Hantek 1008 User Manual Download Page 52

Load 

Click “

File

” in main menu to recall saved waveform

 and

 setup

.

                                              

                  

1. 

Load Data

Load the waveform that had saved

.

2.

 Load Setup

Load the instrument that had saved

.

51

  Hantek 1008

  

DIGITAL OSCILLOSCOPE

Summary of Contents for 1008

Page 1: ...Hantek 1008 DIGITAL OSCILLOSCOPE USER SMANUAL Hantek1008...

Page 2: ...Hantek1008 0 0 Version 1 Hantek 1008 X DIGITAL OSCILLOSCOPE USER S MANUAL...

Page 3: ...ng Basics 23 The User s Interface 24 The Vertical System 30 The Horizontal System 32 The Trigger System 33 Input Connectors 35 CHAPTER 3 Understanding Function 36 Set Ocsilloscope 37 Set Vertical Syst...

Page 4: ...input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement device Observe All Terminal Ratings To avoid re or shock hazard observe all ratings a...

Page 5: ...roduction test research and design and all of the applications involving analog circuits test and troubleshooting as well as education and training In addition to the list of general features on the n...

Page 6: ...Win7 Processor Upwards of 1 00G processor Memory 256M byte Disk Space 500M disk free space Screen Resolution 800 x 600 pixel Recommended Con guration Operating System Windows XP SP3 System Processor 2...

Page 7: ...ation is complete 1 While in Windows insert the installation CD into the CD ROM drive 2 The installation should start up automatically Otherwise in Windows Explorer switch to the CD ROM drive and run...

Page 8: ...4 Choose a destination directory Click Next to continue Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 9: ..._ 5 Check the setup information Click Next to start copying les Hantek1008...

Page 10: ...7 Updating Your System Con guration 6 This Status dialog is displayed during les copying Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 11: ...XW 8 The installation is completed Hantek1008...

Page 12: ...X Install Driver 1 Connect the A Type Plug of USB cable to your PC s USB port 2 Connect the B Type Plug of USB cable to the device s USB port 3 New hardware is found D Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 13: ...XY 4 New hardware search wizard starts Hantek1008...

Page 14: ...XZ 5 Select the speci c location Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 15: ...X 6 New hardware search wizard starts to search the driver Hantek1008...

Page 16: ...X 8 The wizard has nished installation of DRIVER 7 New hardware wizard installs DRIVER Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 17: ...e rate 2 4MSa s Max memory depth 4K points Built in fast fourier transform function FFT 20 Automatic measurements Automatic cursor tracking measurements Waveform storage record and replay dynamic wave...

Page 18: ...notify the franchiser Check the instrument In case there is any mechanical damage or defect or the instrument does not operate properly or fail performance tests please notify the franchiser Probe Co...

Page 19: ...X_ Correct Compensated Over compensated Hantek1008...

Page 20: ...robe be sure the perfection of the insulated cable and do not touch the metallic portions of the probe head while it is con nected with a voltage source Function Check Perform this functional check to...

Page 21: ...n switch on the probe as 10X and connect the probe on the osci lloscope with CH1 Aim the slot in the probe connector at the faucet on BNC of CH1 and insert then turn right to lock the probe Finally at...

Page 22: ...al path for maximum measurement accuracy You can run the routine at any time but you should always run the routine if the ambient temperature changes by 5 deg or more For accurate calibra tion power o...

Page 23: ...An Auto lgnition Probes Four Test Cables A USB Cable YY Accessories All the accessories list below are standard accessories for the oscilloscope A PC software of the oscilloscope Hantek1008...

Page 24: ...YZ Chapter 2 Operating Basics The User s Interface The Menu System The Vertical System The Horizontal System The Trigger System Input Connectors Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 25: ...interface will be showed as follows In addition to displaying waveforms the display area is lled with many details about the waveform and the oscilloscope control settings 1 The Main Menu All settings...

Page 26: ...on indicates that the channel is bandwidth limited 11 The software status indicates it connected via USB no marker the channel is not displayed 4 It shows the main time base setting 5 13 A window that...

Page 27: ...Y The Menu System The Main Menu 1 File load or save data setup 2 View Change the user interface Hantek1008...

Page 28: ...Y 3 Setup Setup setting 4 Display Change wave display type 5 Cursor Set Cursor measure type 6 Measure Set measurement parameters Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 29: ...Y_ 8 Utility Utility setting 9 Window Window setting 7 Acquire Run stop or other operation setting Hantek1008...

Page 30: ...Y 11 Help Turn on help le 10 Vehicle Vehicle setting Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 31: ...Vertical System Click Setup Vertical The following gure shows the vertical parameters setting in the vertical Setup window 1 Select channel User can select the channel by clicking the Combo Box Hante...

Page 32: ...channel voltage range 5 Probe Set the Select one according to the probe attenuation factor to ensure correct vertical scale reading 6 Invert Invert the selected wave 2 ON OFF Turn on or off the selec...

Page 33: ...up Horizontal The following gure shows the horizontal parameters settings in the Horizontal System window 1 Time DIV lead the setting of the time base parameters 2 Format lead the setting of the horiz...

Page 34: ...ZZ The Trigger System Click Setup Trigger The following gure shows the trigger system control 1 Trigger Mode Sets the trigger mode Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 35: ...the trigger source to CH1 CH8 Z 3 Tirgger Source 4 Trigger Slope Select the edge trigger slope to Positive or Negative slope 2 Trigger Sweep Select the trigger sweep mode to AUTO NORMAL or SINGLE Han...

Page 36: ...r waveform display CAL Probe compensation output Other Connector USB Port Connect the B Type Plug of USB cable to this port Power Supply Built in waveform generator GND A ground terminal not installed...

Page 37: ...Z Chapter 3 Understanding Oscilloscope Functions Set Oscilloscope Set Vertical System Set Horizontal System Set Trigger System Save Load Utility Function Measure Signal Print Hantek1008...

Page 38: ...save several different setups Load Setup The oscilloscope can recall the last setup any saved setups or the factory setup before the oscilloscope software was running You can use the Load Setup menu...

Page 39: ...Channel Control Panel in sidebar The Vertical function Turn on off the channel Volt DIV Select the channel voltage div Coupling Probe Select the channel probe attenuation Invert Turn on off the invert...

Page 40: ...e the selected channel voltage in sidebar You can left click and drag the mouse on the knob to change the voltage Probe Attenuation Setting Select the attenuation factor for the probe To check the pro...

Page 41: ...yed waveform 180 degrees with respect to the ground level When the oscilloscope is triggered on the inverted signal the trigger is also inverted Click Invert in Vertical window The following picture s...

Page 42: ...X The following picture shows the waveform of inversion Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 43: ...ource A B Set the source of the math channel Operate Set operation type of the math channel Volt DIV Set the resolution of the math channel Probe Set the math channel probe attenuation Invert Turn on...

Page 44: ...tract source B from source A A B Multiply source A by source B FFT Convert a time domain signal into its frequency components spectrum Select the operate type in the Operate menu Select source A and B...

Page 45: ...om your computer Save Save the current reference waveform to your computer as rfc format Save Reference Save the current reference waveform to your computer as rfc for mat You can change the vertical...

Page 46: ...ect the saved source The Reference Waveform Display Window Note If you turn on the Reference channel the load le window will appear Click Save to save the waveform to rfc le Then a saved source window...

Page 47: ...ob can change Time DIV If the waveform acquisition is stopped Time DIV control expands or compresses the waveform Change Format Click Time DIV you can set the time base in Horizontal Setup window In t...

Page 48: ...ton to set the trigger point to the horizontal center of the screen Horizontal position changes the displayed waveform position relative to the trigger point The user can drag on screen to change the...

Page 49: ...n to occur The oscilloscope continues to ac quire enough data so that it can draw the waveform to the right of the trigger point after it detects a trigger The Edge trigger determines whether the osci...

Page 50: ...H1 Select CH1 as trigger signal CH2 Select CH2 as trigger signal CH3 Select CH3 as trigger signal CH4 Select CH4 as trigger signal Slope Set the slope to Rising or Falling Rising Trigger on rising edg...

Page 51: ...u to save data setup and image 2 Save Setup Save the current oscilloscope setup to le 3 Save Image Save the software display window in a bmp or jpg format le 1 Save Data Save waveform data as one of t...

Page 52: ...Load Click File in main menu to recall saved waveform and setup 1 Load Data Load the waveform that had saved 2 Load Setup Load the instrument that had saved 51 Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 53: ...lways run the routine if the ambient temperature changes by 5 deg or more For accurate calibra tion power on the oscilloscope and wait twenty minutes to ensure it is warmed up To compensate the signal...

Page 54: ...t setups Factory Setup in Utility menu the oscilloscope displays the CH1 The oscilloscope set up for normal operation when it is shipped from the factory and can be recalled at anytime by user The Fac...

Page 55: ...There are two languages in Language Click Language in Utility menu Language menu The default language is English 54 Hantek1008...

Page 56: ...o take measurements by moving the cursors 1 Source The user can set the source to CH1 CH2 and When you use cursors be sure to set the Source to the waveform on the display that you want to measure 2 T...

Page 57: ...t displays on status bar 2 Trace The Trace cursors appear as vertical lines on the display and measure the waveform amplitude at the point the waveform crosses the cursor 1 Cross The Cross cursors app...

Page 58: ...r measure result display on status bar 3 Vertical The Vertical cursors appear as vertical lines on the display and measure the vertical parameters The Trace cursor display window 57 Hantek 1008 DIGITA...

Page 59: ...l cursor measure result display on status bar 4 Horizontal The Horizontal cursors appear as horizontal lines on the display and measure the hori zontal parameters The Vertical cursor display window 58...

Page 60: ...sult display on status bar Measure Menu Click Measure in main menu The oscilloscope provides 20 parametric auto measurements 12 voltage and 8 time measurements The Horizontal cursor display window 59...

Page 61: ...mum Voltage of the absolute minimum level measured over the entire waveform Peak To Peak Peak to peak Max Min measured over the entire waveform Top Voltage of the statistical maximum level measured ov...

Page 62: ...100 measured over the entire waveform 3 Horizontal Period Time to take for the rst signal cycle to complete in the waveform Frequency Reciprocal of the period of the rst cycle in the waveform Rise Tim...

Page 63: ...n the 50 amplitude points 4 Clear Measure Clear all measure items on display screen The Measure Display Window Note The results of the automatic measurements will be displayed on the bottom of the scr...

Page 64: ...m Display Type Click Type in Display menu The following gure shows the type parameters setting If the Vectors type mode is selected the waveform will be displayed as following gure 63 Hantek 1008 DIGI...

Page 65: ...Display Grid Click Display in main menu If the Dots type mode is selected the waveform will be displayed as following gure 64 Hantek1008...

Page 66: ...The grid shows 65 Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 67: ...Intensity Click Display Intensity in main menu The grid not shows 66 Hantek1008...

Page 68: ...You can change the grid and waveform color intensity in this dialog The following gure shows the intensity dialog which shows the display parameters setting 67 Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 69: ...Click the black box and you can set the background color Click Grid Banckground Color in Display You can change the banckground color Grid Background Color 68 Hantek1008...

Page 70: ...t waveform 2 Click the PrintPreview in File menu to get into the Preview window window use the Zoom In button and the Zoom Out button to change the size of the waveform graph Click the Close button to...

Page 71: ...The Print report 70 Hantek1008...

Page 72: ...Chapter 4 Application Example Simple Measurement Capturing a Single Shot Signal The Application of the X Y Taking Cursor Measurement 71 Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 73: ...ollows 1 Click the Measure Horizontal Frequency button the frequency of the signal display on the bottom of the waveform interface 2 Click the Measure Vertical Peak to Peak button the Vpp of the signa...

Page 74: ...the Trigger Slope to which means you select the rising edge 5 Adjust the Volts DIV and the time base in a proper range for the signal 6 Drag the trigger level sign on the waveform display screen to pr...

Page 75: ...he switch to x10 on the probes 2 Connect the CH1 probe to the input of the circuit and connect the CH2 probe to the output of the circuit 3 Adjust the vertical scale and offset to display approximatel...

Page 76: ...Signal in X Y Format 75 Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 77: ...om the formula above arcsine A B or arcsine C D If the main axis of the ellipse is between I and III quadrant must be in the range of 0 2 or 3 2 2 If the main axis is at II and IV quadrant must be in...

Page 78: ...e of the First Sine Waveform Do these steps 1 Click Cursor Source 2 Click Cursor Type select Vertical 3 Push left mouse button and the vertical lines appear 4 Drag the mouse button to the point you wa...

Page 79: ...nt measure CH2 2 Click Cursor Type select Horizontal 3 Push left mouse button and the Horizontal lines appear 4 Drag the mouse button to the point you want to measure 5 Release the left mouse button t...

Page 80: ...n X axis in a Waveform Do these steps 1 Click Cursor Source select CH1 select CH2 if you want trace CH2 2 Click Cursor Type select Trace 3 Click the cursor at the position that you want to trace the w...

Page 81: ...Note Click Cursor Type select Cross you can measure time and amplitude at the same time Read the details showing in the status bar 80 Hantek1008...

Page 82: ...Chapter 5 Appendix Appendix A Speci cations Appendix B General Maintenance 81 Hantek 1008 DIGITAL OSCILLOSCOPE...

Page 83: ...Attenuation Factors Supported Voltage Resistance 1M DC Input Impedance 2 4MSa s Single channel Real Time Sample Input Coupling Sample Rate Sample Mode Appendix A Speci cations Speci cations Table Acq...

Page 84: ...sitive Width Frequency Period Rise Time 10 90 Vmid Vrms Vcrms Preshoot Overshoot Vp p Vmax Vmin Vmean Vamp Vtop Vbase Cross Trace Horizontal Vertical Time Measurement Voltage Auto Measure Cusor CH1 CH...

Page 85: ...evice and probes as often as operating conditions require Make sure the device disconnect from all power sources To clean the exterior surface perform the following steps 1 Remove loose dust on the ou...

Reviews: