Summary of general safety matters                                                                                               

General Safety Summary 

Read the following safety precautions carefully to avoid injury and prevent damage to this 
product or any product connected to this product. To avoid possible danger, be sure to use 
this product as specified. 

Avoid fire and personal injury. 

Only professionally authorized personnel should perform repairs. 

Use the correct power cord. 

Use only the power cord specified for this product in your country. 

Connect and disconnect properly. 

Select the correct AC power input gear and input the AC voltage within its allowable range. 
Please turn off the power before connecting to the output terminal. Before powering off the 
instrument, disconnect the load it carries and then power off. 

Ground the product. 

To avoid electric shock, the product is grounded through the grounding conductor of the 
power cord. The grounding conductor must be connected to ground. Before connecting the 
input or output of the product, be sure to ground the product properly. 

View all terminal ratings. 

To avoid fire or the impact of excessive current, check all ratings and markings on the 
product. Please consult the product manual for details on ratings before connecting the 
product. 

Use proper overvoltage protection. 

Make sure that no over voltages (such as those caused by lightning) reach the product. 
Otherwise, the operator may be exposed to electric shock. 

Do not open the cover. 

Do not operate the product with the cover or panel open. 

Maintain proper ventilation. 

Poor ventilation will increase the temperature of the instrument and cause damage to the 
instrument. Good ventilation should be maintained during use, and the vents and fans 
should be checked regularly. 

Use a suitable fuse. 

Summary of Contents for HDP4000 Series

Page 1: ...User Manual HDP43XX 44XX Series programmable DC power supply V 1 1...

Page 2: ...nt is infallible Please make sure that the specifications of relevant technical documents used are the latest and valid version yourself before using this product If you require the cooperation of pro...

Page 3: ...B Please contact the local office directly under Qingdao Hantek Electronic Co Ltd C Please contact the headquarters of Qingdao Hantek Electronic Co Ltd Contact Method of our company Qingdao Hantek Ele...

Page 4: ...duct To avoid electric shock the product is grounded through the grounding conductor of the power cord The grounding conductor must be connected to ground Before connecting the input or output of the...

Page 5: ...ance of the instrument keep the product surface clean and dry Anti static protection Static electricity can cause damage to the instrument Test in an anti static area whenever possible Before connecti...

Page 6: ...nstrument Good ventilation should be maintained during use Regularly check the vents and fans Working environment Temperature During operation 0 to 50 Non operating 40 to 70 Humidity 0 to 30 95 relati...

Page 7: ...void damaging the surface of the oscilloscope or probe do not use any corrosive or chemical cleaning agents Equipment recycling Production of this equipment requires the extraction and use of natural...

Page 8: ...8 HDP43XX 44XX SERIES DC PROGRAMMABLE POWER SUPPLY INTRODUCTION 11 MODEL LIST 12 CHAPTER 1 QUICK START 13 1 Check before use 13 1 1 Check the shipping package 13 1 2 Check the whole machine 13 1 3 Ch...

Page 9: ...inhibit 25 7 Operation Mode 26 6 1 Independ 26 6 2 Series 26 6 3 Parallel 27 6 4 Tracking 27 8 Output list 27 Steps to set the output list 28 9 Data logger 30 Data record setting steps 30 10 Remote co...

Page 10: ...User Manual 10 11 5 Capture 43 12 Lock Unlock 44 CHAPTER 4 TROUBLESHOOTING 45 CHAPTER 5 PERFORMANCE INDEX 46...

Page 11: ...response and linear adjustment rate Built in Chinese and English help system Digital IO interface support trigger input output function Support SCPI programmable command control Waveform display funct...

Page 12: ...O LAN 1mV 1mA HDP4324B 3CH USB Digital I O LAN RS232 485 1mV 1mA HDP4424B 4CH USB Digital I O LAN RS232 485 1mV 1mA HDP4324S 3CH USB Digital I O LAN RS232 485 0 1mV 1 A HDP4424S 4CH USB Digital I O LA...

Page 13: ...package If you find that the packaging carton or foam protection pad is severely damaged please keep it until the whole machine and accessories pass the electrical and mechanical tests 1 2 Check the w...

Page 14: ...p on the use of the instrument 4 USB Host Used for firmware upgrade or external file saving 5 Auxiliary function soft keys Operate according to the screen display 6 Channel Button Press to select the...

Page 15: ...t and the adjustment accuracy is 1mV 1mA 13 Arrow keys Use the arrow keys to move the cursor position up down left and right 14 Numeric keypad Enter the value directly press the Enter key to confirm a...

Page 16: ...ion 1 Digital IO interface 2 USB interface 3 LAN interface 4 AC selector 5 Power jack 6 Fuse holder 7 Exhaust fan 8 4CH 4 wire output 9 Ground reference point 10 3CH 4 wire output 11 Safety lock 12 GP...

Page 17: ...voltage mode The output voltage is equal to the set voltage value The output current value is equal to the voltage setting value divided by the load resistance value If the load current exceeds the s...

Page 18: ...and current values 9 Auxiliary Menu Bar 4 2 Meter View 1 The serial number of the currently selected channel 2 Over protection status and set value 3 The output status mode of the currently selected c...

Page 19: ...corresponding tracking parameters are displayed on the tracking curve Voltage current and power are expressed as V I and P respectively 3 Recording time Display the current data recording duration 4...

Page 20: ...mber etc This series of programmable DC power supplies provide help information for any key on the front panel and any menu key You can long press any key to get help information use the up and down a...

Page 21: ...nel of the power supply before using it and the input voltage must be within the allowable range 10 of the gear position The corresponding relationship between the voltage selector on the rear panel o...

Page 22: ...le DC power supplies Output voltage and current Over protection Channel delay Output coupling Output inhibit Operation mode Output list Data logger Remote control Utility function Lock unlock 1 Output...

Page 23: ...editing 3 Turn on the output Press the On Off key to turn on the output 2 Over protection Set the overvoltage and overcurrent protection in Source Settings OV Protection If the output voltage reaches...

Page 24: ...ed Please do not entangle the sense line with the main line The voltage drop on the sense line will affect the voltage regulation of the power supply so the sense line needs to be as short as possible...

Page 25: ...t output coupling 6 Output inhibit Press Output Settings Output Inhibit to set the inhibition mode off latched or live and DIO Pin3 function Inhibit Off Inhibit input is ignored Inhibit Latched Inhibi...

Page 26: ...de the output coupling is invalid 6 1 Independ In the independent mode the channels are output independently and do not affect each other The output voltage or current is the set voltage and set curre...

Page 27: ...nnel 2 are associated with each other and the voltages track each other Changing the set voltage of either channel will change the set voltage of the other channel accordingly the current of the two c...

Page 28: ...eys to move the cursor to position and use the numeric keyboard to set the output voltage and current Press to delete press Enter to confirm and exit editing Set output dwell time The Time column is u...

Page 29: ...op Key Set the Run Stop key as the trigger source Set the DIO trigger input as the trigger source After pressing Run Stop to run the list the output is triggered by external signal changes Note that y...

Page 30: ...age current and power waveforms and data This function must be used with the external USB storage device on the front panel the waveform is displayed on the screen and the data is directly recorded to...

Page 31: ...the horizontal offset of the displayed waveform Press Offset Offset to set the offset The default horizontal time base is 5s div 3 Properties property settings Save File Path Set the file save path P...

Page 32: ...cute the recall and the waveform is immediately displayed in the record table Duration Set the data recording time 4 Auto Scale Auto configuration The system automatically adjusts the waveform display...

Page 33: ...E g OUTP On 1 Set the channel 1 output on Volt 5 1 Set the voltage of channel 1 to 5V Meas volt 1 View the output voltage value of channel 1 10 2 LAN remote control Connect the back end network port...

Page 34: ...the connection is successful open the IO software and the device will appear in the LAN list If the device does not appear you can manually add the device enter the device s IP address and protocol t...

Page 35: ...ssful connection the network port icon in the upper right corner of the main interface is displayed as follows As with USB remote control after obtaining normal communication you can use SCPI commands...

Page 36: ...other parameters remain unchanged by default Open the IO software select to add a device set the corresponding baud rate test the VISA address and click OK to add a new device As with USB remote contr...

Page 37: ...User Manual 37 10 4 GPIB remote control Utility I O Config GPIB Access GPIB Window Use the numeric keypad to set the GPIB address and press Enter to confirm...

Page 38: ...orage Select Internal the settings will be saved in the power memory Up to 10 states can be stored as State 0 State 9 You can choose whether to set it to Power on State Press Store to save this settin...

Page 39: ...ress SetPwrOn to save the settings Users can also check Set this as power on state in Store Settings to set 11 1 4 Restore default settings Press Set to Defaults to restore the default settings 11 2 I...

Page 40: ...larity is set to positive Refer to the Output List chapter to set the output list and check BOST or EOST 3 Trigger output Turn on the channel output and execute the list output Run Stop After the trig...

Page 41: ...ibit input Select Inhibit In Pin3 can be set to inhibit input Refer to the description of DIO Pin3 function in Output Inhibition Polarity Set the Pin polarity to positive or negative In input display...

Page 42: ...mands to recall the calibration program Calibration requires the use of a six and a half or seven and a half digit high precision multimeter and low accuracy of the multimeter can lead to inaccurate p...

Page 43: ...the wiring 4 Unit The unit of input data in the DMM measurement value 5 After calibration the power automatically exits the calibration interface and can be used normally after restarting Attention A...

Page 44: ...nshot file is automatically saved to the external storage device 12 Lock Unlock Long press the Lock Unlock key to lock the front panel short press this key to cancel the lock When the front panel is l...

Page 45: ...re short circuited and whether they are in good contact 3 Check whether there is a problem with the load 4 Check whether the current setting value of this gear is appropriate If it is too low you can...

Page 46: ...P44XX CH1 64V 3 2A 32V 6 4A CH2 CH3 CH4 Load Regulation of output offset Voltage 0 01 2mV Current 0 01 250 A Line Regulation of output offset Voltage 0 01 2mV Current 0 01 250 A Ripple and noise 20Hz...

Page 47: ...Maximum input power 600VA Interface USB Device 1 piece USB Host 1 piece LAN 1 piece Digital IO 1 piece RS 232 485 HDP4324B HDP4424B HDP4324S HDP4424S HDP4324SH HDP4424SH GPIB HDP4324SH HDP4424SH 4 Wir...