1. Safety Summary 

 

Please  Review the following safety precautions to avoid injury and 
prevent damage to this product or any products connected to it. 

 

Use proper AC adapter.

 

Use only the AC adapter specified for this 

product. 

 

Connect and disconnect properly. 

Connect the probe output to the 

measurement instrument before connecting the probe to the circuit under 
test. Disconnect the probe input from the circuit under test before 
disconnecting the probe from the measurement instrument. 
Do not connect or disconnect probes while they are connected to a 
voltage source. 

 

Ground the product.

 

This product is indirectly grounded through the 

grounding conductor of the mainframe power cord. To avoid electric 
shock, the grounding conductor must be connected to earth ground. 
Before making connections to the input or output terminals of the 
product, ensure that the product is properly grounded. 

 

Do not operate without covers. 

Do not operate this product with covers 

or panels removed. 

 

Power disconnect. 

The power cord disconnects the product from the 

power source. Do not block the power cord; it must remain accessible to 
the user at all times. 

 

Do not operate in an explosive atmosphere. 

 

Do not operate in wet/damp conditions. 

 
 

Summary of Contents for HT8000 Series

Page 1: ...HT8000 Series High Voltage Isolating Probes Instruction Manual Qingdao Hantek Electonics Co Ltd...

Page 2: ...1 HT8000 Series High Voltage Isolating Probes Instruction Manual Please read the instruction manual carefully to avoid injury and prevent damage to this product Ver 2 01 2022 11 16...

Page 3: ...a replacement in exchange for the defective product Parts modules and replacement products used by Hantek for warranty work may be new or reconditioned to like new performance All replaced parts modu...

Page 4: ...able of contents 1 Safety Summary 4 2 Brief Introduction 5 3 Main Specification 6 4 Unpacking and Preparation for Use 8 5 General View of Product 9 6 General View of Accessories 10 7 Operating Basics...

Page 5: ...sconnect probes while they are connected to a voltage source Ground the product This product is indirectly grounded through the grounding conductor of the mainframe power cord To avoid electric shock...

Page 6: ...C peak AC accordingly HT8000 Series high voltage isolating probe has over range alarm function It indicates with a red LED HT8000 Series high voltage isolating probe is small and robust It has very hi...

Page 7: ...ce Between each input to ground 4M Between inputs 8M Input capacitance Between each input to ground 7pF Between inputs 3 5pF Maximum measurable differential voltage 1 50 130V DC peak AC 1 500 1300V DC...

Page 8: ...echanical specification Input cable length HT8050 60cm HT8100 30cm Output cable length 90cm Alligator clips 85 40 13 mm Pincer clips 160 45 13 mm Probe body 120 55 24 mm Weight probe only 160g Environ...

Page 9: ...Instruction manual 1pcs AC adapter 1pcs Red alligator clip 1pcs Black alligator clip 1pcs Red pincer clip 1pcs Black pincer clip 1pcs 4 2 Preparation for use Please check the line voltage prior to con...

Page 10: ...9 5 General View of Product...

Page 11: ...View of Accessories HT8000 Series high voltage isolating probe includes following accessories An AC adapter a couple of alligator clips and a couple of pincer clips 1 AC adapter 2 Alligator clips 3 P...

Page 12: ...probe power input connector The green POWER indicator lights e Select adapt attenuation range according to measured voltage When the measured voltage is over range the red OVER RANGE indicator lights...

Page 13: ...ld be lower than 10MHz Otherwise the errors will be larger c The probe and measuring instrument should warm up for 20 minutes if want to get high accuracy measuring result 7 3 Troubleshooting The Powe...

Reviews: