase of all the transmitters (including all sensors and detectors), you 
need to cut power and pressing and holding the “Code” button on the Control Panel at 
first and then connect the

 

power plug, when hear “du” voice, release the

 

“Code” button, 

and the transmitters are erased successfully.

 

 

‹

    P.    16

 

 

Summary of Contents for HM 2088

Page 1: ...rs and detectors must be placed or installed under stable condition 9 3 The Control Panel switches sensors and detectors are not advisable to be placed or installed at the area with heavy magnetic int...

Page 2: ...of the detector is different from Control Panel Make sure both detector and Control Panel is same frequency The coding chips of detector is not compatible with Control Panel Make sure the coding chips...

Page 3: ...the preset telephone numbers to call for help The alarm system will guard your home when you are away or resting P 3 Hanter Wireless Intelligent Alarm Systems Model HM2088 Item Issues Possible Cause...

Page 4: ...quency 315MHz 0 2MHz Operating Temperature 10 C 55 C Dimension 144x143x43mm Relative humidity 95 Part 8 Trouble Shooting Item Issues Possible Cause Solution 1 Telephone line is in working condition bu...

Page 5: ...r than 0 3 to 1 2 meters and inside the range of gas source with direct 1 5meters b The detector should not be located near any areas that emit gas cooking area c The detector should not be located cl...

Page 6: ...odel HM2088 6 2 Wireless Door Window Magnet Switch The Door Window Magnet Switch is equipped with a magnet bar Movement of the magnet triggers an internal sensor in the switch We recommend locating th...

Page 7: ...me process for the 2nd set preset number and end with 2 The rest are the same except for signing off with 3 and 4 respectively after each entry 1 is memory No 1 2 is memory No 2 and so on Note With th...

Page 8: ...try of telephone number press to exit and reset 5 1 2 Password setting The default password is 1234 you may change this password according to the following steps Step 1 Press key of the Keychain Remot...

Page 9: ...s to allow the user to have enough time to leave the monitored or detected compound The Away Arm LED will light after 30 seconds a Operate by Keychain Remote Control Press of the Keychain Remote Contr...

Page 10: ...Hanter Wireless Intelligent Alarm Systems Model HM2088 5 2 6 Anti cut During armed status when the telephone line is cuts the Control Panel will auto matically trigger the siren Note This feature will...