Service Manual
6
Precautions
1-2 Servicing Precautions
WARNING : An electrolytic capacitor installed with the wrong polarity might explode.
Caution :
Before servicing instruments covered by this service manual and its supplements,
read and follow the Safety Precautions section of this manual.
Note : If unforeseen circumstances create conflict between the following servicing preautions
and any of the safety precautions, always follow the safety precautions.
1-2-1. General Servicing Precautions
1. Servicing precautions are printed on the cabinet, and should be followed closely.
2. Always unplug the unit's AC power cord from the AC power source before attempting to :
(a) remove or reinstall any component or assembly, (b) disconnect PCB plugs or connectors,
(c) connect a test component in paralled with an electrolytic capacitor.
3. Some components are raised above the printed circuit board for safety. An insulation tube or tape
is sometimes used. The internal wiring is sometimes clamped to prevent contact with thermally hot
components. Reinstall all such elements to their original position.
4. After servicing, always check that the screws, components and wiring have been correctly
reinstalled. Make sure that the portion around the serviced part has not been damaged.
5. Check the insulation between the blades of the AC plug and accessible conductive parts
(examples; metal panels, input terminals and earphone jacks)
6. Insulation Checking Procedure : Disconnect the power cord from the AC source and turn the power
switch ON. Connect an insulation resistance meter(500V) to the blades of the AC plug.
The insulation resistance between each blade of the AC plug and accessible conductive parts
(see above) should be greater than 1 megohm.
7. Always connect a test instrument's ground lead to the instrument chassis ground before connecting
the positive lead; always remove the instrument's ground lead last.
Summary of Contents for H950VI B19BF
Page 1: ...Service Manual 19Inch Viewable size 19 0 TFT LCD Analogue Color Monitor H950VI B19BF...
Page 12: ...Disassembly and Reassembly Service Manual 12 Fiqure...
Page 21: ...Service Manual 22 Electrical Parts List LOCATION NO TYPE DESCRIPTION Q ty 7 2 Combo Board...
Page 25: ...Service Manual 26 8 Block Diagram Block Diagram...
Page 26: ...27 Service Manual WIRING D IA G R A M Wiring Diagram 9 Wiring diagram...
Page 27: ...Service Manual 28 PCB Layout 10 PCB Layout 10 1 Main PCB 10 1 1 TOP View...
Page 29: ...Service Manual 30 PCB Layout 10 3 COMBO board PCB 10 3 1 TOP View...
Page 30: ...31 Service Manual PCB LAYOUT PCB Layout 10 3 2 BOTTOM View...
Page 31: ...Service Manual 32 PCB Layout 10 3 Semiconductor Lead Identification...